The measurement of contact angles on circular tubing surfaces using the captive bubble technique
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Circular tubings are used extensively in biomedical implants and devices. It is desirable to determine contact angles on the inner or outer surfaces of such tubing in its final fabricated form. In this study, a technique for the measurement of contact angles on tubing surfaces in an aqueous environment is reported. This has particular applications to biomaterials research, where polymer tubings contact the biologic environment. In this technique, air or octane captive bubble dimensions can be measured, and an underwater contact angle calculated from these dimensions. The validity of the technique was experimentally confirmed using Solution Grade Biomer and NIH standard polyethylene surfaces.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Variations in PEU blood compatibility have been observed, with improved thromboresistance correlating to more alkylated soft segments [82], higher soft segment content on the surface [83] and surface treatment, such as grafted sulfonate groups [84,85].”
From Shape-memory polymers as a technology platform for biomedical applications (2010) · cites this paper as [84]
Citations
Cites
A technique for the characterization of hydrophilic solid surfaces
Hamilton, W. C. (1972) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(72)90011-2 · Cited by 200
Contact angles at the solid—water interface
Andrade, J. D., Ma, S. M., King, R. N., & Gregonis, D. E. (1979) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(79)90350-3 · Cited by 188
Physicochemical characterization and in vivo blood tolerability of cast and extruded biomer
Lelah, M. D., Lambrecht, L. K., Young, B. R., & Cooper, S. L. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170102 · Cited by 134
Self-citation
Research works printed but not linked: 2
- Andrade J. D., 1981, Blood‐Material interactions—20 years of frustration, Trans. Am. Soc. Artif. Int. Orgs., 27, 659
- R. N.King “Protocol for contact angle measurements at the polymerwater interface in Guidelines for physicochemical characterization of biomaterials ” NHLBI Report NIH Publication No. 80–2186 1980 pp.105–106.
Cited by
Shape-memory polymers as a technology platform for biomedical applications
Lendlein, A., Behl, M., Hiebl, B., & Wischke, C. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.8 · Cited by 469
Properties and biological inteactions of polyurethane anionomers: Effect of sulfonate incorporation
Grasel, T. G., & Cooper, S. L. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230304 · Cited by 179
Self-citationPolymers for cell/tissue anti-adhesion
Lih, E., Oh, S. H., Joung, Y. K., Lee, J. H., & Han, D. K. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2014.10.004 · Cited by 169
Platelet shape change and cytoskeletal reorganization on polyurethaneureas
Goodman, S. L., Grasel, T. G., Cooper, S. L., & Albrecht, R. M. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230109 · Cited by 155
Self-citationSurface properties and blood compatibility of polyurethaneureas
Grasel, T. G., & Cooper, S. L. (1986) · Biomaterials · doi:10.1016/0142-9612(86)90002-5 · Cited by 122
Self-citationGrasel, T. G., Pierce, J. A., & Cooper, S. L. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210702 · Cited by 120
Self-citationFabrizius‐Homan, D. J., & Cooper, S. L. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250804 · Cited by 111
Self-citationEx vivo interactions and surface property relationships of polyetherurethanes
Lelah, M. D., Grasel, T. G., Pierce, J. A., & Cooper, S. L. (1986) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820200403 · Cited by 90
Self-citationSilver, J. H., Lin, J., Lim, F., Tegoulia, V. A., Chaudhury, M. K., & Cooper, S. L. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00173-2 · Cited by 89
“[33].”
Self-citationMeasurement of bacterial growth rates on polymers
Barton, A. J., Sagers, R. D., & Pitt, W. G. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199610)32:2<271::aid-jbm17>3.0.co;2-m · Cited by 45
Effect of surface hydrophilicity on ex vivo blood compatibility of segmented polyurethanes
Takahara, A., Okkema, A. Z., Cooper, S. L., & Coury, A. J. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90042-9 · Cited by 78
Self-citationStaphylococcus epidermidis adhesion on hydrophobic and hydrophilic textured biomaterial surfaces
Xu, L.-C., & Siedlecki, C. A. (2014) · Biomedical Materials · doi:10.1088/1748-6041/9/3/035003 · Cited by 75
“The contact angles of an air bubble on the PUU film surfaces immersed in purified water were measured by injecting an air bubble from a syringe (Hamilton) with a bent needle (22G, BD) using a goniometer [40, 41].”
