Tissue/biomaterial interface characteristics of four elastomers. A transmission electron microscopical study
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
The tissue/biomaterial interface reactions of four elastomers—selected as candidates for scaffolding for tympanic membrane tissue in a total alloplastic middle ear prosthesis—were studied at the electron microscopical level after implantation in the rat middle ear. Time‐dependent changes in the phagocyte/polymer interface suggested degradation of porous implants made of Estane polyether urethane, polypropylene oxide, and a poly(ethylene oxide hydantoin) and poly(tetramethylene terephthalate) segmented polyether polyester copolymer (HPOE/PBT copolymer), but not of dense Silastic silicone rubber implants. Silastic was always encapsulated in fibrous tissue. Contact between fibrous tissue and HPOE/PBT copolymer or Estane was established in the third month, but fibrous tissue was never seen close to polypropylene oxide. Bone made contact only with Estane and HPOE/PBT copolymer implants. The bone/copolymer interface showed an electron‐dense layer morphologically similar to that seen between bone and hydroxyapatite ceramic, suggesting that with respect to bone HPOE/PBT copolymer behaves like a bioactive implant material. The electron‐dense layer was absent at the bone/Estane interface. Estane and especially HPOE/PBT copolymer seem to be suitable as alloplastic tympanic membrane because of their interface behavior with respect to fibrous tissue and bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Bonding mechanisms at the interface of ceramic prosthetic materials
Hench, L. L., Splinter, R. J., Allen, W. C., & Greenlee, T. K. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050611 · Cited by 3,251
The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone
BOBYN, J. D., PILLIAR, R. M., CAMERON, H. U., & WEATHERLY, G. C. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00045 · Cited by 832
Aliphatic polyesters. I. The degradation of poly(ϵ‐caprolactone) in vivo
Pitt, C. G., Chasalow, F. I., Hibionada, Y. M., Klimas, D. M., & Schindler, A. (1981) · Journal of Applied Polymer Science · doi:10.1002/app.1981.070261124 · Cited by 712
Application of porous ceramics for the attachment of load bearing internal orthopedic applications
Klawitter, J. J., & Hulbert, S. F. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050613 · Cited by 634
Biomaterials : an interfacial approach
Hench, L. L., & Ethridge, E. C. (1982) · Academic Press eBooks · Cited by 487
Collagen: Molecular Diversity in the Body's Protein Scaffold
Eyre, D. R. (1980) · Science · doi:10.1126/science.7355290 · Cited by 451
The intracellular degradation of poly(ε‐caprolactone)
Woodward, S. C., Brewer, P. S., Moatamed, F., Schindler, A., & Pitt, C. G. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190408 · Cited by 380
Fundamental aspects of biocompatibility
Williams, D. F. (1981) · CRC Press eBooks · Cited by 301
Biodegradation of and tissue reaction to 50:50 poly(DL‐lactide‐co‐glycolide) microcapsules
Visscher, G. E., Robison, R. L., Maulding, H. V., Fong, J. W., Pearson, J. E., & Argentieri, G. J. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190315 · Cited by 221
Clark, A. E., Hench, L. L., & Paschall, H. A. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100202 · Cited by 212
Research works printed but not linked: 12
- Jarcho M., 1977, Tissue cellular, and subcellular events at a bone ceramic hydroxyapatite interface, J. Bioeng., 1, 79
- Osborn J. F., 1980, Dental Implants, 111
- de Wijn J. R., 1981, Biocompatibility of Clinical Implant Materials, II, 99
- Chambers T. J., 1981, Fundamental Aspects of Biocompatibility I, 145
- Rae T., 1981, Fundamental Aspects of Biocompatibility I, 159
- Daems W. Th., 1980, The Reticuloendothelial System I, A Comprehensive Treatise, 57
- Kopecek J., 1983, Prog. Polym. Sci., 1
- J. G. F.Bots “Polyethers as biomaterials ” Thesis Technical University of Twente Enschede The Netherlands 1988.
