The DOI matches its Crossref record.
Biodegradation of and tissue reaction to 50:50 poly(DL‐lactide‐co‐glycolide) microcapsules
Abstract
The biodegradation of the copolymer 50:50 poly(DL‐lactide‐CO‐glycolide)‐lypressin microcapsules was studied by light and electron microscopic methods and 14 C release. Intramuscular injection sites of microcapsules in rats were studied by dissecting and conventional light microscopy as well as scanning (SEM) and transmission electron microscopy. A minimal localized acute myositis was seen initially at the injection sites. By Day 4, a few small foreign body giant cells were present participating in the minimal foreign body response. Later the inflammatory cells decreased and the individual microcapsules were walled off by immature fibrous connective tissue and large syncytial foreign body giant cells. By Day 35, definitive changes in some microcapsules, consisting of a granular and slightly eroded appearance of the internal matrix, were seen by SEM. By Day 42, the outer rims of the microcapsules were extensively eroded. At Day 56, the inflammatory and connective tissue reactions were almost completely resolved and biodegradation continued so that only remnant pieces of the microcapsules were present at Day 63. The morphologic picture correlated well with loss of 14 C radioactivity, which could no longer be detected at the injection sites on Day 56. Phagocytosis did not seem to be an important factor in the biodegradation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617
Wei, G., & Ma, P. X. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.005 · Cited by 1,271
Biodegradable Polymers-A Review on Recent Trends and Emerging Perspectives
Luckachan, G. E., & Pillai, C. K. S. (2011) · Journal of Polymers and the Environment · doi:10.1007/s10924-011-0317-1 · Cited by 767
Li, S. M., Garreau, H., & Vert, M. (1990) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00700871 · Cited by 733
More about the degradation of LA/GA-derived matrices in aqueous media
Vert, M., Li, S., & Garreau, H. (1991) · Journal of Controlled Release · doi:10.1016/0168-3659(91)90027-b · Cited by 295
Metadata
- Authors
- Visscher, G. E., Robison, R. L., Maulding, H. V., Fong, J. W., Pearson, J. E., & Argentieri, G. J.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1985-03
- Volume
- 19
- Issue
- 3
- Pages
- 349-365
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2007635182
- Cited by
- 221
- References
- 0
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biodegradation of and tissue reaction to 50:50 poly(DL‐lactide‐co‐glycolide) microcapsules. https://app.cochat.ai/papers/10.1002/jbm.820190315
- The paper
- Visscher, G. E., Robison, R. L., Maulding, H. V., Fong, J. W., Pearson, J. E., & Argentieri, G. J. (1985). Biodegradation of and tissue reaction to 50:50 poly(DL‐lactide‐co‐glycolide) microcapsules. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820190315
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.