Tissue/biomaterial interface characteristics of four elastomers. A transmission electron microscopical study
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
The tissue/biomaterial interface reactions of four elastomers—selected as candidates for scaffolding for tympanic membrane tissue in a total alloplastic middle ear prosthesis—were studied at the electron microscopical level after implantation in the rat middle ear. Time‐dependent changes in the phagocyte/polymer interface suggested degradation of porous implants made of Estane polyether urethane, polypropylene oxide, and a poly(ethylene oxide hydantoin) and poly(tetramethylene terephthalate) segmented polyether polyester copolymer (HPOE/PBT copolymer), but not of dense Silastic silicone rubber implants. Silastic was always encapsulated in fibrous tissue. Contact between fibrous tissue and HPOE/PBT copolymer or Estane was established in the third month, but fibrous tissue was never seen close to polypropylene oxide. Bone made contact only with Estane and HPOE/PBT copolymer implants. The bone/copolymer interface showed an electron‐dense layer morphologically similar to that seen between bone and hydroxyapatite ceramic, suggesting that with respect to bone HPOE/PBT copolymer behaves like a bioactive implant material. The electron‐dense layer was absent at the bone/Estane interface. Estane and especially HPOE/PBT copolymer seem to be suitable as alloplastic tympanic membrane because of their interface behavior with respect to fibrous tissue and bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Bonding mechanisms at the interface of ceramic prosthetic materials
Hench, L. L., Splinter, R. J., Allen, W. C., & Greenlee, T. K. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050611 · Cited by 3,251
The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone
BOBYN, J. D., PILLIAR, R. M., CAMERON, H. U., & WEATHERLY, G. C. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00045 · Cited by 832
Aliphatic polyesters. I. The degradation of poly(ϵ‐caprolactone) in vivo
Pitt, C. G., Chasalow, F. I., Hibionada, Y. M., Klimas, D. M., & Schindler, A. (1981) · Journal of Applied Polymer Science · doi:10.1002/app.1981.070261124 · Cited by 712
Application of porous ceramics for the attachment of load bearing internal orthopedic applications
Klawitter, J. J., & Hulbert, S. F. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050613 · Cited by 634
Biomaterials : an interfacial approach
Hench, L. L., & Ethridge, E. C. (1982) · Academic Press eBooks · Cited by 487
Collagen: Molecular Diversity in the Body's Protein Scaffold
Eyre, D. R. (1980) · Science · doi:10.1126/science.7355290 · Cited by 451
The intracellular degradation of poly(ε‐caprolactone)
Woodward, S. C., Brewer, P. S., Moatamed, F., Schindler, A., & Pitt, C. G. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190408 · Cited by 380
Fundamental aspects of biocompatibility
Williams, D. F. (1981) · CRC Press eBooks · Cited by 301
Biodegradation of and tissue reaction to 50:50 poly(DL‐lactide‐co‐glycolide) microcapsules
Visscher, G. E., Robison, R. L., Maulding, H. V., Fong, J. W., Pearson, J. E., & Argentieri, G. J. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190315 · Cited by 221
Clark, A. E., Hench, L. L., & Paschall, H. A. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100202 · Cited by 212
Biodegradation of surgical polymers
Williams, D. F. (1982) · Journal of Materials Science · doi:10.1007/bf00752233 · Cited by 211
Courtney, J. M. (1981) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(81)90094-7 · Cited by 207
Macropore tissue ingrowth: a quantitative and qualitative study on hydroxyapatite ceramic
van Blitterswijk, C. A., Grote, J. J., Kuijpers, W., Daems, W. T., & de Groot, K. (1986) · Biomaterials · doi:10.1016/0142-9612(86)90071-2 · Cited by 198
Self-citationSurface science aspects on inorganic biomaterials
Kasemo, B., & Lausmaa, J. (1986) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 181
Some aspects of macrophage behavior at the implant interface
Salthouse, T. N. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180407 · Cited by 176
Bioreactions at the tissue/ hydroxyapatite interface
van Blitterswijk, C. A., Grote, J. J., Kuÿpers, W., Blok-van Hoek, C. J. G., & Daems, W. T. (1985) · Biomaterials · doi:10.1016/0142-9612(85)90020-1 · Cited by 174
Self-citationThe enzymatic degradation of polymers in vitro
Smith, R., Oliver, C., & Williams, D. F. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210805 · Cited by 139
