The DOI matches its Crossref record.
Reactions of the articular capsule to wear products of artificial joint prostheses
Abstract
Examination of a great number of tissue samples taken from the newly formed capsules surrounding artificial joints reveals small particles of prosthetic material. Abraded from the joint by wear and tear, these particles of plastic, metal, and acrylic cement initiate a foreign‐body reaction and result in the formation of granulation tissue, including macrophages and foreign‐body giant cells. Typical features of tissue reactions exist for each of the materials from which prostheses are made. The consequent formation of scar tissue produces a thickening of the capsule, which, in turn, may cause a reduction in the mobility of the joint. In small amounts, the foreign‐body particles are eliminated via the perivascular lymph spaces. Where this transport system is insufficient to handle the volume, however, the foreign‐body response may extend to the whole environment surrounding the joint. In such cases, there may be loosening of the cemented prosthetic parts because of deterioration of contiguous bone anchors by the tissue membrane lining the bone cement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biological reactions to wear debris in total joint replacement
Ingham, E., & Fisher, J. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535219 · Cited by 708
Aseptic loosening, not only a question of wear: A review of different theories
Sundfeldt, M., V Carlsson, L., B Johansson, C., Thomsen, P., & Gretzer, C. (2006) · Acta Orthopaedica · doi:10.1080/17453670610045902 · Cited by 622
Widespread dissemination of metal debris from implants
Case, C., Langkamer, V., James, C., Palmer, M., Kemp, A., Heap, P., & Solomon, L. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b5.8083255 · Cited by 444
Current Concepts Review - Wear in Total Hip and Knee Replacements*
SCHMALZRIED, T. P., & CALLAGHAN, J. J. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199901000-00016 · Cited by 395
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387
Metadata
- Authors
- Willert, H. ‐., & Semlitsch, M.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1977-03
- Volume
- 11
- Issue
- 2
- Pages
- 157-164
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2033376594
- Cited by
- 822
- References
- 0
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reactions of the articular capsule to wear products of artificial joint prostheses. https://app.cochat.ai/papers/10.1002/jbm.820110202
- The paper
- Willert, H. ‐., & Semlitsch, M. (1977). Reactions of the articular capsule to wear products of artificial joint prostheses. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820110202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.