- K. B.Stokes A. W.Frazer andE. A.Carter “The biostability of various polyetherurethanes under stress ” Prep. 42nd Annu. Tech. Conf. Soc. Plast. Eng. 30 Washington D.C. 1073(1984).
- Griss P., 1980, Mechanical Properties of Biomaterials, 217
- Williams D. F., 1978, Implants in Surgery, 203
- Hench L. L., 1981, Fundamental Aspects of Biocompatibility, 67
Cited by
Modification of polysiloxane polymers for biomedical applications: a review
Abbasi, F., Mirzadeh, H., & Katbab, A. (2001) · Polymer International · doi:10.1002/pi.783 · Cited by 500
Shape-memory polymers as a technology platform for biomedical applications
Lendlein, A., Behl, M., Hiebl, B., & Wischke, C. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.8 · Cited by 469
Gomes, P. S., & Fernandes, M. H. (2011) · Laboratory Animals · doi:10.1258/la.2010.010085 · Cited by 291
The ultrastructure of the bone‐hydroxyapatite interface in vitro
de Bruijn, J. D., Klein, C. P. A. T., de Groot, K., & van Blitterswijk, C. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820261008 · Cited by 134
Histological evaluation of a biodegradable polyactive®/ hydroxyapatite membrane
Jansen, J. A., de Ruijter, J. E., Janssen, P. T. M., & Paquay, Y. C. G. J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)94142-8 · Cited by 81
Interface reactions to PEO/PBT copolymers (polyactive®)after implantation in cortical bone
Radder, A. M., Leenders, H., & van Blitterswijk, C. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280202 · Cited by 74
Bakker, D., van Blitterswijk, C. A., Hesseling, S. C., Koerten, H. K., Kuijpers, W., & Grote, J. J. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240407 · Cited by 74
Self-citationGhassemifar, R., Redmond, S., Zainuddin, & Chirila, T. V. (2010) · Journal of Biomaterials Applications · doi:10.1177/0885328209104289 · Cited by 65
Evaluation of Two Biodegradable Polymeric Systems as Substrates for Bone Tissue Engineering
Mendes, S. C., Bezemer, J., Claase, M. B., Grijpma, D. W., Bellia, G., Degli-Innocenti, F., Reis, R. L., de Groot, K., van Blitterswijk, C. A., & de Bruijn, J. D. (2003) · Tissue Engineering · doi:10.1089/10763270360697003 · Cited by 66
FEMORAL CANAL OCCLUSION IN TOTAL HIP REPLACEMENT USING A RESORBABLE AND FLEXIBLE CEMENT RESTRICTOR
Bulstra, S. K., Geesink, R. G. T., Bakker, D., Bulstra, T. H., Bouwmeester, S. J. M., & van der Linden, A. J. (1996) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.78b6.0780892 · Cited by 65
Self-citationCompositional dependence of bioactivity of glasses in the system Na2O-K2O-MgO-CaO-B2O3-P2O5-SiO2
Brink, M., Turunen, T., Happonen, R.-P., & Yli-Urpo, A. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199710)37:1<114::aid-jbm14>3.0.co;2-g · Cited by 287
Bulk and surface modification of silicone rubber for biomedical applications
Abbasi, F., Mirzadeh, H., & Katbab, A. A. (2002) · Polymer International · doi:10.1002/pi.1069 · Cited by 53
Reactions of cells at implant surfaces
van Blitterswijk, C. A., Bakker, D., Hesseling, S. C., & Koerten, H. K. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90198-j · Cited by 52
Self-citationUpdates on polyurethane and its multifunctional applications in biomedical engineering
Miri, Z., Farè, S., Ma, Q., & Haugen, H. J. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acef84 · Cited by 52
Shi, B., Li, Y. R., Xu, J., Zou, J., Zhou, Z., Jia, Q., Hongxin, C., Jiang, H. B., & Liang, J. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e24348 · Cited by 58
“Moreover, ZrO 2 is not carcinogenic in vitro and does not cause chromosomal aberrations in cells [117,118].”