MethodLin, J., & Cooper, S. L. (1995) · Biomaterials · doi:10.1016/0142-9612(95)94910-d · Cited by 75
Self-citationOkkema, A. Z., Visser, S. A., & Cooper, S. I. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820251106 · Cited by 69
Self-citationOkkema, A. Z., Grasel, T. G., Zdrahala, R. J., Solomon, D. D., & Cooper, S. L. (1989) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856289x00055 · Cited by 61
Self-citationPhysical and blood contacting characteristics of propyl sulphonate grafted Biomer
Okkema, A. Z., Yu, X.-H., & Cooper, S. L. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90123-r · Cited by 57
Self-citationOkkema, A. Z., & Cooper, S. L. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90115-q · Cited by 55
Self-citationSynthesis, characterization and ex vivo evaluation of poly-dimethylsiloxane polyurea-urethanes
Lim, F., Yang, C.-Z., & Cooper, S. L. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90218-6 · Cited by 54
Self-citationTakahara, A., Okkema, A. Z., Wabers, H. D., & Cooper, S. L. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250905 · Cited by 51
Self-citationOkkema, A. Z., FABRIZIUS, D. J., Grasel, T. G., Cooper, S. L., & Zdrahala, R. J. (1989) · Biomaterials · doi:10.1016/0142-9612(89)90005-7 · Cited by 43
Self-citationSurface and blood‐contacting properties of alkylsiloxane monolayers supported on silicone rubber
Silver, J. H., Hergenrother, R. W., Lin, J., Lim, F., Lin, H., Okada, T., Chaudhury, M. K., & Cooper, S. L. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290414 · Cited by 36
Self-citationEffect of polyol type on the surface structure of sulfonate‐containing polyurethanes
Silver, J. H., Lewis, K. B., Ratner, B. D., & Cooper, S. L. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270606 · Cited by 36
Self-citationLoading and Release of a Phospholipid From Contact Lenses
Pitt, W. G., Jack, D. R., Zhao, Y., Nelson, J. L., & Pruitt, J. D. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e31820e9ff8 · Cited by 32
“Lens wettability was assessed by underwater contact angles of air and octane,(20) following procedures reported previously for curved surfaces.(21) The lenses were sliced with a clean razor in 1/3 sections, and the middle section attached by the anterior surface to a polypropylene lens mold (female mold) that was also…”
MethodShanker, R. M., Ahmed, I., Bourassa, P., & Carola, K. V. (1995) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(94)00381-e · Cited by 28
Grasel, T. G., Castner, D. G., Ratner, B. D., & Cooper, S. L. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240507 · Cited by 23
Self-citationSynthesis and physical properties of poly(fluoroalkylether)urethanes
Yu, X., Okkema, A. Z., & Cooper, S. L. (1990) · Journal of Applied Polymer Science · doi:10.1002/app.1990.070410734 · Cited by 23
Self-citationGrasel, T. G., Pitt, W. G., Murthy, K. D., McCoy, T. J., & Cooper, S. L. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90002-0 · Cited by 18
Self-citationGrasel, T. G., Lee, D. C., Okkema, A. Z., Slowinski, T. J., & Cooper, S. L. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90001-4 · Cited by 17
Self-citationLim, F., Xuehai, Y., & Cooper, S. L. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90243-u · Cited by 17
Self-citationEffect of protein adsorption on the blood-contacting response of sulphonated polyurethanes
Silver, J. H., Lin, H., & Cooper, S. L. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90005-m · Cited by 15
Self-citationTransport of Phospholipid in Silicone Hydrogel Contact Lenses
