The DOI matches its Crossref record.
A histological and histomorphometrical investigation of fluorapatite, magnesiumwhitlockite, and hydroxylapatite plasma‐sprayed coatings in goats
Abstract
Plasma‐sprayed ceramic coatings of fluorapatite (FA), magnesiumwhitlockite (MW), and hydroxylapatite (HA), and noncoated Ti‐6Al‐4V alloy (Ti) implants were evaluated histologically and histomorphometrically in a goat animal study. Cylindrical Ti‐6Al‐4V plugs were plasma‐spray‐coated with FA, MW, and HA. Noncoated, gritblasted Ti plugs served as controls. The plugs were implanted into the right femur and left humerus of 20 adults goats. The results were evaluated using descriptive histology and histomorphometry. The histomorphometry consisted of measurements of bone apposition and coating thickness. The results demonstrated that FA showed a high amount of bone apposition without signs of degradation or dissolution. MW showed considerable reduction in thickness and at 12 weeks an adverse tissue reaction. However, at 25 weeks the amount of bone apposition was significantly increased compared with the 12‐week implants. HA revealed considerable and progressive reduction in thickness and at 25 weeks a lower amount of bone apposition than FA and MW. At 12 weeks the Ti implants did reveal bone apposition, although frequently localized fibrous tissue was visible. At 25 weeks the Ti implants did not differ in bone apposition from the HA implants. Further studies are necessary on the effect of degradation or dissolution of HA on the compatibility with bone. © 1993 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ti based biomaterials, the ultimate choice for orthopaedic implants – A review
Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009) · Progress in Materials Science · doi:10.1016/j.pmatsci.2008.06.004 · Cited by 5,416
Material fundamentals and clinical performance of plasma‐sprayed hydroxyapatite coatings: A review
Sun, L., Berndt, C. C., Gross, K. A., & Kucuk, A. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1056 · Cited by 1,065
Implant Surface Roughness and Bone Healing: a Systematic Review
Shalabi, M. M., Gortemaker, A., Hof, M. A. V., Jansen, J. A., & Creugers, N. H. J. (2006) · Journal of Dental Research · doi:10.1177/154405910608500603 · Cited by 531
Self-citationSubstituted hydroxyapatite coatings of bone implants
Arcos, D., & Vallet-Regí, M. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02710f · Cited by 415
Calcium phosphate coatings for medical implants
de Groot, K., Wolke, J. G. C., & Jansen, J. A. (1998) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411981533917 · Cited by 400
Self-citationOrganic–Inorganic Surface Modifications for Titanium Implant Surfaces
de Jonge, L. T., Leeuwenburgh, S. C. G., Wolke, J. G. C., & Jansen, J. A. (2008) · Pharmaceutical Research · doi:10.1007/s11095-008-9617-0 · Cited by 361
Self-citationHydroxyapatite and Their Use As Coatings in Dental Implants: A Review
Ong, J. L., & Chan, D. C. N. (2000) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v28.i56.10 · Cited by 315
Advanced biomaterials for skeletal tissue regeneration: Instructive and smart functions
Barrère, F., Mahmood, T. A., de Groot, K., & van Blitterswijk, C. A. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.12.001 · Cited by 303
Self-citationCalcium orthophosphate deposits: Preparation, properties and biomedical applications
Dorozhkin, S. V. (2015) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.05.033 · Cited by 298
Barrère, F., van der Valk, C. M., Meijer, G., Dalmeijer, R. A. J., de Groot, K., & Layrolle, P. (2003) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.10057 · Cited by 274
Self-citationSerre, C. M., Papillard, M., Chavassieux, P., Voegel, J. C., & Boivin, G. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19981215)42:4<626::aid-jbm20>3.0.co;2-s · Cited by 252
An animal study on the bone behaviour of Ca–P-coated implants: influence of implant location
CAULIER, H., HAYAKAWA, T., NAERT, I., VAN DER WAERDEN, J. P. C. M., WOLKE, J. G. C., & JANSEN, J. A. (1997) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1018542630017 · Cited by 11
Self-citation
Metadata
- Authors
- Dhert, W. J. A., Klein, C. P. A. T., Jansen, J. A., van der Velde, E. A., Vriesde, R. C., Rozing, P. M., & de Groot, K.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1993-01
- Volume
- 27
- Issue
- 1
- Pages
- 127-138
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1979505150
- Cited by
- 179
- References
- 0
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.