The DOI matches its Crossref record.
Tissue response to dense apatite implants in rats
Abstract
Dense (97–99.9%) hydroxylapatite ceramics were implanted in muscle and bone tissue of rats. The aim of this study was to compare apatite implant material made of commercially available powder with laboratory powder prepared in a painstaking manner. Biocompatibility, biostability, and adherence to bone were evaluated. In muscle tissue the implants were found to be encapsulated with a very thin connective tissue layer. Implantation in excavated bone tissue resulted with new bone directly deposited against the implant surface, irrespective of the type of hydroxylapatite used. When the implants were protruding from the bone surface, bone appeared to grow up to the edge of the protruding part of the implant. A very strong bonding developed; push‐out tests indicated that the bone fractured but never at the interface. Histologic studies proved that a sleeve of newly formed bone closely encased the implant, regardless of shape. It was concluded that dense apatite ceramics are fully compatible with the tibia of the rat and that no degradation of the implant material occurred for intervals of up to 6 months after implantation. The very strong bonding without mechanical retention indicated continuity between artificial hydroxylapatite and natural bone. No difference was found between the biological behavior of the hydroxylapatites prepared from commercial or laboratory starting powders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Polymeric materials for bone and cartilage repair
Puppi, D., Chiellini, F., Piras, A. M., & Chiellini, E. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.01.006 · Cited by 913
Bonding of bone to apatite-coated implants
Geesink, R., de Groot, K., & Klein, C. (1988) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.70b1.2828374 · Cited by 537
Self-citationLyons, F. G., Al-Munajjed, A. A., Kieran, S. M., Toner, M. E., Murphy, C. M., Duffy, G. P., & O’Brien, F. J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.056 · Cited by 222
Reactions of cells at implant surfaces
van Blitterswijk, C. A., Bakker, D., Hesseling, S. C., & Koerten, H. K. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90198-j · Cited by 52
Metadata
- Authors
- Denissen, H. W., de Groot, K., Makkes, P. C., van den Hooff, A., & Klopper, P. J.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1980-11
- Volume
- 14
- Issue
- 6
- Pages
- 713-721
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2028251796
- Cited by
- 241
- References
- 0
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue response to dense apatite implants in rats. https://app.cochat.ai/papers/10.1002/jbm.820140603
- The paper
- Denissen, H. W., de Groot, K., Makkes, P. C., van den Hooff, A., & Klopper, P. J. (1980). Tissue response to dense apatite implants in rats. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820140603
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.