Abstract

The cellular biocompatibility of low‐density polyethylene and a cytotoxic polyvinylchloride were investigated using an in vivo cage implant system. Components of the inflammatory response (white cells, extracellular alkaline and acid phosphatase, the complement component C3, and total protein content) were monitored over a 21‐day implantation period. Scanning electron microscopy was used to evaluate the morphologic condition of leukocytes adherent to the implanted polymers. Prior to implantation, each polymer was evaluated using an established primary acute toxicity screen. The results showed that the cytotoxic polyvinylchloride stimulated an intense acute phase inflammatory response, and at later observation periods, an intense and increasing chronic inflammatory response. In constrast, the polyethylene promoted relatively small increases in the acute and chronic phases of inflammation; the overall cellular response being essentially resolved by the third week after implantation. The initial toxicity screen of each polymer suggested that the observed differences in inflammation were primarily caused by the release from the polyvinylchloride of the added cytotoxic agent (dioctyltinbisoctylmercaptoacetate).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820200105

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 60

Metadata

Authors
Marchant, R. E., Anderson, J. M., & Dillingham, E. O.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1986-01
Volume
20
Issue
1
Pages
37-50
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2116660863
Cited by
60
References
1
FWCI
4.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vivo biocompatibility studies. VII. Inflammatory response to polyethylene and to a cytotoxic polyvinylchloride. https://app.cochat.ai/papers/10.1002/jbm.820200105
The paper
Marchant, R. E., Anderson, J. M., & Dillingham, E. O. (1986). In vivo biocompatibility studies. VII. Inflammatory response to polyethylene and to a cytotoxic polyvinylchloride. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820200105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.