Pitt, W. G., Jack, D. R., Zhao, Y., Nelson, J. L., & Pruitt, J. D. (2011) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/092050611x554174 · Cited by 14
Effect of sulphonate incorporation on in vitro leucocyte adhesion to polyurethanes
Lim, F., & Cooper, S. L. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98818-y · Cited by 13
Self-citationBiostability and blood-contacting properties of sulfonate grafted polyurethane and Biomer
Wabers, H. D., McCoy, T. J., Okkema, A. Z., Hergenrother, R. W., Wolf, M. F., & Cooper, S. L. (1993) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856292x00349 · Cited by 12
Self-citationTakahara, A., Jo, N., Takamori, K., & Kajiyama, T. (1990) · Springer eBooks · doi:10.1007/978-1-4899-0768-4_23 · Cited by 12
Chemical Modification of Polyurethanes by Radiation-Induced Grafting
Jansen, B. (1986) · Journal of Biomaterials Applications · doi:10.1177/088532828600100305 · Cited by 11
Thrombus deposition on polyurethanes designed for biomedical applications
Wabers, H. D., Hergenrother, R. W., Coury, A. J., & Cooper, S. L. (1992) · Journal of Applied Biomaterials · doi:10.1002/jab.770030302 · Cited by 10
Self-citationEffect of a Hydrophobic Phospholipid Lining of the Gastric Mucosa in Bioadhesion
Park, J. H., & Robinson, J. R. (2007) · Pharmaceutical Research · doi:10.1007/s11095-007-9353-x · Cited by 7
“Contact angles were measured by the Bcaptive bubble technique^ (15) in an aqueous environment.”
MethodLendlein, A., Razzaq, M. Y., Wischke, C., Kratz, K. L., Heuchel, M., Zotzmann, J., Hiebl, B., Neffe, A. T., & Behl, M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.10213-9 · Cited by 5
Lendlein, A., Wischke, C., Kratz, K. L., Heuchel, M., Zotzmann, J., Hiebl, B., Neffe, A. T., & Behl, M. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-055294-1.00271-3 · Cited by 8
Contact Angles and Surface Free Energies of Solids
Baszkin, A. (1993) · Springer eBooks · doi:10.1007/978-94-011-1640-4_23 · Cited by 5
Ionic Polyurethanes: Surface and Blood-Contacting Properties
Okkema, A. Z., Giroux, T. A., Grasel, T. G., & Cooper, S. L. (1987) · MRS Proceedings · doi:10.1557/proc-110-91 · Cited by 5
Self-citationImmunogold staining of fibrinogen on biomaterial surfaces: the effect of labeling conditions
Murthy, K. D., Simmons, S. R., Albrecht, R. M., & Cooper, S. L. (1988) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(88)90067-7 · Cited by 2
Self-citationUnderwater captive bubble technique on curved surfaces of blended polydimethylsiloxanes
Angu, E. A., Cameron, R. C., Pollack, S. K., & Collins, W. E. (1999) · Journal of Adhesion Science and Technology · doi:10.1163/156856199x00893 · Cited by 1
Metadata
- Authors
- Lelah, M. D., Grasel, T. G., Pierce, J. A., & Cooper, S. L.
- Affiliations
- University of Wisconsin–Madison (US)
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1985-11
- Volume
- 19
- Issue
- 9
- Pages
- 1011-1015
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2152599914
- Cited by
- 43
- References
- 3
- Citations by year
- 2017: 1 · 2014: 2
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (HL21001)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Surface Modification and Superhydrophobicity
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Physical Sciences › Chemical Engineering › Filtration and Separation › Minerals Flotation and Separation Techniques
- Keywords
- contact angle measurement, biomaterials, biomedical implants, polyethylene surfaces, Biomer, aqueous environment
- MeSH terms
- Air, Biocompatible Materials, Humans, Surface Properties, Water, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.