The DOI matches its Crossref record.
Inflammatory Responses to Biomaterials
Abstract
Implanted biomedical devices are of increasing importance in modern medical care. However, surprisingly little is known of the factors that determine biocompatibility of the materials used in these devices. These materials, although generally inert and non-toxic, can mediate a variety of adverse reactions, including inflammation, fibrosis, coagulation, and infection. This brief review focuses on the inflammatory responses (including fibrosis) that commonly occur around implanted biomaterials. Host proteins that spontaneously associate with implant surfaces are important determinants of the acute inflammatory response. In this regard, adsorbed fibrinogen appears particularly pro-inflammatory. Chronic inflammatory processes, in many cases in response to fragments of implanted biomaterials, may cause implant failure. In the case of silicone-filled mammary prostheses, the extravasation of silicone gel has been held responsible for a number of complications, including silicone granuloma, synovitis, connective-tissue disease, and lymphadenopathy. In some instances, material-mediated inflammatory responses may even cause degradation of the material itself (via oxidative products released by implant-associated inflammatory cells). Overall, there is insufficient knowledge of the determinants and mechanisms of host: implant responses. A clear understanding of tissue:biomaterial interactions will be required both to explain the pathogenesis of many implant-mediated complications and to aid in the development of more biocompatible materials for implantable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The application of hyaluronic acid in bone regeneration
Zhai, P., Peng, X., Li, B., Liu, Y., Sun, H., & Li, X. (2020) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2019.10.169 · Cited by 438
Targeting dendritic cells with biomaterials: developing the next generation of vaccines
Reddy, S. T., Swartz, M. A., & Hubbell, J. A. (2006) · Trends in Immunology · doi:10.1016/j.it.2006.10.005 · Cited by 406
Adverse Reactions to Injectable Soft Tissue Permanent Fillers
Christensen, L., Breiting, V., Janssen, M., Vuust, J., & Hogdall, E. (2005) · Aesthetic Plastic Surgery · doi:10.1007/s00266-004-0113-6 · Cited by 326
Kyriakides, T. R., Foster, M. J., Keeney, G. E., Tsai, A., Giachelli, C. M., Clark-Lewis, I., Rollins, B. J., & Bornstein, P. (2004) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)63265-8 · Cited by 226
Zdolsek, J., Eaton, J. W., & Tang, L. (2007) · Journal of Translational Medicine · doi:10.1186/1479-5876-5-31 · Cited by 154
Self-citation
Metadata
- Authors
- Tang, L., & Eaton, J. W.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-04-01
- Volume
- 103
- Issue
- 4
- Pages
- 466-471
- ISSN
- 0002-9173 (ISSN-L)
- 1943-7722
- OpenAlex
- W2229049611
- Cited by
- 481
- References
- 0
- FWCI
- 10.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inflammatory Responses to Biomaterials. https://app.cochat.ai/papers/10.1093/ajcp/103.4.466
- The paper
- Tang, L., & Eaton, J. W. (1995). Inflammatory Responses to Biomaterials. American Journal of Clinical Pathology. https://doi.org/10.1093/ajcp/103.4.466
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.