The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Ca, P‐rich layer formed on high‐strength bioactive glass‐ceramic A‐W
Abstract
Glass‐ceramic A‐W, containing crystalline apatite and wollastonite in a MgOCaOSiO 2 glassy matrix shows high bioactivity as well as high mechanical strength, but other ceramics containing the same kinds of crystalline phases in different glassy matrices do not show the same bioactivity. In order to investigate the bone‐bonding mechanism of this type of glass‐ceramic, surface structural changes of the glass‐ceramics after exposure to simulated body fluid were analyzed with various techniques. A solution with ion concentrations which are almost equal to those of the human blood plasma was used as the simulated body fluid, instead of Tris‐buffer solution hitherto used. For analyzing the surface structural changes, thin‐film x‐ray diffraction was used in addition to conventional techniques. It was found that a bioactive glass‐ceramic forms a Ca, P‐rich layer on its surface in the fluid but nonbioactive ones do not, and that the Ca, P‐rich layer consists of carbonate‐containing hydroxyapatite of small crystallites and/or defective structure. These findings were common to those of Bioglass‐type glasses. So, we conclude that the essential condition for glass and glass‐ceramic to bond to bone is the formation of the surface apatite layer in the body environment but it is not essential to contain apatite within the material. Bioactivity of glass and glass‐ceramic can be evaluated in vitro by examining the formation of the surface apatite layer in the simulated body fluid described above.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solutions able to reproduce in vivo surface‐structure changes in bioactive glass‐ceramic A‐W3
Kokubo, T., Kushitani, H., Sakka, S., Kitsugi, T., & Yamamuro, T. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240607 · Cited by 3,836
Self-citationChemical anatomy, physiology and pathology of extracellular fluid
Gamble, J. L. (1954) · University Microfilms International eBooks · Cited by 579
Tissue, cellular and subcellular events at a bone-ceramic hydroxylapatite interface.
Jarcho, M., Kay, J. F., Gumaer, K. I., Doremus, R. H., & Drobeck, H. P. (1977) · PubMed · Cited by 499
A new glass‐ceramic for bone replacement: Evaluation of its bonding to bone tissue
Nakamura, T., Yamamuro, T., Higashi, S., Kokubo, T., & Itoo, S. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190608 · Cited by 441
Self-citationApatite- and Wollastonite-Containg Glass-Ceramics for Prosthetic Application
Kokubo, T., Shigematsu, M., Nagashima, Y., Tashiro, M., Nakamura, T., Yamamuro, T., & Higashi, S. (1982) · Bulletin of the Institute for Chemical Research, Kyoto University · Cited by 430
Self-citationFormation of a high-strength bioactive glass-ceramic in the system MgO-CaO-SiO2-P2O5
Kokubo, T., Ito, S., Sakka, S., & Yamamuro, T. (1986) · Journal of Materials Science · doi:10.1007/bf01145520 · Cited by 351
Self-citationFundamental aspects of biocompatibility
Williams, D. F. (1981) · CRC Press eBooks · Cited by 301
Compositional dependence of the formation of calcium phosphate films on bioglass
Ogino, M., Ohuchi, F. S., & Hench, L. L. (1980) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820140107 · Cited by 281
Mechanical properties of a new type of apatite-containing glass-ceramic for prosthetic application
Kokubo, T., Ito, S., Shigematsu, M., Sakka, S., & Yamamuro, T. (1985) · Journal of Materials Science · doi:10.1007/bf01112282 · Cited by 270
Self-citationDirect electron microscopy studies of the bone—hydroxylapatite interface
Tracy, B. M., & Doremus, R. H. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180702 · Cited by 259
The interface of various glasses and glass ceramics with a bony implantation bed
Gross, U., & Strunz, V. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190308 · Cited by 223
Bone bonding behavior of three kinds of apatite containing glass ceramics
Kitsugi, T., Yamamuro, T., Nakamura, T., Higashi, S., Kakutani, Y., Hyakuna, K., Ito, S., Kokubo, T., Takagi, M., & Shibuya, T. (1986) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820200906 · Cited by 178
Self-citationKitsugi, T., Nakamura, T., Yamamura, T., Kokubu, T., Shibuya, T., & Takagi, M. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820211008 · Cited by 157
Self-citationProgress in artificial organs-1983
渥美, 和., Maekawa, M., & 太田, 和. (1984) · Cited by 152
Biocompatibility of orthopedic implants
Williams, D. F. (1982) · CRC Press eBooks · Cited by 150
Fatigue and life-time of bioactive glass-ceramic A-W containing apatite and wollastonite
Kokubo, T., Ito, S., Shigematsu, M., Sanka, S., & Yamamuro, T. (1987) · Journal of Materials Science · doi:10.1007/bf01133359 · Cited by 145
Self-citationThe ultrastructure of the interface between a glass ceramic and bone
Gross, U., Brandes, J., Strunz, V., Bab, I., & Sela, J. (1981) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820150302 · Cited by 128
Formation of calcium phosphate films on silicate glasses
Ogino, M., & Hench, L. L. (1980) · Journal of Non-Crystalline Solids · doi:10.1016/0022-3093(80)90514-1 · Cited by 124
Difference of bond bonding behavior among surface active glasses and sintered apatite
Fujiu, T., & Ogino, M. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180714 · Cited by 115
Development of machineable bioactive glass ceramics for medical uses
Vogel, W., Höland, W., Naumann, K., & Gummel, J. (1986) · Journal of Non-Crystalline Solids · doi:10.1016/0022-3093(86)90377-7 · Cited by 114
Kitsugi, T., Yamamuro, T., Nakamura, T., Kakutani, Y., Hayashi, T., Ito, S., Kokubo, T., Takagi, M., & Shibuya, T. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210407 · Cited by 40
Self-citationAspects of the Molecular Structure of Bone
Engström, A. (1972) · Elsevier eBooks · doi:10.1016/b978-0-12-119201-3.50014-7 · Cited by 36
Cited by
How useful is SBF in predicting in vivo bone bioactivity?
Kokubo, T., & Takadama, H. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.017 · Cited by 9,576
Self-citationSolutions able to reproduce in vivo surface‐structure changes in bioactive glass‐ceramic A‐W3
Kokubo, T., Kushitani, H., Sakka, S., Kitsugi, T., & Yamamuro, T. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240607 · Cited by 3,836
Self-citationSurface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487
Novel bioactive materials with different mechanical properties
Kokubo, T., Kim, H.-M., & Kawashita, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00044-9 · Cited by 1,914
Self-citationBioactive glass ceramics: properties and applications
Kokubo, T. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90194-f · Cited by 1,202
Self-citation
Metadata
- Authors
- Kokubo, T., Ito, S., Huang, Z. T., Hayashi, T., Sakka, S., Kitsugi, T., & Yamamuro, T.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1990-03
- Volume
- 24
- Issue
- 3
- Pages
- 331-343
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2150628505
- Cited by
- 859
- References
- 22
- FWCI
- 15.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.