The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Protein adsorption from human plasma is reduced on phospholipid polymers
Abstract
Protein adsorption from human plasma was investigated on phospholipid polymers, poly (2‐methacryloyloxyethyl phos‐phorylcholine (MPC)‐co‐n‐butyl methacrylate (BMA)) or glass by radioim‐munoassay and immunogold labeling techniques. In the present studies the focus was to determine the composition and distribution of proteins at the surface of these materials after contact with human blood plasma. On all materials, protein adsorption was detected and included identification of albumin, IgG, fibrinogen, fibronectin, Hageman factor (factor XII), factor VIII/von Willebrand factor, high‐molecular‐weight kininogen (HMWK) and the complement protein C5. The amount of protein adsorbed decreased with an increase in MPC composition and appeared to adsorb to the surfaces in a uniform and evenly distributed manner. Therefore, we suggest that MPC moieties play an important role in suppression of protein adsorption. From these findings, it is concluded that the reduction of protein adsorption at the blood contacting surface of phospholipid polymers may result in the inhibition of thrombus formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Some statistical methods useful in circulation research.
Wallenstein, S., Zucker, C. L., & Fleiss, J. L. (1980) · Circulation Research · doi:10.1161/01.res.47.1.1 · Cited by 3,886
Preparation of Phospholipid Polylners and Their Properties as Polymer Hydrogel Membranes
Ishihara, K., Ueda, T., & Nakabayashi, N. (1990) · Polymer Journal · doi:10.1295/polymj.22.355 · Cited by 1,078
Self-citationProtein adsorption and materials biocompatibility: A tutorial review and suggested hypotheses
Andrade, J. D., & Hlady, V. (1986) · Advances in Polymer Science · doi:10.1007/3-540-16422-7_6 · Cited by 810
Interaction of high molecular weight kininogen, factor XII, and fibrinogen in plasma at interfaces
Vroman, L., Adams, A., Fischer, G., & Munoz, P. (1980) · Blood · doi:10.1182/blood.v55.1.156.156 · Cited by 781
Grinnell, F., & Feld, M. K. (1982) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)34609-x · Cited by 622
Identification of rapid changes at plasma–solid interfaces
Vroman, L., & Adams, A. L. (1969) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820030106 · Cited by 419
Reduced thrombogenicity of polymers having phospholipid polar groups
Ishihara, K., Aragaki, R., Ueda, T., Watenabe, A., & Nakabayashi, N. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240809 · Cited by 394
Self-citationBiomembrane surfaces as models for polymer design: the potential for haemocompatibility
Hayward, J. A., & Chapman, D. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90047-4 · Cited by 391
Patterns of Adsorption of Proteins From Human Plasma Onto Foreign Surfaces
Uniyal, S., & Brash, J. L. (1982) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1657186 · Cited by 165
Vroman, L. (1988) · Europe PMC (PubMed Central) · Cited by 122
Brash, J. L., & Uniyal, S. (1979) · Journal of Polymer Science Polymer Symposia · doi:10.1002/polc.5070660135 · Cited by 118
Sequential protein adsorption and thrombus deposition on polymeric biomaterials
Pitt, W. G., Park, K., & Cooper, S. L. (1986) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(86)90039-1 · Cited by 115
Interaction between phospholipids and biocompatible polymers containing a phosphorylcholine moiety
Kojima, M., Ishihara, K., Watanabe, A., & Nakabayashi, N. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90189-h · Cited by 115
Self-citationPlatelet adhesion to polymer surfaces.
Kim, S. W., Lee, R. G., Oster, H., Coleman, D. L., Andrade, J. D., Lentz, D. J., & Olsen, D. B. (1974) · PubMed · Cited by 115
Blood Compatible Materials and Devices
Nunes, B. (1991) · Journal of Clinical Engineering · doi:10.1097/00004669-199103000-00014 · Cited by 103
Morphologic characteristics of adsorbed human plasma proteins on vascular grafts and biomaterials
Pankowsky, D. A., Ziats, N. P., Topham, N. S., Ratnoff, O. D., & Anderson, J. M. (1990) · Journal of Vascular Surgery · doi:10.1016/0741-5214(90)90309-x · Cited by 100
Self-citationAdsorption of Hageman factor (factor XII) and other human plasma proteins to biomedical polymers.
Ziats, N. P., Pankowsky, D. A., Tierney, B., Ratnoff, O. D., & Jm, A. (1990) · PubMed · Cited by 100
Self-citationIdentification of plasma proteins adsorbed to hemodialyzers during clinical use
Mulzer, S. R., & Brash, J. L. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820231210 · Cited by 84
Cited by
Jiang, S., & Cao, Z. (2010) · Advanced Materials · doi:10.1002/adma.200901407 · Cited by 2,027
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Zwitterionic hydrogels implanted in mice resist the foreign-body reaction
Zhang, L., Cao, Z., Bai, T., Carr, L., Ella-Menye, J.-R., Irvin, C., Ratner, B. D., & Jiang, S. (2013) · Nature Biotechnology · doi:10.1038/nbt.2580 · Cited by 1,035
Synthesis and Solution Properties of Zwitterionic Polymers
Lowe, A. B., & McCormick, C. L. (2002) · Chemical Reviews · doi:10.1021/cr020371t · Cited by 917
Li, Q., Wen, C., Yang, J., Zhou, X., Zhu, Y., Zheng, J., Cheng, G., Bai, J., Xu, T., Ji, J., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00344 · Cited by 790
Metadata
- Authors
- Ishihara, K., Ziats, N. P., Tierney, B. P., Nakabayashi, N., & Anderson, J. M.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1991-11
- Volume
- 25
- Issue
- 11
- Pages
- 1397-1407
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2072280479
- Cited by
- 471
- References
- 18
- FWCI
- 7.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.