CoChat

Comparative Evaluation of Serologic Tests for Celiac Disease: A European Initiative Toward Standardization

Open access
Stern, Martin, Working Group on Serologic Screening for Celiac Disease · 2000 · Journal of Pediatric Gastroenterology and Nutrition
Cited by 151

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Serologic methods have been used widely to test for celiac disease and have gained importance in diagnostic definition and in new epidemiologic findings. However, there is no standardization, and there are no reference protocols and materials. Methods: The European working group on Serological Screening for Celiac Disease has defined robust noncommercial test protocols for immunoglobulin (Ig)G and IgA gliadin antibodies and for IgA autoantibodies against endomysium and tissue transglutaminase. Standard curves were linear in the decisive range, and intra‐assay variation coefficients were less than 5% to 10%. Calibration was performed with a group reference serum. Joint cutoff limits were used. Seven laboratories took part in the final collaborative study on 252 randomized sera classified by histology (103 pediatric and adult patients with active celiac disease, 89 disease control subjects, and 60 blood donors). Results: IgA autoantibodies against endomysium and tissue transglutaminase rendered superior sensitivity (90% and 93%, respectively) and specificity (99% and 95%, respectively) over IgA and IgG gliadin antibodies. Tissue transglutaminase antibody testing showed superior receiver operating characteristic performance compared with gliadin antibodies. The κ values for interlaboratory reproducibility showed superiority for IgA endomysium (0.93) in comparison with tissue transglutaminase antibodies (0.83) and gliadin antibodies (0.82 for IgG, 0.62 for IgA). Conclusions: Basic criteria of standardization and quality assessment must be fulfilled by any given test protocol proposed for serologic investigation of celiac disease. The working group has produced robust test protocols and reference materials available for standardization to further improve reliability of serologic testing for celiac disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/j.1536-4801.2000.tb07174.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 151

Metadata

Authors
Stern, M., & Working Group on Serologic Screening for Celiac Disease
Venue
Journal of Pediatric Gastroenterology and Nutrition
Publisher
Wiley
Published
2000-11
Volume
31
Issue
5
Pages
513-519
ISSN
  • 0277-2116 (ISSN-L)
  • 1536-4801
OpenAlex
W2130800600
Cited by
151
References
1
FWCI
14.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.