BackgroundFundamentals of Glucose Sensors
Fischer, U. (1991) · Diabetic Medicine · doi:10.1111/j.1464-5491.1991.tb01603.x · Cited by 45
Danino, M. A., Rocher, F., Blanchet‐Bardon, C., Revol, M. P., & Servant, J. M. (2001) · Annales de Chirurgie Plastique Esthétique · doi:10.1016/s0294-1260(01)80005-4 · Cited by 39
In Vivo Wound Healing Response to a Modified Degradable Fibrin Scaffold
Pandit, A. S., Feldman, D. S., & Caulfield, J. (1998) · Journal of Biomaterials Applications · doi:10.1177/088532829801200303 · Cited by 41
Kon, E., Muraglia, A., Corsi, A., Bianco, P., Marcacci, M., Martin, I., Boyde, A., Ruspantini, I., Chistolini, P., Rocca, M., et al. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(20000305)49:3<328::aid-jbm5>3.0.co;2-q · Cited by 721
Xi, T., Sato, M., Nakamura, A., Kawasaki, Y., Umemura, T., Tsuda, M., & Kurokawa, Y. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280411 · Cited by 33
Interfacial behavior of PEO/PBT copolymers (polyactive®) in a calvarial system: An in vitro study
Radder, A. M., Davies, J. E., Leenders, H., & van Blitterswijk, C. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280218 · Cited by 34
Fray, M. E., Bartkowiak, A., Prowans, P., & Słonecki, J. (2000) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008936114611 · Cited by 29
Polyactive® as a bone-filler in a beagle dog model
Meijer, G. J., van Dooren, A., Gallard, M. L., Dalmeijer, R. A. J., de Putter, C., Koole, R., & van Blitterswijk, C. (1996) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0901-5027(96)80033-6 · Cited by 31
MEIJER, G. J., Cune, M. S., DOOREN, M. V., de Putter, C., & van Blitterswijk, C. (1997) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1997.tb00300.x · Cited by 32
Roeßler, M., Wilke, A., GRISS, P., & Kienapfel, H. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(2000)53:2<131::aid-jbm1>3.0.co;2-i · Cited by 24
Overview of Biomedical Materials
Helmus, M. N. (1991) · MRS Bulletin · doi:10.1557/s0883769400056025 · Cited by 22
Implantate in der Mittelohrchirurgie
Geyer, G. (1992) · Springer eBooks · doi:10.1007/978-3-642-84669-4_11 · Cited by 20
Applications of Thermoplastic Elastomers
Drobny, J. G. (2007) · Elsevier eBooks · doi:10.1016/b978-081551549-4.50016-5 · Cited by 18
Flexible (Polyactive®) versus rigid (hydroxyapatite) dental implants
Meijer, G. J., Heethaar, J., Cune, M. S., de Putter, C., & van Blitterswijk, C. (1997) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0901-5027(05)80836-7 · Cited by 19
Bakker, D., van Blitterswijk, C., Hesseling, S. C., Daems, W., Kuijpers, W., & Grote, J. J. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240604 · Cited by 17
Self-citationUltrasonic implantation of calcium metasilicate glass particles into PMMA
Tsuru, K., Hayakawa, S., Ohtsuki, C., & Osaka, A. (1998) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008875502451 · Cited by 17
Applying a calcium phosphate layer on PEO/PBT copolymers affects bone formation in vivo
Gaillard, M. L., Brink, J. V. D., van Blitterswijk, C., & Luklinska, Z. B. (1994) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00058977 · Cited by 16
Long-term Evaluation of Porous PEGT/PBT Implants for Soft Tissue Augmentation
Lamme, E. N., Druecke, D., Pieper, J., May, P. S., Kaim, P., Jacobsen, F., Steinau, H., & Steinstraesser, L. (2007) · Journal of Biomaterials Applications · doi:10.1177/0885328206075552 · Cited by 13
