The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fabrication of porous biodegradable polymer scaffolds using a solvent merging/particulate leaching method
Abstract
This study developed a solvent merging/par‐ ticulate leaching method for preparing three‐dimensional porous scaffolds. Poly(L‐lactic‐co‐glycolic acid) (PLGA) and sodium chloride particles were dry‐mixed and cast into a special mold, through which a liquid could pass due to a pressure difference. An organic solvent was then poured into the mold to dissolve and merge the PLGA particles under negative pressure. A nonsolvent was conducted into the PLGA/salt composite to solidify and precipitate the merged PLGA matrix. Finally, a large amount of water was passed through the mold to leach out the salt particles so as to create a porous structure. The results revealed that a highly porous three‐dimensional scaffold (>85 vol %) with a well interconnected porous structure could be achieved by this process. Porosity and the pore size of the scaffold were controlled using the ratio and the particle size of the added salt particles. A larger‐volume scaffold was produced using a larger mold. This work provides a continuous and simple procedure for fabricating a bulk three‐dimensional porous scaffold for tissue engineering. © 2001 Wiley Periodicals, Inc. J Biomed Mater Res 59: 676–681, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Cited by
Polymeric Scaffolds for Bone Tissue Engineering
Liu, X., & Ma, P. X. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000017544.36001.8e · Cited by 1,345
Three-dimensional aqueous-derived biomaterial scaffolds from silk fibroin
Kim, U.-J., Park, J., Joo Kim, H., Wada, M., & Kaplan, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.044 · Cited by 979
Fechler, N., Fellinger, T., & Antonietti, M. (2013) · Advanced Materials · doi:10.1002/adma.201203422 · Cited by 510
Poly (lactic acid)-based biomaterials for orthopaedic regenerative engineering
Narayanan, G., Vernekar, V. N., Kuyinu, E. L., & Laurencin, C. T. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.04.015 · Cited by 484
Karande, T. S., Ong, J. L., & Agrawal, C. M. (2004) · Annals of Biomedical Engineering · doi:10.1007/s10439-004-7825-2 · Cited by 457
Metadata
- Authors
- Liao, C., Chen, C., Chen, J., Chiang, S., Lin, Y., & Chang, K.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2001-12-12
- Volume
- 59
- Issue
- 4
- Pages
- 676-681
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2143035084
- Cited by
- 283
- References
- 2
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fabrication of porous biodegradable polymer scaffolds using a solvent merging/particulate leaching method. https://app.cochat.ai/papers/10.1002/jbm.10030
- The paper
- Liao, C., Chen, C., Chen, J., Chiang, S., Lin, Y., & Chang, K. (2002). Fabrication of porous biodegradable polymer scaffolds using a solvent merging/particulate leaching method. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.10030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.