CoChat

Chemistry of arsenic removal during coagulation and Fe–Mn oxidation

Edwards, Marc · 1994 · Journal AWWA
Cited by 351

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

Recent studies have indicated that arsenic in drinking water is as hazardous as radon in homes and secondhand tobacco smoke. Arsenic removal during coagulation or Fe–Mn oxidation is examined to aid utilities that desire to improve arsenic removal. Fundamental mechanisms of arsenic removal are discussed, optimization strategies are forwarded, and some new insights are provided to guide future research. Specifically, As(III) removals by coagulation are primarily controlled by coagulant dose and relatively unaffected by solution pH, whereas the converse is true for As(V). When compared on the basis of moles iron or aluminum hydroxide solid formed during coagulation, iron and aluminum coagulants are of demonstrably equal effectiveness in removing As(V) at pH <7.5. However, iron‐based coagulants are advantageous if soluble metal residuals are problematic, if pH is >7.5, or if the raw water contains As(III). Arsenic removal during Fe–Mn oxidation is controlled by the quantity of iron removed [Fe(OH)3 formed] and is relatively independent of the quantity of manganese removed (MnOOH formed).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/j.1551-8833.1994.tb06247.x

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 351

Metadata

Authors
Edwards, M.
Venue
Journal AWWA
Publisher
Wiley
Published
1994-09
Volume
86
Issue
9
Pages
64-78
ISSN
  • 0003-150X (ISSN-L)
  • 1551-8833
OpenAlex
W1520748060
Cited by
351
References
32
FWCI
5.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.