The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In vivo evaluation of a dexamethasone/PLGA microsphere system designed to suppress the inflammatory tissue response to implantable medical devices
Abstract
The purpose of this research effort was to evaluate in vivo a newly developed dexamethasone/PLGA microsphere system designed to suppress the inflammatory tissue response to an implanted device, in this case a biosensor. The microspheres were prepared using an oil/water (O/W) emulsion technique. The microsphere system was composed of drug‐loaded microspheres (including newly formulated and predegraded microspheres) and free dexamethasone. The combination of the drug and drug‐loaded microspheres provided burst release of dexamethasone followed by continuous release from days 2–14. Continuous release to at least 30 days was achieved by mixing predegraded and newly formulated microspheres. The ability of our mixed microsphere system to control tissue reactions to an implant then was tested in vivo using cotton thread sutures to induce inflammation subcutaneously in Sprague−Dawley rats. Two different in vivo studies were performed, the first to find the dosage level of dexamethasone that effectively would suppress the acute inflammatory reaction and the second to show how effective the dexamethasone delivered by PLGA microspheres was in suppressing chronic inflammatory response to an implant. The first in vivo study showed that 0.1 to 0.8 mg of dexamethasone at the site minimized the acute inflammatory reaction. The second in vivo study showed that our mixed microsphere system suppressed the inflammatory response to an implanted suture for at least 1 month. This study has proven the viability of microsphere delivery of an anti‐inflammatory to control the inflammatory reaction at an implant site. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 61: 180–187, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hickey, T., Kreutzer, D., Burgess, D. J., & Moussy, F. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00291-5 · Cited by 268
Self-citation
Cited by
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response
Morais, J. M., Papadimitrakopoulos, F., & Burgess, D. J. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9175-3 · Cited by 560
Self-citationDrug/device combinations for local drug therapies and infection prophylaxis
Wu, P., & Grainger, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.031 · Cited by 491
Onuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200610 · Cited by 418
Self-citation
Metadata
- Authors
- Hickey, T., Kreutzer, D., Burgess, D. J., & Moussy, F.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2002-04-18
- Volume
- 61
- Issue
- 2
- Pages
- 180-187
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2053799712
- Cited by
- 187
- References
- 1
- FWCI
- 6.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.