Antigenicity of Polyester (Dacron) Vascular Prostheses in an Animal Model
Zippel, R., Wilhelm, L., Marusch, F., Koch, A., Urban, G., & Schlosser, M. (2001) · European Journal of Vascular and Endovascular Surgery · doi:10.1053/ejvs.2000.1298 · Cited by 13
Observations of the bone activity adjacent to unloaded dental implants coated with Polyactive® or HA
MEIJER, G. J., Radder, A. M., Dalmeijer, R. A. J., de Putter, C., & van Blitterswijk, C. (1995) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1995.tb01560.x · Cited by 13
Applications of Thermoplastic Elastomers
Drobny, J. G. (2014) · Elsevier eBooks · doi:10.1016/b978-0-323-22136-8.00015-6 · Cited by 9
MEIJER, G. J., Dalmeijer, R. A. J., de Putter, C., & van Blitterswijk, C. (1997) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1997.tb00301.x · Cited by 9
van Blitterswijk, C., de Wijn, J. R., Leenders, H., Brink, J., Hesseling, S. C., & Bakker, D. (1993) · Digital Commons - USU (Utah State University) · Cited by 7
Self-citationBiocompatibility of shape-memory polymers for biomedical applications
Mbeh, D. A., & do Nascimento, R. O. (2015) · Elsevier eBooks · doi:10.1016/b978-0-85709-698-2.00005-2 · Cited by 8
Gaillard, M. L., & van Blitterswijk, C. (1994) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00120359 · Cited by 6
de Bruijn, J. D., Klein, C. P. A. T., Terpstra, R. A., de Groot, K., & van Blitterswijk, C. (1991) · Springer eBooks · doi:10.1007/978-94-011-3852-9_45 · Cited by 5
Polyactive: A Bone-Bonding Polymer
van Blitterswijk, C., Grote, J. J., Hesseling, S. C., & Bakker, D. (1991) · Springer eBooks · doi:10.1007/978-94-011-3852-9_1 · Cited by 5
Self-citationHiebl, B., Kratz, K., Fuhrmann, R., Jung, F., Lendlein, A., & Franke, R.-P. (2009) · MRS Proceedings · doi:10.1557/proc-1190-nn06-05 · Cited by 3
Boss, J. H., Shajrawi, I., Soudry, M., Anullah, J., Solomon, H., & MENDES, D. G. (1994) · Clinical Materials · doi:10.1016/0267-6605(94)90010-8 · Cited by 3
The Chemical Processing of Silicates for Biological Applications - A Review
Hench, L. L., & Wilson, J. (1990) · MRS Proceedings · doi:10.1557/proc-180-1061 · Cited by 3
Biological evaluation of biomaterials for bone tissue regeneration
Ps, G. (2011) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/mf5d-dc29 · Cited by 2
Transmission Electron Microscopy of Tissue-Polymer Constructs
Hatton, P. V. (2003) · Humana Press eBooks · doi:10.1385/1-59259-428-x:197
Metadata
- Authors
- Bakker, D., van Blitterswijk, C. A., Hesseling, S. C., Daems, W. T., & Grote, J. J.
- Affiliations
- Leiden University Medical Center (NL)
- Leiden University (NL)
- ORCID
- Daems, W. Th.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1990-03
- Volume
- 24
- Issue
- 3
- Pages
- 277-293
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2074433667
- Cited by
- 49
- References
- 46
- Citations by year
- 2024: 1 · 2023: 1 · 2015: 1 · 2014: 1
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Keywords
- elastomers, polypropylene glycol, implant degradation, fibrous tissue encapsulation
- MeSH terms
- Animals, Biocompatible Materials, Male, Materials Testing, Microscopy, Electron, Rats, Inbred Strains, Rubber, Tympanic Membrane, Prostheses and Implants, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.