The lamina limitans of the organic matrix of calcified cartilage and bone
Scherft, J. P. (1972) · Journal of Ultrastructure Research · doi:10.1016/s0022-5320(72)90008-1 · Cited by 122
Spector, M., Michno, M. J., Smarook, W. H., & Kwiatkowski, G. T. (1978) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820120508 · Cited by 114
Quantitative characterization of cells at the interface of long‐term implants of selected polymers
Behling, C. A., & Spector, M. (1986) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820200509 · Cited by 100
Corrosion of Implant Materials
Williams, D. F. (1976) · Annual Review of Materials Science · doi:10.1146/annurev.ms.06.080176.001321 · Cited by 100
Reed, A. M., & Gilding, D. K. (1981) · Polymer · doi:10.1016/0032-3861(81)90169-5 · Cited by 99
Effect of implantation site on phagocyte/polymer interaction and fibrous capsule formation
Bakker, D., van Blitterswijk, C., Hesseling, S. C., Grote, J. J., & Daems, W. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90064-6 · Cited by 86
Self-citationThe effect of implantation on the physical properties of silicone rubber
Swanson, J. W., & LeBeau, J. E. (1974) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820080603 · Cited by 85
Ultrastructure of Durapatite‐Periodontal Tissue Interface in Human Intrabony Defects
Ganeles, J., Listgarten, M. A., & Evian, C. I. (1986) · Journal of Periodontology · doi:10.1902/jop.1986.57.3.133 · Cited by 78
Bakker, D., van Blitterswijk, C. A., Hesseling, S. C., Koerten, H. K., Kuijpers, W., & Grote, J. J. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240407 · Cited by 74
Self-citationUltrastructural observations of cells at the interface of a biodegradable polymer: Polyglactin 910
Matlaga, B. F., & Salthouse, T. N. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170115 · Cited by 72
The role of porous polymeric materials in prosthesis attachment
Sauer, B. W., WEINSTEIN, A. M., Klawitter, J. J., Hulbert, S., Leonard, R. B., & Bagwell, J. (1974) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820080315 · Cited by 68
Durability of Silicone Implants —An In Vivo Study
Swanson, A. B., Meester, W. D., Swanson, G. D. G., Rangaswamy, L., & Schut, G. E. D. (1973) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(20)30840-3 · Cited by 59
1984 Santa Barbara State-of-the-Art Symposium on Otosclerosis: Results, Conclusions, Consensus
Smith, M. F. W., & Hopp, M. L. (1986) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348948609500101 · Cited by 56
Bone growth into porous carbon, polyethylene, and polypropylene prostheses
Cestro, H. J., Salyer, K. E., & Toranto, I. R. (1975) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820090403 · Cited by 54
The Reticuloendothelial System: A Comprehensive Treatise
Christmas, S. E. (1985) · British Journal of Cancer · doi:10.1038/bjc.1985.90 · Cited by 45
Biocompatibility of six elastomers in vitro
Bakker, D., van Blitterswijk, C., Daems, W., & Grote, J. J. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820220506 · Cited by 42
Self-citationHydroxyapatite Ceramic as Middle Ear Implant Material: Animal Experimental Results
Grote, J. J., van Blitterswijk, C., & Kuijpers, W. (1986) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894860950s201 · Cited by 39
Self-citationSmall diameter blood vessel prostheses from blends of polyethylene oxide and polypropylene oxide
Bots, J. G., van der Does, L., & Bantjes, A. (1986) · Biomaterials · doi:10.1016/0142-9612(86)90011-6 · Cited by 39
The specificity of polymer degradation in the living body
Moiseev, Y. V., Tt, D., Voronkova, O. S., Gumargalieva, K. Z., & Privalova, L. G. (1979) · Journal of Polymer Science Polymer Symposia · doi:10.1002/polc.5070660127 · Cited by 39
van Blitterswijk, C., Grote, J. J., Koerten, H. K., & Kuijpers, W. (1986) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820200810 · Cited by 31
Self-citationStructure–property relationships of a new series of segmented polyether–polyester copolymers
Mody, P. C., Wilkes, G. L., & Wagener, K. B. (1981) · Journal of Applied Polymer Science · doi:10.1002/app.1981.070260904 · Cited by 29
Polymer Osteosynthesis: A Clinical Trial of Ostamer in Forty-two Patients
Redler, I. (1962) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-196244080-00010 · Cited by 29
Selective release of lysosomal enzymes from cell populations containing multinucleate giant cells
Papadimitriou, J. M., & Wee, S. H. (1976) · The Journal of Pathology · doi:10.1002/path.1711200402 · Cited by 28
Ceramics, glasses, and composites in medicine.
