CoChat

Optical Quality and Depth-of-field of Eyes Implanted With Spherical and Aspheric Intraocular Lenses

Open access
Marcos, Susana, Barbero, Sergio, Jiménez-Alfaro, Ignacio · 2005 · Journal of Refractive Surgery
Cited by 213

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

PURPOSE: To compare experimental optical performance in eyes implanted with spherical and aspheric intraocular lenses (IOLs). METHODS: Corneal, total, and internal aberrations were measured in 19 eyes implanted with spherical (n=9) and aspheric (n=10) IOLs. Corneal aberrations were estimated by virtual ray tracing on corneal elevation maps, and total aberrations were measured using a second -generation laser ray tracing system. Corneal and total wave aberrations were fit to a Zernike polynomial expansion. Internal aberrations were measured by subtracting corneal from total wave aberrations. Optical performance was evaluated in terms of root-meansquare (RMS) wavefront error and Strehl ratio (estimated from the modulation transfer function). Depth-of-field was obtained from through-focus Strehl estimates from each individual eye. RESULTS: Corneal aberrations increased after I OL implantation, particularly astigmatism and trefoil terms. Third and higher order RMS (and the corresponding Strehl ratio) were significantly better in eyes with aspheric IOLs than with spherical IOLs; however, this tendency was reversed when astigmatism was included. Spherical aberration was not significantly different in eyes with aspheric IOLs, whereas it was significantly positive in eyes with spherical IOLs. Third order aberrations were not significantly different across groups. Depth-of-field was significantly larger in eyes with spherical IOLs. Spherical IOLs showed better absolute optical quality in the presence of negative defocus > 1.00 D. CONCLUSIONS: Our study shows a good degree of compensation of the corneal spherical aberration in eyes implanted with aspheric IOLs, as opposed to eyes implanted with spherical IOLs. Other sources of optical degradation, both with aspheric and spherical IOLs, are non-symmetric preoperative corneal aberrations, incision-induced aberrations, and third order internal aberrations. Although best corrected optical quality is significantly better with aspheric IOLs, tolerance to defocus tended to be lower. [J Refract Surg. 2005;21:223-235.]

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3928/1081-597x-20050501-05

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 213

Metadata

Authors
Marcos, S., Barbero, S., & Jiménez-Alfaro, I.
Venue
Journal of Refractive Surgery
Publisher
SLACK, Inc.
Published
2005-05
Volume
21
Issue
3
Pages
223-235
ISSN
  • 1042-962X (ISSN-L)
  • 1081-597X
OpenAlex
W137082989
Cited by
213
References
20
FWCI
14.26
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optical Quality and Depth-of-field of Eyes Implanted With Spherical and Aspheric Intraocular Lenses. https://app.cochat.ai/papers/10.3928/1081-597x-20050501-05
The paper
Marcos, S., Barbero, S., & Jiménez-Alfaro, I. (2005). Optical Quality and Depth-of-field of Eyes Implanted With Spherical and Aspheric Intraocular Lenses. Journal of Refractive Surgery. https://doi.org/10.3928/1081-597x-20050501-05

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.