Bond‐selective imaging of deep tissue through the optical window between 1600 and 1850 nm
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We report the employment of an optical window between 1600 nm and 1850 nm for bond‐selective deep tissue imaging through harmonic vibrational excitation and acoustic detection of resultant pressure waves. In this window where a local minimum of water absorption resides, we found a 5 times enhancement of photoacoustic signal by first overtone excitation of the methylene group CH 2 at 1730 nm, compared to the second overtone excitation at 1210 nm. The enhancement allows 3D mapping of intramuscular fat with improved contrast and of lipid deposition inside an atherosclerotic artery wall in the presence of blood. Moreover, lipid and protein are differentiated based on the first overtone absorption profiles of CH 2 and methyl group CH 3 in this window. (© 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Imaging of atherosclerotic cardiovascular disease
Sanz, J., & Fayad, Z. A. (2008) · Nature · doi:10.1038/nature06803 · Cited by 558
Amirbekian, V., Lipinski, M. J., Briley-Saebo, K. C., Amirbekian, S., Aguinaldo, J. G. S., Weinreb, D. B., Vucic, E., Frias, J. C., Hyafil, F., Mani, V., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606281104 · Cited by 356
Cited by
Vibrational spectroscopic imaging of living systems: An emerging platform for biology and medicine
Cheng, J.-X., & Xie, X. S. (2015) · Science · doi:10.1126/science.aaa8870 · Cited by 874
Self-citationWilson, R. H., Nadeau, K. P., Jaworski, F. B., Tromberg, B. J., & Durkin, A. J. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.3.030901 · Cited by 415
Transmission in near‐infrared optical windows for deep brain imaging
Shi, L., Sordillo, L. A., Rodríguez‐Contreras, A., & Alfano, R. (2016) · Journal of Biophotonics · doi:10.1002/jbio.201500192 · Cited by 346
Golovynskyi, S., Golovynska, I., Stepanova, L. I., Datsenko, O. I., Liu, L., Qu, J., & Ohulchanskyy, T. Y. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201800141 · Cited by 209
Diffuse optical characterization of collagen absorption from 500 to 1700 nm
Sekar, S. K. V., Bargigia, I., Mora, A. D., Taroni, P., Ruggeri, A., Tosi, A., Pifferi, A., & Farina, A. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.1.015006 · Cited by 168
“was reported using photoacoustics at SWIR wavelengths as compared to the near-infrared region.(15,16) For collagen, the high absorption in the SWIR region(9) can be exploited to investigate its dynamics of growth in studies related to tissue culture or engineering.”
Metadata
- Authors
- Wang, P., Wang, H., Sturek, M., & Cheng, J.
- Venue
- Journal of Biophotonics
- Publisher
- Wiley
- Published
- 2011-11-28
- Volume
- 5
- Issue
- 1
- Pages
- 25-32
- ISSN
- 1864-063X (ISSN-L)
- 1864-0648
- OpenAlex
- W1968873280
- Cited by
- 90
- References
- 3
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.