CoChat

Cellular interactions with biomaterials: In vivo cracking of pre‐stressed pellethane 2363‐80A

Zhao, Q., Agger, M. P., Fitzpatrick, M., Anderson, J. M., Hiltner, A., Stokes, K., Urbanski, P. · 1990 · Journal of Biomedical Materials Research
Cited by 145

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The phenomenon of stress cracking of Pellethane 2363‐80A (PEU) was investigated using the cage implant system. A cytotoxic polyvinylchloride (PVC) and a silicone rubber containing an anti‐inflammatory steroid were used to create inflammatory environments in which the biostability of the pre‐stressed PEU was tested. These coimplants provided alternative in vivo environments to study in vivo polymer interactions. The inflammatory responses to the implanted cages were monitored by analyzing the exudates aspirated from the cages at different implantation times over 21 days. The pre‐stressed PEU specimens were retrieved after 5, 10, and 15 weeks postimplantation and examined by optical microscopy (OM) and scanning electron microscopy (SEM). The results support the conclusion that in vivo cracking of stressed (strained) Pellethane 80A is related to cell–polymer interactions. Severe cracking or rupture of the implanted PEU specimens was observed as early as 5 weeks postimplantation. Molecular chain degradation of the implanted specimens was evident from molecular weight measurements. Neither surface cracking nor degradation of macromolecules was found on the pre‐stressed PEU specimens with the added cytotoxic PVC implanted over 15 weeks. No cracking was observed on the pre‐stressed specimens in the presence of steroid silicone rubber, even after 10 weeks implantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820240508

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 145

Metadata

Authors
Zhao, Q., Agger, M. P., Fitzpatrick, M., Anderson, J. M., Hiltner, A., Stokes, K., & Urbanski, P.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1990-05
Volume
24
Issue
5
Pages
621-637
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W1974705988
Cited by
145
References
3
FWCI
7.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cellular interactions with biomaterials: In vivo cracking of pre‐stressed pellethane 2363‐80A. https://app.cochat.ai/papers/10.1002/jbm.820240508
The paper
Zhao, Q., Agger, M. P., Fitzpatrick, M., Anderson, J. M., Hiltner, A., Stokes, K., & Urbanski, P. (1990). Cellular interactions with biomaterials: In vivo cracking of pre‐stressed pellethane 2363‐80A. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820240508

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.