Toxicity test of biodegradable polymers by implantation in rabbit cornea
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
To evaluate whether or not the corneal micropocket implantation is effective for determining the toxicity of polymeric materials, currently used biodegradable polymers such as poly(lactic acid) (PLA), poly(glycolic acid) (PGA), LA‐GA copolymers, and three kinds of poly(2‐cyanoacrylate)s (PCA) were implanted in a rabbit corneal pouch and the tissue responses were observed macroscopically and microscopically. It was found that PLA induced no vascularization, whereas a residual solvent and ethylene oxide gas remaining in the PLA matrix invoked vascularization. Vascularization clearly took place when PGA was implanted in the cornea, which became opaque, probably because of cellular infiltration. In the case of PCA implantation, severe inflammation as well as vascular invasion occurred in the initial stage. It is likely that these tissue reactions were caused by the leachables from the implanted materials, the extent being dependent on the leaching rate and the toxicity. It was concluded that the corneal micropocket assay is a good means to detect trace amounts of leachables from implanted materials without sacrificing the animals with the implanted materials. © 1992 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polymers for the sustained release of proteins and other macromolecules
LANGER, R., & FOLKMAN, J. (1976) · Nature · doi:10.1038/263797a0 · Cited by 1,182
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Cited by
Poly(lactic acid) modifications
Rasal, R. M., Janorkar, A. V., & Hirt, D. E. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.12.003 · Cited by 2,204
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Kuppermann, B. D. (2007) · Archives of Ophthalmology · doi:10.1001/archopht.125.3.309 · Cited by 429
Bourges, J.-L., Gautier, S. E., Delie, F., Bejjani, R. A., Jeanny, J.-C., Gurny, R., BenEzra, D., & Behar-Cohen, F. F. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1068 · Cited by 357
Recent advances in biodegradable polymers – Properties, applications and future prospects
Mukherjee, C., Varghese, D., Krishna, J. S., Boominathan, T., Rakeshkumar, R., Dineshkumar, S., Brahmananda Rao, C. V. S., & Sivaramakrishna, A. (2023) · European Polymer Journal · doi:10.1016/j.eurpolymj.2023.112068 · Cited by 321
Metadata
- Authors
- Kobayashi, H., Shiraki, K., & Ikada, Y.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1992-11
- Volume
- 26
- Issue
- 11
- Pages
- 1463-1476
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2054450566
- Cited by
- 87
- References
- 2
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.