Measurement of Refractive State and Deprivation Myopia in Two Strains of Mice
The DOI matches its OpenAlex record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
PURPOSE: The mouse eye has a bright retinal image (f/number <1) but low optical quality (visual acuity about 0.5 cpd) that may render emmetropization unnecessary. However, this species is potentially a powerful model to study eye growth and myopia because its genome can be readily manipulated and has been completely sequenced. We have investigated how precisely eyes of mice can be refracted and tested whether deprivation myopia can be induced by frosted diffusers. METHODS: An automated eccentric infrared photorefractor was adapted to refract eyes of two mouse strains--C57BL/6 (B6) and DBA/2 (D2)--during Tropicamide cycloplegia without anesthesia. Axial lengths were measured in highly magnified video images of freshly excised eyes. Plastic hemispherical diffusers were applied between postnatal days and 29 and left attached for 7 or 14 days. RESULTS: (1) Trial lenses ranging from +10 to -10 D produced high correlations between the brightness slope in the pupil and applied lens power (r = 0.81 and r = 0.87), demonstrating reliable refraction. Five repeated measures in 12 eyes showed an average standard deviation of 3.0 D, equivalent to an axial length change <10 microm (derived from schematic eye modeling). (2) Deprivation produced a significant shift toward myopia, relative to untreated eyes, but only after 14 days and only in B6 mice (p = 0.02 with or p = 0.00038 without one outlier; N = 9). In contrast, DBA/2J were unaffected by occlusion, perhaps due to mutations that target eye, lens, or anterior segment. (3) Both eyes of untreated animals often had axial lengths that differed markedly. Surprisingly, we detected no significant correlation between refractive error and axial length after treatment. CONCLUSIONS: The infrared refraction technique is sufficiently sensitive to resolve equivalent changes in axial length of only +/- 10 microm in alert mice. Prolonged occlusion produces a significant myopic shift in B6 mice, but not in D2 mice. Even among isogenic B6 mice, the response is variable for reasons that presumably trace back to subtle developmental, environmental, and technical factors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Initial sequencing and comparative analysis of the mouse genome
Mouse Genome Sequencing Consortium (2002) · Nature · doi:10.1038/nature01262 · Cited by 7,187
Essential iris atrophy, pigment dispersion, and glaucoma in DBA/2J mice.
John, S. W. M., Smith, R. S., Savinova, O. V., Hawes, N. L., Chang, B., Turnbull, D., Davisson, M. T., Roderick, T. H., & Heckenlively, J. R. (1998) · PubMed · Cited by 603
Behavioral assessment of visual acuity in mice and rats
Prusky, G. T., West, P. W. R., & Douglas, R. M. (2000) · Vision Research · doi:10.1016/s0042-6989(00)00081-x · Cited by 589
Retinal dopamine and form-deprivation myopia.
Stone, R. A., Lin, T., Laties, A. M., & Iuvone, P. M. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.2.704 · Cited by 453
Receptive fields of single cells and topography in mouse visual cortex
Dräger, U. C. (1975) · Journal of Comparative Neurology · doi:10.1002/cne.901600302 · Cited by 415
A schematic eye for the mouse, and comparisons with the rat
Remtulla, S., & Hallett, P. E. (1985) · Vision Research · doi:10.1016/0042-6989(85)90076-8 · Cited by 386
Glickstein, M., & Millodot, M. (1970) · Science · doi:10.1126/science.168.3931.605 · Cited by 326
Interacting loci cause severe iris atrophy and glaucoma in DBA/2J mice
Chang, B., Smith, R. S., Hawes, N. L., Anderson, M. G., Zabaleta, A., Savinova, O., Roderick, T. H., Heckenlively, J. R., Davisson, M. T., & John, S. W. M. (1999) · Nature Genetics · doi:10.1038/7741 · Cited by 294
Properties of the feedback loops controlling eye growth and refractive state in the chicken
Schaeffel, F., & Howland, H. C. (1991) · Vision Research · doi:10.1016/0042-6989(91)90011-s · Cited by 244
Self-citationLight- and focus-dependent expression of the transcription factor ZENK in the chick retina
Fischer, A. J., McGuire, J. J., Schaeffel, F., & Stell, W. K. (1999) · Nature Neuroscience · doi:10.1038/11167 · Cited by 227
Self-citation
Cited by
Homeostasis of Eye Growth and the Question of Myopia
Wallman, J., & Winawer, J. (2004) · Neuron · doi:10.1016/j.neuron.2004.08.008 · Cited by 1,060
Scleral hypoxia is a target for myopia control
Wu, H., Chen, W., Zhao, F., Zhou, Q., Reinach, P. S., Deng, L., Ma, L., Luo, S., Srinivasalu, N., Pan, M., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1721443115 · Cited by 500
IMI – Report on Experimental Models of Emmetropization and Myopia
Troilo, D., Smith, E. L., Nickla, D. L., Ashby, R., Tkatchenko, A. V., Ostrin, L. A., Gawne, T. J., Pardue, M. T., Summers, J. A., Kee, C.-S., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25967 · Cited by 487
“7–11 D(57)) and between studies, with estimates ranging to over 20 D.(48) Perhaps due to refractive error measurements starting later in development, mice do not seem to exhibit an obvious reduction in the intersubject variability in refractive errors from 20 to 100 days of age.”
BackgroundA paraxial schematic eye model for the growing C57BL/6 mouse
Schmucker, C., & Schaeffel, F. (2004) · Vision Research · doi:10.1016/j.visres.2004.03.011 · Cited by 255
Self-citationChanges in Choroidal Thickness and Choroidal Blood Perfusion in Guinea Pig Myopia
Zhang, S., Zhang, G., Zhou, X., Xu, R., Wang, S., Guan, Z., Lu, J., Srinivasalu, N., Shen, M., Jin, Z., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-26397 · Cited by 221
Form-deprivation myopia in the guinea pig (Cavia porcellus)
Howlett, M. H. C., & McFadden, S. A. (2006) · Vision Research · doi:10.1016/j.visres.2005.06.036 · Cited by 210
Animal models in myopia research
Schaeffel, F., & Feldkaemper, M. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12312 · Cited by 188
Self-citationZhao, F., Zhang, D., Zhou, Q., Zhao, F., He, M., Yang, Z., Su, Y., Zhai, Y., Yan, J., Zhang, G., et al. (2020) · EBioMedicine · doi:10.1016/j.ebiom.2020.102878 · Cited by 172
Metadata
- Authors
- Schaeffel, F., Burkhardt, E., Howland, H. C., & Williams, R. W.
- Venue
- Optometry and Vision Science
- Publisher
- Lippincott Williams & Wilkins
- Published
- 2004-02-01
- Volume
- 81
- Issue
- 2
- Pages
- 99-110
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2071162166
- Cited by
- 210
- References
- 30
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.