CoChat

Reactions of cells at implant surfaces

van Blitterswijk, Clemens A., Bakker, Dirkjan, Hesseling, Saco C., Koerten, Hendrik K. · 1991 · Biomaterials

The DOI matches its Crossref record; 50 of the 51 references it cites were found in a registry or an index.

Abstract

The surface of implants is an important parameter in host-implant integration. Several strategies can be used to obtain integration, such as the application of grooves or pores at the implant surface. Most of these surface alterations, however, will lead to an increase of total implant surface area which might influence the inflammatory response to an implant. As far as integration with bone is concerned several biomaterials have been successful in mimicking this material, by having similar crystals at their surface (calcium phosphate ceramics) or by containing a certain amount of calcium and phosphorus. Polyactive, a poly(ethylene oxide)-poly(butylene terephthalate) segmented copolymer, also possesses favourable integration properties with bone, but initially lacks calcium and phosphorus. It is proposed that the application of hydrogels as biomaterial may add a new dimension to integration capacity.

Overview

Integrity signals

Registry

Crossref · 10.1016/0142-9612(91)90198-j

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 50 references

Research works printed but not linked: 6

  1. van Blitterswijk, 1989, Intraperitoneal injection of five calcium phosphate ceramics, Vol. 3, 11
  2. van Blitterswijk, 1989, Biological performance of ceramics during inflammation and infection, CRC Crit. Rev. Biocomp, 5, 13
  3. Davies, J.E., The use of cell and tissue culture to investigate bone cell reactions to bioactive materials, in CRC Handbook of Bioactive Ceramics (Eds H.L.L Yamamura and J. Wilson) (in press)
  4. van Blitterswijk, 1989, Biomaterial/bone interactions: a comparative study, Trans. 15th Annu. Soc. Biomater., 107
  5. Bakker, 1989, The reactions of bone to Polyactive: a bone-bonding copolyether ester, Polymers Med. Surg., VI, 11
  6. Swart, J.G.N., Botverranging in het maxillo faciale gebied: een dierexperimenteel en klinisch onderzoel, PhD Thesis, Free University, Amsterdam, The Netherlands

Cited by

See all 61

Metadata

Authors
van Blitterswijk, C. A., Bakker, D., Hesseling, S. C., & Koerten, H. K.
Affiliations
Leiden University (NL)
Venue
Biomaterials
Publisher
Elsevier BV
Published
1991-03
Volume
12
Issue
2
Pages
187-193
ISSN
0142-9612 (ISSN-L)
OpenAlex
W1992939149
Cited by
52
References
51
Citations by year
2023: 2 · 2022: 1 · 2016: 3 · 2015: 1 · 2014: 1 · 2013: 1
FWCI
3.85
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
Keywords
implant surface modification, bone-implant interface, calcium phosphate ceramics, hydrogels, calcium and phosphorus content
MeSH terms
Adsorption, Animals, Biocompatible Materials, Calcium, Foreign-Body Reaction, Humans, Inflammation, Microscopy, Electron, Surface Properties, Osseointegration, Prostheses and Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reactions of cells at implant surfaces. https://app.cochat.ai/papers/10.1016/0142-9612(91)90198-j
The paper
van Blitterswijk, C. A., Bakker, D., Hesseling, S. C., & Koerten, H. K. (1991). Reactions of cells at implant surfaces. Biomaterials. https://doi.org/10.1016/0142-9612(91)90198-j

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.