Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.

Measurement of Refractive State and Deprivation Myopia in Two Strains of Mice

Frank Schaeffel, Eva Burkhardt, Howard C. Howland, Robert W. Williams·2004·Optometry and Vision Science

Abstract

PURPOSE: The mouse eye has a bright retinal image (f/number <1) but low optical quality (visual acuity about 0.5 cpd) that may render emmetropization unnecessary. However, this species is potentially a powerful model to study eye growth and myopia because its genome can be readily manipulated and has been completely sequenced. We have investigated how precisely eyes of mice can be refracted and tested whether deprivation myopia can be induced by frosted diffusers. METHODS: An automated eccentric infrared photorefractor was adapted to refract eyes of two mouse strains--C57BL/6 (B6) and DBA/2 (D2)--during Tropicamide cycloplegia without anesthesia. Axial lengths were measured in highly magnified video images of freshly excised eyes. Plastic hemispherical diffusers were applied between postnatal days and 29 and left attached for 7 or 14 days. RESULTS: (1) Trial lenses ranging from +10 to -10 D produced high correlations between the brightness slope in the pupil and applied lens power (r = 0.81 and r = 0.87), demonstrating reliable refraction. Five repeated measures in 12 eyes showed an average standard deviation of 3.0 D, equivalent to an axial length change <10 microm (derived from schematic eye modeling). (2) Deprivation produced a significant shift toward myopia, relative to untreated eyes, but only after 14 days and only in B6 mice (p = 0.02 with or p = 0.00038 without one outlier; N = 9). In contrast, DBA/2J were unaffected by occlusion, perhaps due to mutations that target eye, lens, or anterior segment. (3) Both eyes of untreated animals often had axial lengths that differed markedly. Surprisingly, we detected no significant correlation between refractive error and axial length after treatment. CONCLUSIONS: The infrared refraction technique is sufficiently sensitive to resolve equivalent changes in axial length of only +/- 10 microm in alert mice. Prolonged occlusion produces a significant myopic shift in B6 mice, but not in D2 mice. Even among isogenic B6 mice, the response is variable for reasons that presumably trace back to subtle developmental, environmental, and technical factors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.1002/j.1538-9235.2004.tb01891.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 210

Metadata

Authors
Schaeffel, F., Burkhardt, E., Howland, H. C., & Williams, R. W.
Venue
Optometry and Vision Science
Publisher
Lippincott Williams & Wilkins
Published
2004-02-01
Volume
81
Issue
2
Pages
99-110
ISSN
1040-5488 (ISSN-L)
OpenAlex
W2071162166
Cited by
210
References
1
FWCI
4.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of Refractive State and Deprivation Myopia in Two Strains of Mice. https://app.cochat.ai/papers/10.1002/j.1538-9235.2004.tb01891.x
The paper
Schaeffel, F., Burkhardt, E., Howland, H. C., & Williams, R. W. (2004). Measurement of Refractive State and Deprivation Myopia in Two Strains of Mice. Optometry and Vision Science. https://doi.org/10.1002/j.1538-9235.2004.tb01891.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.