The DOI matches its Crossref record.
Toxic reactions evoked by glutaraldehyde‐fixed pericardium and cardiac valve tissue bioprosthesis
Abstract
Bovine pericardial tissue and tissue‐derived bioprosthesis fixed in glutaraldehyde and stored in either glutaraldehyde or formaldehyde can induce cytotoxic reactions even after prolonged washing due to the slow leaching of the chemicals used for crosslinking and sterilizing. Sequential rinsing for up to 60 min was still not sufficient to eliminate cytotoxic effects. On the other hand, satisfactory results were obtained when cardiac valves made from glutaraldehyde fixed pericardium were stored in a solution containing 0.02% of propyl‐hydroxy‐benzoate and 0.18% methyl‐hydroxy‐benzoate. The valves stored in this solution and rinsed three times for 1 min in normal saline showed few signs of residual cytotoxicity. Rinsing in a solution containing glycine was partially effective in neutralizing the cytotoxic effect, and this or similar approaches offer good possibilities. The use of Chang cells grown in culture provides an excellent quantitative assay for the assessment of residual cytotoxicity and for evaluating the host response to different methods of fixation, storage, and rinsing of tissue derived bioprosthesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cell-laden microengineered gelatin methacrylate hydrogels
Nichol, J. W., Koshy, S. T., Bae, H., Hwang, C. M., Yamanlar, S., & Khademhosseini, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.064 · Cited by 2,377
Biocompatibility of hydrogel-based scaffolds for tissue engineering applications
Naahidi, S., Jafari, M., Logan, M., Wang, Y., Yuan, Y., Bae, H., Dixon, B., & Chen, P. (2017) · Biotechnology Advances · doi:10.1016/j.biotechadv.2017.05.006 · Cited by 907
Acellular vascular tissues: natural biomaterials for tissue repair and tissue engineering
Schmidt, C. E., & Baier, J. M. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00148-4 · Cited by 762
Tissue heart valves: Current challenges and future research perspectives
Schoen, F. J., & Levy, R. J. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19991215)47:4<439::aid-jbm1>3.0.co;2-o · Cited by 498
Glutaraldehyde as a fixative in bioprostheses and drug delivery matrices
Jayakrishnan, A., & Jameela, S. R. (1996) · Biomaterials · doi:10.1016/0142-9612(96)82721-9 · Cited by 498
Methods for the treatment of collagenous tissues for bioprostheses
Khor, E. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00106-8 · Cited by 415
Chemically modified collagen: A natural biomaterial for tissue replacement
Nimni, M. E., Cheung, D., Strates, B., Kodama, M., & Sheikh, K. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210606 · Cited by 392
Self-citationHaugh, M. G., Murphy, C. M., McKiernan, R. C., Altenbuchner, C., & O'Brien, F. J. (2011) · Tissue Engineering Part A · doi:10.1089/ten.tea.2010.0590 · Cited by 330
Immobilization of heparin to EDC/NHS-crosslinked collagen. Characterization and in vitro evaluation
Wissink, M. J. B., Beernink, R., Pieper, J. S., Poot, A. A., Engbers, G. H. M., Beugeling, T., van Aken, W. G., & Feijen, J. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00164-2 · Cited by 311
Transglutaminase crosslinked gelatin as a tissue engineering scaffold
Yung, C. W., Wu, L. Q., Tullman, J. A., Payne, G. F., Bentley, W. E., & Barbari, T. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31431 · Cited by 290
The use of thermal techniques for the characterization and selection of natural biomaterials
Samouillan, V., Delaunay, F., Dandurand, J., Merbahi, N., Gardou, J.-P., Yousfi, M., Gandaglia, A., Spina, M., & Lacabanne, C. (2011) · Journal of Functional Biomaterials · doi:10.3390/jfb2030230 · Cited by 111
McDade, J. K., Brennan-Pierce, E. P., Ariganello, M. B., Labow, R. S., & Michael Lee, J. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.02.021 · Cited by 80
Koch, H., Graneist, C., Emmrich, F., Till, H., Metzger, R., Aupperle, H., Schierle, K., Sack, U., & Boldt, A. (2012) · Journal of Biomedicine and Biotechnology · doi:10.1155/2012/948320 · Cited by 37
Metadata
- Authors
- Gendler, E., Gendler, S., & Nimni, M. E.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1984-09
- Volume
- 18
- Issue
- 7
- Pages
- 727-736
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2121596563
- Cited by
- 175
- References
- 0
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.