Optical Quality and Depth-of-field of Eyes Implanted With Spherical and Aspheric Intraocular Lenses
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare experimental optical performance in eyes implanted with spherical and aspheric intraocular lenses (IOLs). METHODS: Corneal, total, and internal aberrations were measured in 19 eyes implanted with spherical (n=9) and aspheric (n=10) IOLs. Corneal aberrations were estimated by virtual ray tracing on corneal elevation maps, and total aberrations were measured using a second -generation laser ray tracing system. Corneal and total wave aberrations were fit to a Zernike polynomial expansion. Internal aberrations were measured by subtracting corneal from total wave aberrations. Optical performance was evaluated in terms of root-meansquare (RMS) wavefront error and Strehl ratio (estimated from the modulation transfer function). Depth-of-field was obtained from through-focus Strehl estimates from each individual eye. RESULTS: Corneal aberrations increased after I OL implantation, particularly astigmatism and trefoil terms. Third and higher order RMS (and the corresponding Strehl ratio) were significantly better in eyes with aspheric IOLs than with spherical IOLs; however, this tendency was reversed when astigmatism was included. Spherical aberration was not significantly different in eyes with aspheric IOLs, whereas it was significantly positive in eyes with spherical IOLs. Third order aberrations were not significantly different across groups. Depth-of-field was significantly larger in eyes with spherical IOLs. Spherical IOLs showed better absolute optical quality in the presence of negative defocus > 1.00 D. CONCLUSIONS: Our study shows a good degree of compensation of the corneal spherical aberration in eyes implanted with aspheric IOLs, as opposed to eyes implanted with spherical IOLs. Other sources of optical degradation, both with aspheric and spherical IOLs, are non-symmetric preoperative corneal aberrations, incision-induced aberrations, and third order internal aberrations. Although best corrected optical quality is significantly better with aspheric IOLs, tolerance to defocus tended to be lower. [J Refract Surg. 2005;21:223-235.]
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards for Reporting the Optical Aberrations of Eyes
Thibos, L. N., Applegate, R. A., Schwiegerling, J. T., Webb, R., & Members, V. S. T. (2000) · Vision Science and its Applications · doi:10.1364/vsia.2000.suc1 · Cited by 824
A New Intraocular Lens Design to Reduce Spherical Aberration of Pseudophakic Eyes
Holladay, J. T., Piers, P. A., Koranyi, G., van der Mooren, M., & Norrby, N. E. S. (2002) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20021101-04 · Cited by 560
Contribution of the cornea and internal surfaces to the change of ocular aberrations with age
Artal, P., Berrio, E., Guirao, A., & Piers, P. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.000137 · Cited by 494
Moreno-Barriuso, E., Lloves, J. M., Marcos, S. C., Navarro, R., Llorente, L., & Barbero, S. (2001) · PubMed · Cited by 475
Self-citationNon-linear projection of the retinal image in a wide-angle schematic eye.
Drasdo, N., & Fowler, C. W. (1974) · British Journal of Ophthalmology · doi:10.1136/bjo.58.8.709 · Cited by 301
Age-related changes in monochromatic wave aberrations of the human eye.
McLellan, J. S., Marcos, S. C., & Burns, S. A. (2001) · PubMed · Cited by 293
Self-citationAberrations and Visual Performance Following Standard Laser Vision Correction
Marcos, S. C. (2001) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20010901-19 · Cited by 289
Self-citationOptical response to LASIK surgery for myopia from total and corneal aberration measurements.
Marcos, S. C., Barbero, S., Llorente, L., & Merayo-Llovés, J. (2001) · PubMed · Cited by 282
Self-citationThe depth-of-field of the human eye from objective and subjective measurements
Marcos, S. C., Moreno-Barriuso, E., & Navarro, R. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00317-4 · Cited by 253
Self-citationRelationship between Refractive Error and Monochromatic Aberrations of the Eye
Cheng, X., Bradley, A. T., Hong, X., & Thibos, L. N. (2003) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2003.tb01589.x · Cited by 219
Cited by
Comparison of visual performance with an aspheric intraocular lens and a spherical intraocular lens
Thiagarajan, M., McClenaghan, R., & Anderson, D. F. (2011) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2011.05.046 · Cited by 19
Metadata
- Authors
- Marcos, S., Barbero, S., & Jiménez-Alfaro, I.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 2005-05
- Volume
- 21
- Issue
- 3
- Pages
- 223-235
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W137082989
- Cited by
- 213
- References
- 20
- FWCI
- 14.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical Quality and Depth-of-field of Eyes Implanted With Spherical and Aspheric Intraocular Lenses. https://app.cochat.ai/papers/10.3928/1081-597x-20050501-05
- The paper
- Marcos, S., Barbero, S., & Jiménez-Alfaro, I. (2005). Optical Quality and Depth-of-field of Eyes Implanted With Spherical and Aspheric Intraocular Lenses. Journal of Refractive Surgery. https://doi.org/10.3928/1081-597x-20050501-05
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.