Experimental determination of friction characteristics at the trabecular bone/porous‐coated metal interface in cementless implants
Abstract
An apparatus was developed to measure loaddisplacement friction properties at the cancellous bone/porous‐coated metal plate interface. Bone cubes were obtained from different proximal regions of four resurfaced cadaveric tibiae. Three different poroussurfaced metal plates (one fiber mesh and two bead) and a smooth‐surfaced metal plate were used. In the presence of a constant normal contact pressure (0.10, 0.15, or 0.25 MPa), a variable tangential load up to the maximum resistance of the interface was applied and both relative normal and tangential displacements were recorded. Repetitive and fatigue loadings were also considered. Measured results show that the interface friction curve is highly nonlinear, exhibiting large relative tangential displacements in the range of 50–400 μm before the maximum load is reached. Relative displacements in the normal direction remain below 10 μm. The maximum resistance in friction is independent of the bone excision site, type of porous‐surfaced metal plate, magnitude of normal load, placement of bone cubes on metal plates or vice versa, repetition of applied load, and conservation period of bone cubes in saline solution. The smoothsurfaced metal plate has significantly smaller friction resistance than porous‐coated ones. The fatigue loading of up to 4000 cycles at 1 Hz, in the presence of 0.25 MPa contact pressure, slightly decrease the interface friction coefficient. Finally, the initial secant stiffness of the interface at 75% of the maximum resistance load is found to be larger for the bone cubes from the lateral and medial regions and for the metal plate with smooth surface. © 1993 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone
BOBYN, J. D., PILLIAR, R. M., CAMERON, H. U., & WEATHERLY, G. C. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00045 · Cited by 832
Total Joint Arthroplasty of the Knee
Hungerford, D. S., & Krackow, K. A. (1985) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198501000-00004 · Cited by 306
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90097-0 · Cited by 292
Radiographic and Morphologic Studies of Load-Bearing Porous-Surfaced Structured Implants
Pilliar, R. M., Cameron, H. U., WELSH, R. P., & Binnington, A. G. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198105000-00037 · Cited by 129
Cited by
Rao, P. J., Pelletier, M. H., Walsh, W. R., & Mobbs, R. J. (2014) · Orthopaedic Surgery · doi:10.1111/os.12098 · Cited by 285
Biomechanical behaviours of the bone–implant interface: a review
Gao, X., Fraulob, M., & Haïat, G. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0259 · Cited by 263
Metadata
- Authors
- Shirazi‐Adl, A., Dammak, M., & Paiement, G.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1993-02
- Volume
- 27
- Issue
- 2
- Pages
- 167-175
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2156063243
- Cited by
- 257
- References
- 4
- FWCI
- 3.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental determination of friction characteristics at the trabecular bone/porous‐coated metal interface in cementless implants. https://app.cochat.ai/papers/10.1002/jbm.820270205
- The paper
- Shirazi‐Adl, A., Dammak, M., & Paiement, G. (1993). Experimental determination of friction characteristics at the trabecular bone/porous‐coated metal interface in cementless implants. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820270205
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.