A two‐stream deep neural network‐based intelligent system for complex skin cancer types classification
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Medical imaging systems installed in different hospitals and labs generate images in bulk, which could support medics to analyze infections or injuries. Manual inspection becomes difficult when there exist more images, therefore, intelligent systems are usually required for real-time diagnosis. Melanoma is one of the most common and severe forms of skin cancer that begins from the cells beneath the skin. Through dermoscopic images, it is possible to diagnose the infection at the early stages. In this regard, different approaches have been exploited for improved results. In this study, we propose a two-stream deep neural network information fusion framework for multiclass skin cancer classification. The proposed technique follows two streams: initially, a fusion-based contrast enhancement technique is proposed, which feeds enhanced images to the pretrained DenseNet201 architecture. The extracted features are later optimized using a skewness-controlled moth–flame optimization algorithm. In the second stream, deep features from the fine-tuned MobileNetV2 pretrained network are extracted and down-sampled using the proposed feature selection framework. Finally, most discriminant features from both networks are fused using a new parallel multimax coefficient correlation method. A multiclass extreme learning machine classifier is used to classify lesion images. The testing process is initiated on three imbalanced skin data sets—HAM10000, ISBI2018, and ISIC2019. The simulations are performed without performing any data augmentation step in achieving an accuracy of 96.5%, 98%, and 89%, respectively. A fair comparison with the existing techniques reveals the improved performance of our proposed algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805
Tschandl, P., Rosendahl, C., & Kittler, H. (2018) · Scientific Data · doi:10.1038/sdata.2018.161 · Cited by 3,628
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855 · cited 1×
“15 The CAD system not only bypasses manual inspection, but also improves the diagnosis accuracy.”
BackgroundDiagnostic accuracy of dermoscopy
Kittler, H., Pehamberger, H., Wolff, K., & Binder, M. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00679-4 · Cited by 1,349
Codella, N., Rotemberg, V., Tschandl, P., Celebi, M. E., Dusza, S., Gutman, D., Helba, B., Kalloo, A., Liopyris, K., Marchetti, M., et al. (2019) · arXiv · doi:10.48550/arxiv.1902.03368 · Cited by 984
AI in Medical Imaging Informatics: Current Challenges and Future Directions
Panayides, A. S., Amini, A., Filipovic, N. D., Sharma, A., Tsaftaris, S. A., Young, A., Foran, D., Do, N., Golemati, S., Kurc, T., et al. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2991043 · Cited by 713 · cited 1×
“16,17 The CAD system for this specific purpose involves two building blocks: lesion segmentation and lesion classification.”
MethodA Convolutional Neural Network Framework for Accurate Skin Cancer Detection
Thurnhofer-Hemsi, K., & Domínguez, E. (2021) · Neural Processing Letters · doi:10.1007/s11063-020-10364-y · Cited by 157
A Robust Interpretable Deep Learning Classifier for Heart Anomaly Detection Without Segmentation
Dissanayake, T., Fernando, T., Denman, S., Sridharan, S., Ghaemmaghami, H., & Fookes, C. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3027910 · Cited by 105 · cited 1×
“Therefore, a computer ‐ aided diagnosis (CAD) system is always required for a second opinion in the area of medical imaging 13,14 but especially for the dermatologists to support their decision.”
MethodUse of photographs illustrating ABCDE criteria in skin self-examination
Robinson, J. K., & Ortiz, S. (2009) · Archives of Dermatology · doi:10.1001/archdermatol.2008.604 · Cited by 19
Cited by
Zhang, L., Zhang, J., Gao, W., Bai, F., Li, N., & Ghadimi, N. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105858 · Cited by 164
Melarkode, N., Srinivasan, K., Qaisar, S. M., & Plawiak, P. (2023) · Cancers · doi:10.3390/cancers15041183 · Cited by 144
Hussain, M., Khan, M. A., Damaševičius, R., Alasiry, A., Marzougui, M., Alhaisoni, M., & Masood, A. (2023) · Diagnostics · doi:10.3390/diagnostics13182869 · Cited by 58
Self-citationReview on enhancing clinical decision support system using machine learning
Masood, A., Naseem, U., Rashid, J., Kim, J., & Razzak, I. (2024) · CAAI Transactions on Intelligence Technology · doi:10.1049/cit2.12286 · Cited by 14
Metadata
- Authors
- Attique Khan, M., Sharif, M., Akram, T., Kadry, S., & Hsu, C.
- Venue
- International Journal of Intelligent Systems
- Publisher
- Wiley
- Published
- 2021-10-06
- Volume
- 37
- Issue
- 12
- Pages
- 10621-10649
- ISSN
- 0884-8173 (ISSN-L)
- 1098-111X
- OpenAlex
- W3207421495
- Cited by
- 121
- References
- 9
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.