CoChat

Energy dispersive X‐ray analysis of titanium dioxide nanoparticle distribution after intravenous and subcutaneous injection in mice

Patri, Anil, Umbreit, Thomas, Zheng, J., Nagashima, K., Goering, Peter, Francke‐Carroll, Sabine, Gordon, Edward, Weaver, James, Miller, Terry, Sadrieh, Nakissa, McNeil, Scott, Stratmeyer, Mel · 2009 · Journal of Applied Toxicology
Cited by 80

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

In an effort to understand the disposition and toxicokinetics of nanoscale materials, we used EDS (energy dispersive X‐ray spectroscopy) to detect and map the distribution of titanium dioxide (TiO 2) in tissue sections from mice following either subcutaneous (s.c.) or intravenous (i.v.) injection. TiO 2 nanoparticles were administered at a dose of 560 mg/kg (i.v.) or 5600 mg/kg (s.c.) to Balb/c female mice on two consecutive days. Tissues (liver, kidney, lung, heart, spleen, and brain) were examined by light microscopy, TEM (transmission electron microscopy), SEM (scanning electron microscopy), and EDS following necropsy one day after treatment. Particle agglomerates were detected by light microsopy in all tissues examined, EDS microanalysis was used to confirm that these tissues contained elemental titanium and oxygen. The TEM micrographs and EDS spectra of the aggregates were compared with in vitro measurements of TiO 2 nanoparticle injection solution (i.e., in water). The nanoparticles were also characterized using dynamic light scattering in water, 10 mM NaCl, and phosphate buffered saline (PBS). In low ionic strength solvents (water and 10 mM NaCl), the TiO 2 particles had average hydrodynamic diameters ranging from 114–122 nm. In PBS, however, the average diameter increases to 1–2 μm, likely due to aggregation analogous to that observed in tissue by TEM and EDS. This investigation demonstrates the suitability of energy dispersive X‐ray spectroscopy (EDS) for detection of nanoparticle aggregates in tissues and shows that disposition of TiO 2 nanoparticles depends on the route of administration (i.v. or s.c.). Published in 2009 by John Wiley and Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jat.1454

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 80

Metadata

Authors
Patri, A., Umbreit, T., Zheng, J., Nagashima, K., Goering, P., Francke‐Carroll, S., Gordon, E., Weaver, J., Miller, T., Sadrieh, N., McNeil, S., & Stratmeyer, M.
Venue
Journal of Applied Toxicology
Publisher
Wiley
Published
2009-07-22
Volume
29
Issue
8
Pages
662-672
ISSN
  • 0260-437X (ISSN-L)
  • 1099-1263
OpenAlex
W1967822639
Cited by
80
References
1
FWCI
2.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Energy dispersive X‐ray analysis of titanium dioxide nanoparticle distribution after intravenous and subcutaneous injection in mice. https://app.cochat.ai/papers/10.1002/jat.1454
The paper
Patri, A., Umbreit, T., Zheng, J., Nagashima, K., Goering, P., Francke‐Carroll, S., Gordon, E., Weaver, J., Miller, T., Sadrieh, N., McNeil, S., & Stratmeyer, M. (2009). Energy dispersive X‐ray analysis of titanium dioxide nanoparticle distribution after intravenous and subcutaneous injection in mice. Journal of Applied Toxicology. https://doi.org/10.1002/jat.1454

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.