Thin film rheology and lubricity of hyaluronic acid solutions at a normal physiological concentration
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Using a surface forces apparatus to measure forces, and optical (multiple beam) interferometry to measure surface shapes and separations (to ±1 Å), the normal, viscous, and shear (lubrication) forces between smooth mica surfaces in aqueous hyaluronic acid (HA) solutions were measured. The experimental conditions of loading pressures, pH, and HA concentration were set to closely correspond to physiological human knee‐joint conditions. From the force and optical (refractive index) measurements, it was concluded that, like other negatively charged polyelectrolytes, HA does not naturally adsorb on the mica surface which is hydrophilic and weakly negatively charged at physiological conditions: the polymer solution exhibits the bulk viscosity (22.5 ± 1.5 cP) for films thicker than about 0.4 μm of the polymer, whereas for thinner films, the viscosity decreases monotonically toward the value of the pure electrolyte solution (1 cP) as HA is extruded from between the surfaces. This is indicative of a repulsive “depletion” interaction of HA with each mica surface and to a weakly attractive polymer‐mediated force between the two surfaces. Thus, free HA in synovial fluid is not expected to act as a good “boundary lubricant.” Relaxation measurements on approaching and receding surfaces in HA solutions were also performed, and it is shown that the presence of HA in the bulk solution can improve “hydrodynamic” modes of lubrication, for example, by assuaging the compression stroke. The study includes information that is beneficial to researchers working with biomaterials viscosupplementation devices. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 61: 514–523, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scaling Concepts in Polymer Physics
de Gennes, P. G., & Witten, T. A. (1980) · Physics Today · doi:10.1063/1.2914118 · Cited by 9,348
Israelachvili, J. N., & Adams, G. E. (1978) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19787400975 · Cited by 1,812
Self-citationReduction of frictional forces between solid surfaces bearing polymer brushes
Klein, J., Kumacheva, E., Mahalu, D., Perahia, D., & Fetters, L. J. (1994) · Nature · doi:10.1038/370634a0 · Cited by 615
Shear and Frictional Interactions between Adsorbed Polymer Layers in a Good Solvent
Raviv, U., Tadmor, R., & Klein, J. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp0041860 · Cited by 103
Self-citation
Research works printed but not linked: 41
- Sokoloff L, 1978, The joint and synovial fluid
- McCutchen CW, 1978, The joints and synovial fluid, 454
- 10.1093/oxfordjournals.rheumatology.a031463 · DOI
- McCutchen CW, 1978, The joints and synovial fluid, 457
- 10.1243/0954411981533791 · DOI · Paper page
- 10.1097/00002281-200009000-00022 · DOI
- 10.1242/jcs.106.1.365 · DOI · Paper page
- Jay GD, 2000, Lubricin is a product of megakaryocyte stimulating factor gene expression by human synovial fibroblasts, J Rheumatol, 27, 594
- 10.1002/(SICI)1097-4636(19980605)40:3<414::AID-JBM11>3.0.CO;2-J · DOI · Paper page
- McKibbin B, 1973, Adult cartilage
- Stockwell RA, 1979, Biology of cartilage cells
- Saxena RK, 1998, Interplay of matrices in cartilage synovial fluid combine under moderate and high loadings, Indian J Med Res, 107, 123
- McCutchen CW, 1978, The joints and synovial fluid, 437
- Balazs EA, 1974, Disorders of the knee, 63
- 10.1007/978-1-4615-5801-9 · DOI
- 10.1021/ma00077a036 · DOI · Paper page
- Van Krevelen DW, 2000, Properties of polymers
- 10.1557/JMR.1990.2223 · DOI · Paper page
- 10.1016/0021-9797(73)90218-X · DOI · Paper page
- 10.1007/BF01433225 · DOI · Paper page
- 10.1021/ma9519122 · DOI · Paper page
- 10.1016/0021-9797(86)90376-0 · DOI · Paper page
- 10.1295/polymj.30.345 · doi:10.1295/polymj.30.345
- 10.1021/ma00204a033 · DOI · Paper page
- 10.1021/la960452i · DOI · Paper page
- 10.1021/la960412e · DOI
- Israelachvili JN, 1991, Intermolecular and surface forces
- 10.1063/1.1699109 · doi:10.1063/1.1699109
- 10.1021/ma011893y · DOI
- Klein J, 1988, Molecular conformation and dynamics of macromolecules in condensed systems
- 10.1016/0043-1648(90)90072-I · DOI · Paper page
- 10.1243/0954411001535264 · DOI · Paper page
- 10.1021/ma971431d · doi:10.1021/ma971431d
- 10.1002/pol.1979.180170615 · doi:10.1002/pol.1979.180170615
- 10.1021/ma50007a007 · DOI · Paper page
- 10.1063/1.1740347 · DOI · Paper page
- 10.1002/pol.1958.1203312618 · DOI · Paper page
- 10.1098/rspa.1971.0141 · DOI · Paper page
- 10.1515/crll.1882.92.156 · DOI · Paper page
- 10.1021/ma60075a033 · DOI · Paper page
- SchreiterC.Diploma thesis. Untersuchung weicher adsobierter Polymerfilme auf Festkörper mittels Kraft‐Apparatur. Technische Universität München March 2000.
Cited by
Klein, J. (2013) · Friction · doi:10.1007/s40544-013-0001-7 · Cited by 567
Boundary lubrication of articular cartilage: Role of synovial fluid constituents
Schmidt, T. A., Gastelum, N. S., Nguyen, Q. T., Schumacher, B. L., & Sah, R. L. (2007) · Arthritis & Rheumatism · doi:10.1002/art.22446 · Cited by 554
Lubrication of Articular Cartilage
Jahn, S., Seror, J., & Klein, J. (2016) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-081514-123305 · Cited by 406
Zhang, S., Huang, J., Cheng, Y., Yang, H., Chen, Z., & Lai, Y. (2017) · Small · doi:10.1002/smll.201701867 · Cited by 328
Hyaluronic Acid and Dextran-Based Semi-IPN Hydrogels as Biomaterials for Bioprinting
Pescosolido, L., Schuurman, W., Malda, J., Matricardi, P., Alhaique, F., Coviello, T., van Weeren, P. R., Dhert, W. J. A., Hennink, W. E., & Vermonden, T. (2011) · Biomacromolecules · doi:10.1021/bm200178w · Cited by 280
Metadata
- Authors
- Tadmor, R., Chen, N., & Israelachvili, J. N.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2002-05-30
- Volume
- 61
- Issue
- 4
- Pages
- 514-523
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1982132247
- Cited by
- 108
- References
- 4
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.