Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 257

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Experimental determination of friction characteristics at the trabecular bone/porous‐coated metal interface in cementless implants

Shirazi‐Adl, A., Dammak, M., Paiement, G.·1993·Journal of Biomedical Materials Research

Abstract

An apparatus was developed to measure loaddisplacement friction properties at the cancellous bone/porous‐coated metal plate interface. Bone cubes were obtained from different proximal regions of four resurfaced cadaveric tibiae. Three different poroussurfaced metal plates (one fiber mesh and two bead) and a smooth‐surfaced metal plate were used. In the presence of a constant normal contact pressure (0.10, 0.15, or 0.25 MPa), a variable tangential load up to the maximum resistance of the interface was applied and both relative normal and tangential displacements were recorded. Repetitive and fatigue loadings were also considered. Measured results show that the interface friction curve is highly nonlinear, exhibiting large relative tangential displacements in the range of 50–400 μm before the maximum load is reached. Relative displacements in the normal direction remain below 10 μm. The maximum resistance in friction is independent of the bone excision site, type of porous‐surfaced metal plate, magnitude of normal load, placement of bone cubes on metal plates or vice versa, repetition of applied load, and conservation period of bone cubes in saline solution. The smoothsurfaced metal plate has significantly smaller friction resistance than porous‐coated ones. The fatigue loading of up to 4000 cycles at 1 Hz, in the presence of 0.25 MPa contact pressure, slightly decrease the interface friction coefficient. Finally, the initial secant stiffness of the interface at 75% of the maximum resistance load is found to be larger for the bone cubes from the lateral and medial regions and for the metal plate with smooth surface. © 1993 John Wiley & Sons, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820270205

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 257

Metadata

Authors
Shirazi‐Adl, A., Dammak, M., & Paiement, G.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1993-02
Volume
27
Issue
2
Pages
167-175
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2156063243
Cited by
257
References
4
FWCI
3.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental determination of friction characteristics at the trabecular bone/porous‐coated metal interface in cementless implants. https://app.cochat.ai/papers/10.1002/jbm.820270205
The paper
Shirazi‐Adl, A., Dammak, M., & Paiement, G. (1993). Experimental determination of friction characteristics at the trabecular bone/porous‐coated metal interface in cementless implants. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820270205

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.