A Method to Predict Refractive Errors from Wave Aberration Data
The DOI matches its OpenAlex record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
We explored the impact of the eye's higher-order aberrations on subjective refraction comparing two classes of methods for estimating refractive state, one based directly on the wave aberration defined in the pupil plane and another based on the retinal image plane. The method defined in the pupil plane chose the sphere and cylinder that either minimized the wave aberration root mean square or minimized the sum of all the spherical and cylindrical components in the wave aberration. The method defined in the image plane chose the sphere and cylinder that optimized an image-quality metric such as the Strehl intensity ratio, the entropy and the intensity variance of the point-spread function, the volume under the modulation transfer function, or the volume under the contrast-sensitivity function. All these methods were compared in a population of six eyes for which we measured both the wave aberration with a Shack-Hartmann wavefront sensor and the subjective refraction under identical conditions. Pupil plane methods predicted subjective refraction poorly. The mean absolute error of the prediction, in spherical equivalent, was about 0.5 D (range, 0.1 to 0.8 D) and increased with increases in higher-order aberrations. However, for all the retinal image plane methods, the mean error between predicted and subjective refraction was about 0.1 D (range, 0 to 0.25 D). The reliability of the method based on the image-quality optimization was further confirmed in a large population of 146 eyes. In conclusion, higher-order aberrations influence the amount of sphere and cylinder required to correct vision. The results indicate that subjective refraction can be predicted from the eye's optics alone by optimizing computed retinal image quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards for Reporting the Optical Aberrations of Eyes
Thibos, L. N., Applegate, R. A., Schwiegerling, J. T., Webb, R., & Members, V. S. T. (2000) · Vision Science and its Applications · doi:10.1364/vsia.2000.suc1 · Cited by 824
Aberrations and retinal image quality of the normal human eye
Liang, J., & Williams, D. R. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002873 · Cited by 764
Monochromatic aberrations of the human eye in a large population
Porter, J., Guirao, A., Cox, I. G., & Williams, D. R. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001793 · Cited by 711
Self-citationTurner, R. P., Jared, D. A., Johnson, K. M., Crossland, W. A., Birch, M. J. H., Vass, D., & Underwood, I. (1990) · Cited by 580
Contribution of the cornea and internal surfaces to the change of ocular aberrations with age
Artal, P., Berrio, E., Guirao, A., & Piers, P. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.000137 · Cited by 494
Self-citationA subjective method for the measurement of monochromatic* aberrations of the eye
Howland, H. C., & Howland, B. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.001508 · Cited by 379
Aliasing in human foveal vision
Williams, D. R. (1985) · Vision Research · doi:10.1016/0042-6989(85)90113-0 · Cited by 277
Average optical performance of the human eye as a function of age in a normal population.
Guirao, A., González, C., Redondo, M., Geraghty, E., Norrby, S., & Artal, P. (1999) · PubMed · Cited by 274
Self-citationObjective technique for the determination of monochromatic aberrations of the human eye
Walsh, G., Howland, H. C., & Charman, W. N. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000987 · Cited by 220
Visibility of interference fringes near the resolution limit
Williams, D. R. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001087 · Cited by 139
Visual instrument image quality metrics and the effects of coma and astigmatism
Mouroulis, P. Z., & Zhang, H. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.000034 · Cited by 28
Effect of monochromatic aberrations on photorefractive patterns
Campbell, M. C. W., Bobier, W. R., & Roorda, A. (1995) · Journal of the Optical Society of America A · doi:10.1364/josaa.12.001637 · Cited by 24
Some entropic aspects of optical diffraction imagery
Barakat, R. G. (1998) · Optics Communications · doi:10.1016/s0030-4018(98)00471-4 · Cited by 7
Cited by
Accuracy and precision of objective refraction from wavefront aberrations
Thibos, L. N., Hong, X., Bradley, A., & Applegate, R. A. (2004) · Journal of Vision · doi:10.1167/4.4.9 · Cited by 570
Metrics of optical quality derived from wave aberrations predict visual performance
Marsack, J. D., Thibos, L. N., & Applegate, R. A. (2004) · Journal of Vision · doi:10.1167/4.4.8 · Cited by 341
Predicting subjective judgment of best focus with objective image quality metrics
Cheng, X., Bradley, A., & Thibos, L. N. (2004) · Journal of Vision · doi:10.1167/4.4.7 · Cited by 255
Optical Quality and Depth-of-field of Eyes Implanted With Spherical and Aspheric Intraocular Lenses
Marcos, S., Barbero, S., & Jiménez-Alfaro, I. (2005) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20050501-05 · Cited by 213
Wavefront-optimized ablation profiles: Theoretical background
Mrochen, M., Donitzky, C., Wüllner, C., & Löffler, J. (2004) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.01.026 · Cited by 209
Metadata
- Authors
- Guirao, A., & Williams, A.
- Venue
- Optometry and Vision Science
- Publisher
- Lippincott Williams & Wilkins
- Published
- 2003-01-01
- Volume
- 80
- Issue
- 1
- Pages
- 36-42
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2107146669
- Cited by
- 162
- References
- 13
- FWCI
- 9.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.