Hench, L. (1973) · PubMed · Cited by 26
In vivo degradation of silicone rubber poppets in prosthetic heart valves
Cuddihy, E. F., MOACANIN, J., Roschke, E. J., & Harrison, E. C. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100314 · Cited by 21
BIODEGRADABLE ELASTOMERIC BIOMATERIALS — POLYETHYLENE OXIDE/POLYETHYLENE TEREPHTHALATE COPOLYMERS
Reed, A. M., Gilding, D. K., & Wilson, J. (1977) · ASAIO Journal · doi:10.1097/00002480-197700230-00032 · Cited by 17
Tympanoplasty with Calciumphosphate
Grote, J. J. (1984) · Springer eBooks · doi:10.1007/978-94-009-6756-4_32 · Cited by 15
Self-citationBehaviour of Bioimplants in the Middle Ear. an Experimental Study
Kuijpers, W. (1984) · Springer eBooks · doi:10.1007/978-94-009-6756-4_3 · Cited by 13
Exocytosis by macrophage polykarya: An ultrastructural study
Papadimitriou, J. M., & Robertson, T. A. (1980) · The Journal of Pathology · doi:10.1002/path.1711300203 · Cited by 13
Research works printed but not linked: 12
- Jarcho M., 1977, Tissue cellular, and subcellular events at a bone ceramic hydroxyapatite interface, J. Bioeng., 1, 79
- Osborn J. F., 1980, Dental Implants, 111
- de Wijn J. R., 1981, Biocompatibility of Clinical Implant Materials, II, 99
- Chambers T. J., 1981, Fundamental Aspects of Biocompatibility I, 145
- Rae T., 1981, Fundamental Aspects of Biocompatibility I, 159
- Daems W. Th., 1980, The Reticuloendothelial System I, A Comprehensive Treatise, 57
- Kopecek J., 1983, Prog. Polym. Sci., 1
- J. G. F.Bots “Polyethers as biomaterials ” Thesis Technical University of Twente Enschede The Netherlands 1988.
- K. B.Stokes A. W.Frazer andE. A.Carter “The biostability of various polyetherurethanes under stress ” Prep. 42nd Annu. Tech. Conf. Soc. Plast. Eng. 30 Washington D.C. 1073(1984).
- Griss P., 1980, Mechanical Properties of Biomaterials, 217
- Williams D. F., 1978, Implants in Surgery, 203
- Hench L. L., 1981, Fundamental Aspects of Biocompatibility, 67
Cited by
Modification of polysiloxane polymers for biomedical applications: a review
Abbasi, F., Mirzadeh, H., & Katbab, A. (2001) · Polymer International · doi:10.1002/pi.783 · Cited by 500
Shape-memory polymers as a technology platform for biomedical applications
Lendlein, A., Behl, M., Hiebl, B., & Wischke, C. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.8 · Cited by 469
Gomes, P. S., & Fernandes, M. H. (2011) · Laboratory Animals · doi:10.1258/la.2010.010085 · Cited by 291
The ultrastructure of the bone‐hydroxyapatite interface in vitro
de Bruijn, J. D., Klein, C. P. A. T., de Groot, K., & van Blitterswijk, C. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820261008 · Cited by 134
Histological evaluation of a biodegradable polyactive®/ hydroxyapatite membrane
Jansen, J. A., de Ruijter, J. E., Janssen, P. T. M., & Paquay, Y. C. G. J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)94142-8 · Cited by 81
Metadata
- Authors
- Bakker, D., van Blitterswijk, C. A., Hesseling, S. C., Daems, W. T., & Grote, J. J.
- Affiliations
- Leiden University Medical Center (NL)
- Leiden University (NL)
- ORCID
- Daems, W. Th.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1990-03
- Volume
- 24
- Issue
- 3
- Pages
- 277-293
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2074433667
- Cited by
- 49
- References
- 46
- Citations by year
- 2024: 1 · 2023: 1 · 2015: 1 · 2014: 1
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Keywords
- elastomers, polypropylene glycol, implant degradation, fibrous tissue encapsulation
- MeSH terms
- Animals, Biocompatible Materials, Male, Materials Testing, Microscopy, Electron, Rats, Inbred Strains, Rubber, Tympanic Membrane, Prostheses and Implants, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.