CoChat

Tissue/biomaterial interface characteristics of four elastomers. A transmission electron microscopical study

Bakker, D., van Blitterswijk, C. A., Hesseling, S. C., Daems, W. Th., Grote, J. J. · 1990 · Journal of Biomedical Materials Research

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Abstract

The tissue/biomaterial interface reactions of four elastomers—selected as candidates for scaffolding for tympanic membrane tissue in a total alloplastic middle ear prosthesis—were studied at the electron microscopical level after implantation in the rat middle ear. Time‐dependent changes in the phagocyte/polymer interface suggested degradation of porous implants made of Estane polyether urethane, polypropylene oxide, and a poly(ethylene oxide hydantoin) and poly(tetramethylene terephthalate) segmented polyether polyester copolymer (HPOE/PBT copolymer), but not of dense Silastic silicone rubber implants. Silastic was always encapsulated in fibrous tissue. Contact between fibrous tissue and HPOE/PBT copolymer or Estane was established in the third month, but fibrous tissue was never seen close to polypropylene oxide. Bone made contact only with Estane and HPOE/PBT copolymer implants. The bone/copolymer interface showed an electron‐dense layer morphologically similar to that seen between bone and hydroxyapatite ceramic, suggesting that with respect to bone HPOE/PBT copolymer behaves like a bioactive implant material. The electron‐dense layer was absent at the bone/Estane interface. Estane and especially HPOE/PBT copolymer seem to be suitable as alloplastic tympanic membrane because of their interface behavior with respect to fibrous tissue and bone.

Overview

Integrity signals

Registry

Crossref · 10.1002/jbm.820240302

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Research works printed but not linked: 12

  1. Jarcho M., 1977, Tissue cellular, and subcellular events at a bone ceramic hydroxyapatite interface, J. Bioeng., 1, 79
  2. Osborn J. F., 1980, Dental Implants, 111
  3. de Wijn J. R., 1981, Biocompatibility of Clinical Implant Materials, II, 99
  4. Chambers T. J., 1981, Fundamental Aspects of Biocompatibility I, 145
  5. Rae T., 1981, Fundamental Aspects of Biocompatibility I, 159
  6. Daems W. Th., 1980, The Reticuloendothelial System I, A Comprehensive Treatise, 57
  7. Kopecek J., 1983, Prog. Polym. Sci., 1
  8. J. G. F.Bots “Polyethers as biomaterials ” Thesis Technical University of Twente Enschede The Netherlands 1988.
  9. K. B.Stokes A. W.Frazer andE. A.Carter “The biostability of various polyetherurethanes under stress ” Prep. 42nd Annu. Tech. Conf. Soc. Plast. Eng. 30 Washington D.C. 1073(1984).
  10. Griss P., 1980, Mechanical Properties of Biomaterials, 217
  11. Williams D. F., 1978, Implants in Surgery, 203
  12. Hench L. L., 1981, Fundamental Aspects of Biocompatibility, 67

Cited by

See all 49

Metadata

Authors
Bakker, D., van Blitterswijk, C. A., Hesseling, S. C., Daems, W. T., & Grote, J. J.
Affiliations
  • Leiden University Medical Center (NL)
  • Leiden University (NL)
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1990-03
Volume
24
Issue
3
Pages
277-293
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2074433667
Cited by
49
References
46
Citations by year
2024: 1 · 2023: 1 · 2015: 1 · 2014: 1
FWCI
5.17
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Biomedical Materials Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
Keywords
elastomers, polypropylene glycol, implant degradation, fibrous tissue encapsulation
MeSH terms
Animals, Biocompatible Materials, Male, Materials Testing, Microscopy, Electron, Rats, Inbred Strains, Rubber, Tympanic Membrane, Prostheses and Implants, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.