Evaluation of polyphosphates and polyphosphonates as degradable biomaterials
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A series of polymers, bisphenol A‐based poly(phosphoesters), were evaluated as degradable biomaterials. Degradation was observed for the four polymers studied under both in vitro and in vivo conditions. The rate of degradation was affected by polymer side‐chain structure and correlated with the swelling behavior. The ethyl side‐chain polymers absorbed more water than their phenyl counterparts. Among the sterilization methods, UV irradiation followed by antibiotic treatment was the most suitable, as steam autoclave and ethylene oxide treatments altered the properties of several of the poly(phosphoesters). Tissue response to the poly(phosphoesters) in rabbits was characterized by minor encapsulation and slight or no lymphocyte, giant cell, or macrophage activity. No evidence of edema or necrosis was found. The elastic moduli of these materials varied from 488 MPa for poly(bisphenol A‐ethylphosphate) (BPA/EOP) to 627 MPa for the more rigid poly(bisphenol A‐phenylphosphonate) (BPA/PP). The ultimate strength, modulus, and energy to failure of BPA/PP were lower than those of similarly compression molded high‐molecular‐weight poly(L‐lactic acid) (PLLA).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue response to implanted polymers: The significance of sample shape
Matlaga, B. F., Yasenchak, L. P., & Salthouse, T. N. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100308 · Cited by 295
Cited by
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Current applications and future perspectives of artificial nerve conduits
Jiang, X., Lim, S. H., Mao, H.-Q., & Chew, S. Y. (2010) · Experimental Neurology · doi:10.1016/j.expneurol.2009.09.009 · Cited by 394
Sterilization techniques for biodegradable scaffolds in tissue engineering applications
Dai, Z., Ronholm, J., Tian, Y., Sethi, B., & Cao, X. (2016) · Journal of Tissue Engineering · doi:10.1177/2041731416648810 · Cited by 355
Polypeptide growth factors: targeted delivery systems
Nimni, M. E. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00050-1 · Cited by 260
Fabrication of Controlled Release Biodegradable Foams by Phase Separation
Lo, H., Ponticiello, M. S., & Leong, K. W. (1995) · Tissue Engineering · doi:10.1089/ten.1995.1.15 · Cited by 259
Self-citationPre-clinical in vivo evaluation of orthopaedic bioabsorbable devices
An, Y. H., Woolf, S. K., & Friedman, R. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00132-0 · Cited by 224
Recent progress in polyphosphoesters: From controlled synthesis to biomedical applications
Wang, Y., Yuan, Y., Du, J., Yang, X., & Wang, J. (2009) · Macromolecular Bioscience · doi:10.1002/mabi.200900253 · Cited by 203
Bauer, K. N., Tee, H. T., Velencoso, M. M., & Wurm, F. R. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.05.004 · Cited by 189
A new nerve guide conduit material composed of a biodegradable poly(phosphoester)
Wang, S. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00356-2 · Cited by 176
“In vitro study Since the phosphoester bond in a PPE backbone is cleaved by water, the more readily water penetrates, the greater the bond cleavage and the faster its degradation rate [13].”
Background
Metadata
- Authors
- Richards, M., Dahiyat, B. I., Arm, D. M., Brown, P. R., & Leong, K. W.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1991-09
- Volume
- 25
- Issue
- 9
- Pages
- 1151-1167
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1974571231
- Cited by
- 82
- References
- 1
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.