The DOI matches its Crossref record.
A tissue sealant based on reactive multifunctional polyethylene glycol
Abstract
A rapidly gelling synthetic tissue sealant was developed from tetra‐succinimidyl and tetra‐thiol‐derivatized polyethylene glycol (PEG). The two reagents were dissolved in aqueous buffers at 20% (w/v) solids and sprayed on the tissue site, with the use of a sprayer/mixer device. Good adhesion to collagen membranes, PTFE grafts, and carotid artery was observed in vitro. In a burst test on collagen membranes with a 2‐mm orifice defect, the gel sustained fluid pressures of 125 ± 36 mm Hg (n = 18), fivefold greater than capillary blood pressure and one‐half that observed in hypertension. On 0.4‐mm‐diameter puncture defects in PTFE grafts, pressures of 390–490 mm Hg were sustained, and on 0.6–0.9‐mm puncture defects in carotid arteries, pressures of 490 to 840 mm Hg were sustained. In vitro data corresponded to results in vivo, where bleeding in rabbit arteries was stopped immediately in five out of six trials. A significant reduction in time to hemostasis and blood loss, compared to controls, was observed. Carotid artery and subcutaneous implant data in rabbits showed that the formula was compatible with biological tissue. Rapid gelling and effective sealing were dependent on the presence of active succinimidyl ester and thiol groups on PEG. HPLC and chemical substitution methods were useful in predicting whether batches of derivatized PEG would perform satisfactorily. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 58: 545–555, 2001
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tough adhesives for diverse wet surfaces
Li, J., Celiz, A. D., Yang, J., Yang, Q., Wamala, I., Whyte, W., Seo, B. R., Vasilyev, N. V., Vlassak, J. J., Suo, Z., et al. (2017) · Science · doi:10.1126/science.aah6362 · Cited by 1,598
Nam, S., & Mooney, D. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00798 · Cited by 764
Biomaterials and Advanced Technologies for Hemostatic Management of Bleeding
Hickman, D. A., Pawlowski, C. L., Sekhon, U. D. S., Marks, J., & Gupta, A. S. (2018) · Advanced Materials · doi:10.1002/adma.201700859 · Cited by 583
Collagen gel systems for sustained delivery and tissue engineering
Wallace, D. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.004 · Cited by 488
Self-citationThe chemistry of tissue adhesive materials
Bouten, P. J. M., Zonjee, M., Bender, J., Yauw, S. T. K., van Goor, H., van Hest, J. C. M., & Hoogenboom, R. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2014.02.001 · Cited by 448
Metadata
- Authors
- Wallace, D. G., Cruise, G. M., Rhee, W. M., Schroeder, J. A., Prior, J. J., Ju, J., Maroney, M., Duronio, J., Ngo, M. H., Estridge, T., & Coker, G. C.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2001-01
- Volume
- 58
- Issue
- 5
- Pages
- 545-555
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2003805337
- Cited by
- 205
- References
- 0
- FWCI
- 1.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A tissue sealant based on reactive multifunctional polyethylene glycol. https://app.cochat.ai/papers/10.1002/jbm.1053
- The paper
- Wallace, D. G., Cruise, G. M., Rhee, W. M., Schroeder, J. A., Prior, J. J., Ju, J., Maroney, M., Duronio, J., Ngo, M. H., Estridge, T., & Coker, G. C. (2001). A tissue sealant based on reactive multifunctional polyethylene glycol. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.1053
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.