The DOI matches its Crossref record.
In vitro dissolution of melt‐derived 45S5 and sol‐gel derived 58S bioactive glasses
Abstract
Effects of powder type, particle size (5–20 μm; 90–300 μm; 90–710 μm), and type of dissolution medium on the dissolution behavior of bioactive glasses were investigated in vitro using melt‐derived 45S5 and sol‐gel derived 58S bioactive glass powders. Dissolution studies were performed in simulated body fluid and in α‐MEM based cell culture medium at 37°C under dynamic conditions (1 Hz) for periods of 30 min, 1, 2, 4, 8, 17, and 22 h. The concentrations of elements dissolved from the glasses were evaluated using inductively coupled plasma analysis. The reacted powders were analyzed for bioactivity using Fourier transform infrared spectrometry to observe the formation of a calcium phosphate layer on the surface. The non‐porous surfaces of melt‐derived 45S5 glass powders exhibited lower dissolution rates and rate of surface layer formation than 58S gel‐glass powders. The rates of dissolution for both types of powders were lower in culture medium, compared to simulated body fluid , and increased as the particle size decreased. Thus, particle size range, glass type, and powder volume fraction can be used as a means to control the release rate of active ions that stimulate the gene expression and cellular response for tissue proliferation and repair. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 61: 301–311, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A unified in vitro evaluation for apatite-forming ability of bioactive glasses and their variants
Maçon, A. L. B., Kim, T. B., Valliant, E. M., Goetschius, K., Brow, R. K., Day, D. E., Hoppe, A., Boccaccini, A. R., Kim, I. Y., Ohtsuki, C., et al. (2015) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-015-5403-9 · Cited by 489
Self-citationBioactive sol‐gel foams for tissue repair
Sepulveda, P., Jones, J. R., & Hench, L. L. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1250 · Cited by 441
Self-citationCharacterization of melt‐derived 45S5 and sol‐gel–derived 58S bioactive glasses
Sepulveda, P., Jones, J. R., & Hench, L. L. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10026 · Cited by 434
Self-citationFernandes, H. R., Gaddam, A., Rebelo, A., Brazete, D., Stan, G. E., & Ferreira, J. M. F. (2018) · Materials · doi:10.3390/ma11122530 · Cited by 397
Metadata
- Authors
- Sepulveda, P., Jones, J. R., & Hench, L. L.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2002-04-26
- Volume
- 61
- Issue
- 2
- Pages
- 301-311
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2012664920
- Cited by
- 470
- References
- 0
- FWCI
- 8.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vitro dissolution of melt‐derived 45S5 and sol‐gel derived 58S bioactive glasses. https://app.cochat.ai/papers/10.1002/jbm.10207
- The paper
- Sepulveda, P., Jones, J. R., & Hench, L. L. (2002). In vitro dissolution of melt‐derived 45S5 and sol‐gel derived 58S bioactive glasses. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.10207
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.