Reading and Eye Movements in Age-Related Maculopathy
The DOI matches its OpenAlex record.
Abstract
Reading characteristics were studied in age-related maculopathy (ARM) by monitoring eye movement patterns as subjects read word charts and text charts that contain a wide range of print sizes. Eye movements were monitored with an infrared scleral reflection device and subjects were tested over a wide range of chart luminances. In normal subjects, as print size approaches threshold, reading speed slows mainly because of a decrease in fixation rate, whereas regressive saccades remain infrequent. There is little change in the ratio of number of letters read per forward saccade. With decreased luminance, there is a decreased reading acuity but the relation between reading speed and the size of print relative to the threshold size remains relatively constant. Subjects with ARM show similar fixation rates to normals, but they average fewer letters per forward saccade and make more frequent regressions. ARM subjects are more likely to have reading performance strongly affected by luminance. The number of letters per forward saccade can show a strong dependence on luminance, whereas fixation rates remain relatively unchanged. It is proposed that reduced reading performance in ARM is predominantly the result of a reduced perceptual span, with poor oculomotor control playing a secondary role. Optimal print size may be best predicted from letter chart acuity (r = 0.70) or word reading acuity (r = 0.69). Word reading acuity is the best predictor of peak reading speed (r = -0.74), whereas peak reading speed is poorly correlated with contrast sensitivity (r = 0.26) and scotoma area (r = -0.42).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Eye movements in reading and information processing: 20 years of research
Rayner, K. (1998) · Psychological Bulletin · doi:10.1037/0033-2909.124.3.372 · Cited by 7,979
Eye movements in reading and information processing.
Rayner, K. (1978) · Psychological Bulletin · doi:10.1037//0033-2909.85.3.618 · Cited by 1,119
Legge, G. E., Mansfield, J. S., & Chung, S. T. L. (2001) · Vision Research · doi:10.1016/s0042-6989(00)00295-9 · Cited by 642
Crowding and eccentricity determine reading rate
Pelli, D. G., Tillman, K. A., Freeman, J., Su, M., Berger, T. D., & Majaj, N. J. (2007) · Journal of Vision · doi:10.1167/7.2.20 · Cited by 380
Standardized Assessment of Reading Performance: The New International Reading Speed Texts IReST
Trauzettel-Klosinski, S., & Dietz, K. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8284 · Cited by 352
Chung, S. T. L., Mansfield, J. S., & Legge, G. E. (1998) · Vision Research · doi:10.1016/s0042-6989(98)00072-8 · Cited by 285
Preferred Retinal Locus Development in Patients with Macular Disease
Crossland, M. D., Culham, L. E., Kabanarou, S. A., & Rubin, G. S. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.03.027 · Cited by 263
Psychophysics of reading—XVI. The visual span in normal and low vision
Legge, G. E., Ahn, S. J., Klitz, T. S., & Luebker, A. (1997) · Vision Research · doi:10.1016/s0042-6989(97)00017-5 · Cited by 259
Visual function and dysfunction in early and late age-related maculopathy
Hogg, R. E., & Chakravarthy, U. (2006) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2005.11.002 · Cited by 182
The case for the visual span as a sensory bottleneck in reading
Legge, G. E., Cheung, S.-H., Yu, D., Chung, S. T. L., Lee, H.-W., & Owens, D. P. (2007) · Journal of Vision · doi:10.1167/7.2.9 · Cited by 160
Improving Reading Speed for People with Central Vision Loss through Perceptual Learning
Chung, S. T. L. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6034 · Cited by 159
Simulating prosthetic vision: II. Measuring functional capacity
Chen, S. C., Suaning, G. J., Morley, J. W., & Lovell, N. H. (2009) · Vision Research · doi:10.1016/j.visres.2009.07.003 · Cited by 59
“In a study involving low vision patients, the optimal print size for reading was best predicted from LA threshold estimates, and the word reading acuity was the best predictor for peak reading speed (Bullimore & Bailey, 1995).”
Metadata
- Authors
- Bullimore, M. A., & Bailey, I. L.
- Venue
- Optometry and Vision Science
- Publisher
- Lippincott Williams & Wilkins
- Published
- 1995-02-01
- Volume
- 72
- Issue
- 2
- Pages
- 125-138
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W1999627444
- Cited by
- 209
- References
- 0
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.