CoChat

The effects of different steam‐sterilization programs on material properties of poly(L‐lactide)

Rozema, F. R., Bos, R. R. M., Boering, G., van Asten, J. A. A. M., Nijenhuis, A. J., Pennings, A. J. · 1991 · Journal of Applied Biomaterials

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

As‐polymerized poly(L‐lactide) test rods were sterilized by seven different specially designed computer‐operated autoclaving programs. As a control, common hospital sterilization was performed. In all cases, the molecular weight decreased after sterilization. A short time high‐temperature sterilization lead to less molecular weight decrease than a low sterilization temperature cycle with a longer sterilization time. Regular hospital sterilization significantly reduced the elongation at break and also resulted in a decrease of 35% in tensile strength. The program causing minimal damage to the material properties was studied in detail. This program, with a steriliztioan period of 60 s and 129°C, was effective for PLLA steriliztation and also looks very promising for sterilization of other thermo‐ and moisture‐labile polymers.

Overview

Integrity signals

Registry

Crossref · 10.1002/jab.770020104

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 20 references

Research works printed but not linked: 5

  1. Heponen V.‐P.;Pohjonen T.;Vainionpää S.;Törmälä P.The effect of gamma‐radiation on mechanical properties of biodegradable poly‐l‐lactide fibers. Transactions of the Third World Biomaterials Congress;281: Kyoto Japan;1988April 21–25.
  2. Lynch D. W., 1981, Carcinogenic and toxicologic effects of safety and health series no. 46, 249
  3. Wallhäuser K. H., 1978, Keimidentifizierung‐Betriebshygiene
  4. Whitby J. L.Microbiological aspects of radiation dose setting. Proceedings on the third gamma processing seminar; Technical paper GPS 343 Atomic Energy of Canada Limited Ottawa;1983June 6–9.
  5. Davis K. W.A statistical point of view of gamma irradiation sterilization dose setting in North America. Proceedings on the third gamma processing seminar; Technical paper GPS 342 Atomic Energy of Canada Limited Ottawa;1983June 6–9.

Cited by

See all 68

Metadata

Authors
Rozema, F. R., Bos, R. R. M., Boering, G., van Asten, J. A. A. M., Nijenhuis, A. J., & Pennings, A. J.
Affiliations
  • University Medical Center Groningen (NL)
  • University of Groningen (NL)
Corresponding author
Rozema, F. R.
Venue
Journal of Applied Biomaterials
Publisher
Wiley
Published
1991-03
Volume
2
Issue
1
Pages
23-28
ISSN
  • 1045-4861 (ISSN-L)
  • 1549-9316
OpenAlex
W1971775104
Cited by
57
References
20
Citations by year
2024: 1 · 2023: 2 · 2022: 3 · 2021: 6 · 2020: 3 · 2019: 6 · 2018: 3 · 2017: 2 · 2016: 5 · 2015: 1 · 2014: 2 · 2013: 3 · 2012: 2
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Applied Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion)
Topics
  • Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
Keywords
poly(L-lactic acid), autoclaving, sterilization temperature, sterilization time, molecular weight degradation, tensile strength, elongation at break, polymer properties
MeSH terms
Humans, Materials Testing, Molecular Weight, Polyesters, Sterilization, Tensile Strength

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effects of different steam‐sterilization programs on material properties of poly(L‐lactide). https://app.cochat.ai/papers/10.1002/jab.770020104
The paper
Rozema, F. R., Bos, R. R. M., Boering, G., van Asten, J. A. A. M., Nijenhuis, A. J., & Pennings, A. J. (1991). The effects of different steam‐sterilization programs on material properties of poly(L‐lactide). Journal of Applied Biomaterials. https://doi.org/10.1002/jab.770020104

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.