The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Surface plasmon resonance based biosensor technique: A review
Abstract
Optical Surface plasmon resonance (SPR) biosensors represent the most advanced and developed optical label‐free biosensor technology. Optical SPR biosensors are a powerful detection and analysis tool that has vast applications in environmental protection, biotechnology, medical diagnostics, drug screening, food safety and security. This article reviews the recent development of SPR biosensor techniques, including bulk SPR and localized SPR (LSPR) biosensors, for detecting interactions between an analyte of interest in solution and a biomolecular recognition. The concepts of bulk and localized SPs and the working principles of both sensing techniques are introduced. Major sensing advances on biorecognition elements, measurement formats, and sensing platforms are presented. Finally, the discussions on both biosensor techniques as well as comparison of both SPR sensing techniques are made. (© 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Haes, A. J., & Van Duyne, R. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020393x · Cited by 2,057
Cited by
Cytokines: From Clinical Significance to Quantification
Liu, C., Chu, D., Kalantar‐Zadeh, K., George, J., Young, H. A., & Liu, G. (2021) · Advanced Science · doi:10.1002/advs.202004433 · Cited by 940
Stress Biomarkers in Biological Fluids and Their Point-of-Use Detection
Steckl, A. J., & Ray, P. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00726 · Cited by 319
Kurhade, R. R., Shaikh, M. S., Nagulwar, V., & Kale, M. A. (2025) · International Journal of Polymeric Materials and Polymeric Biomaterials · doi:10.1080/00914037.2024.2391973 · Cited by 55
Action mechanism of a novel agrichemical quinofumelin against Fusarium graminearum
Xiu, Q., Yin, X., Chen, Y., Zhang, Z., Mao, Y., Wang, T., Zhang, J., Zhou, M., & Duan, Y. (2025) · eLife · doi:10.7554/elife.105892.3 · Cited by 11
Action mechanism of a novel agrichemical quinofumelin against Fusarium graminearum
Xiu, Q., Yin, X., Chen, Y., Zhang, Z., Mao, Y., Wang, T., Zhang, J., Zhou, M., & Duan, Y. (2025) · eLife · doi:10.7554/elife.105892 · Cited by 1
Metadata
- Authors
- Guo, X.
- Venue
- Journal of Biophotonics
- Publisher
- Wiley
- Published
- 2012-03-30
- Volume
- 5
- Issue
- 7
- Pages
- 483-501
- ISSN
- 1864-063X (ISSN-L)
- 1864-0648
- OpenAlex
- W1987533236
- Cited by
- 436
- References
- 1
- FWCI
- 14.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface plasmon resonance based biosensor technique: A review. https://app.cochat.ai/papers/10.1002/jbio.201200015
- The paper
- Guo, X. (2012). Surface plasmon resonance based biosensor technique: A review. Journal of Biophotonics. https://doi.org/10.1002/jbio.201200015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.