The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Protein adsorption from human plasma is reduced on phospholipid polymers
Abstract
Protein adsorption from human plasma was investigated on phospholipid polymers, poly (2‐methacryloyloxyethyl phos‐phorylcholine (MPC)‐co‐n‐butyl methacrylate (BMA)) or glass by radioim‐munoassay and immunogold labeling techniques. In the present studies the focus was to determine the composition and distribution of proteins at the surface of these materials after contact with human blood plasma. On all materials, protein adsorption was detected and included identification of albumin, IgG, fibrinogen, fibronectin, Hageman factor (factor XII), factor VIII/von Willebrand factor, high‐molecular‐weight kininogen (HMWK) and the complement protein C5. The amount of protein adsorbed decreased with an increase in MPC composition and appeared to adsorb to the surfaces in a uniform and evenly distributed manner. Therefore, we suggest that MPC moieties play an important role in suppression of protein adsorption. From these findings, it is concluded that the reduction of protein adsorption at the blood contacting surface of phospholipid polymers may result in the inhibition of thrombus formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Some statistical methods useful in circulation research.
Wallenstein, S., Zucker, C. L., & Fleiss, J. L. (1980) · Circulation Research · doi:10.1161/01.res.47.1.1 · Cited by 3,886
Preparation of Phospholipid Polylners and Their Properties as Polymer Hydrogel Membranes
Ishihara, K., Ueda, T., & Nakabayashi, N. (1990) · Polymer Journal · doi:10.1295/polymj.22.355 · Cited by 1,078
Self-citationProtein adsorption and materials biocompatibility: A tutorial review and suggested hypotheses
Andrade, J. D., & Hlady, V. (1986) · Advances in Polymer Science · doi:10.1007/3-540-16422-7_6 · Cited by 810
Interaction of high molecular weight kininogen, factor XII, and fibrinogen in plasma at interfaces
Vroman, L., Adams, A., Fischer, G., & Munoz, P. (1980) · Blood · doi:10.1182/blood.v55.1.156.156 · Cited by 781
Grinnell, F., & Feld, M. K. (1982) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)34609-x · Cited by 622
Identification of rapid changes at plasma–solid interfaces
Vroman, L., & Adams, A. L. (1969) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820030106 · Cited by 419
Reduced thrombogenicity of polymers having phospholipid polar groups
Ishihara, K., Aragaki, R., Ueda, T., Watenabe, A., & Nakabayashi, N. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240809 · Cited by 394
Self-citationBiomembrane surfaces as models for polymer design: the potential for haemocompatibility
Hayward, J. A., & Chapman, D. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90047-4 · Cited by 391
Patterns of Adsorption of Proteins From Human Plasma Onto Foreign Surfaces
Uniyal, S., & Brash, J. L. (1982) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1657186 · Cited by 165
Vroman, L. (1988) · Europe PMC (PubMed Central) · Cited by 122
Cited by
Jiang, S., & Cao, Z. (2010) · Advanced Materials · doi:10.1002/adma.200901407 · Cited by 2,027
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Zwitterionic hydrogels implanted in mice resist the foreign-body reaction
Zhang, L., Cao, Z., Bai, T., Carr, L., Ella-Menye, J.-R., Irvin, C., Ratner, B. D., & Jiang, S. (2013) · Nature Biotechnology · doi:10.1038/nbt.2580 · Cited by 1,035
Synthesis and Solution Properties of Zwitterionic Polymers
Lowe, A. B., & McCormick, C. L. (2002) · Chemical Reviews · doi:10.1021/cr020371t · Cited by 917
Li, Q., Wen, C., Yang, J., Zhou, X., Zhu, Y., Zheng, J., Cheng, G., Bai, J., Xu, T., Ji, J., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00344 · Cited by 790
Zhang, Z., Chen, S., Chang, Y., & Jiang, S. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp057266i · Cited by 539
Phosphorylcholine-based polymers and their use in the prevention of biofouling
Lewis, A. L. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00152-6 · Cited by 497
Zhang, Z., Chen, S., & Jiang, S. (2006) · Biomacromolecules · doi:10.1021/bm060750m · Cited by 473
Hemocompatibility of human whole blood on polymers with a phospholipid polar group and its mechanism
Ishihara, K., Oshida, H., Endo, Y., Ueda, T., Watanabe, A., & Nakabayashi, N. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820261202 · Cited by 435
Self-citationSurface Design for Antibacterial Materials: From Fundamentals to Advanced Strategies
Li, W., Thian, E. S., Wang, M., Wang, Z., & Ren, L. (2021) · Advanced Science · doi:10.1002/advs.202100368 · Cited by 429
Protein Adsorption on Surfaces with Grafted Polymers
Szleifer, I. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78698-3 · Cited by 427
Optical grating coupler biosensors
Vörös, J., Ramsden, J. J., Csúcs, G., Szendrő, I., De Paul, S. M., Textor, M., & Spencer, N. D. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00103-5 · Cited by 406
(2020) · IntechOpen eBooks · doi:10.5772/intechopen.87879 · Cited by 384
Ueda, T., Oshida, H., Kurita, K., Ishihara, K., & Nakabayashi, N. (1992) · Polymer Journal · doi:10.1295/polymj.24.1259 · Cited by 363
Self-citationIwasaki, Y., & Ishihara, K. (2012) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/13/6/064101 · Cited by 346
Self-citationEffect of Chain Density on Inhibition of Protein Adsorption by Poly(ethylene glycol) Based Coatings
Malmsten, M., Emoto, K., & Van Alstine, J. M. (1998) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1998.5513 · Cited by 342
Phosphorylcholine-containing polymers for biomedical applications
Iwasaki, Y., & Ishihara, K. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2805-9 · Cited by 332
Self-citationCao, Z., & Jiang, S. (2012) · Nano Today · doi:10.1016/j.nantod.2012.08.001 · Cited by 329
Surface Engineering of Liposomes for Stealth Behavior
Nag, O., & Awasthi, V. (2013) · Pharmaceutics · doi:10.3390/pharmaceutics5040542 · Cited by 322
Nonfouling Behavior of Polycarboxybetaine-Grafted Surfaces: Structural and Environmental Effects
Zhang, Z., Vaisocherová, H., Cheng, G., Yang, W., Xue, H., & Jiang, S. (2008) · Biomacromolecules · doi:10.1021/bm800407r · Cited by 303
Blood compatible materials: state of the art
Liu, X., Yuan, L., Li, D., Tang, Z., Wang, Y., Chen, G., Chen, H., & Brash, J. L. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00881b · Cited by 288
Yang, W., Chen, S., Cheng, G., Vaisocherová, H., Xue, H., Li, W., Zhang, J., & Jiang, S. (2008) · Langmuir · doi:10.1021/la801487f · Cited by 258
3D spherical microtissues and microfluidic technology for multi-tissue experiments and analysis
Kim, J.-Y., Fluri, D. A., Marchan, R., Boonen, K., Mohanty, S., Singh, P., Hammad, S., Landuyt, B., Hengstler, J. G., Kelm, J. M., et al. (2015) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2015.01.003 · Cited by 126
Metadata
- Authors
- Ishihara, K., Ziats, N. P., Tierney, B. P., Nakabayashi, N., & Anderson, J. M.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1991-11
- Volume
- 25
- Issue
- 11
- Pages
- 1397-1407
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2072280479
- Cited by
- 471
- References
- 18
- FWCI
- 7.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.