CoChat

Contact activation of the plasma coagulation cascade. I. Procoagulant surface chemistry and energy

Vogler, Erwin A., Graper, Jane C., Harper, Garry R., Sugg, Harry W., Lander, Lorraine M., Brittain, William J. · 1995 · Journal of Biomedical Materials Research
Cited by 131

The DOI matches its Crossref record.

Abstract

Contact activation of the intrinsic pathway of porcine blood plasma coagulation is shown to be a steep exponential‐like function of procoagulant surface energy, with low activation observed for poorly water‐wettable surfaces and very high activation for fully water‐wettable surfaces. Test procoagulants studied were a system of oxidized polystyrene films with varying wettability (surface energy) and glass discs bearing close‐packed self‐assembled silane monolayers (SAMs) with well‐defined chemistry consisting of 12 different terminating chemical functionalities. A monotonic trend of increasing coagulation activation with increasing water wettability was observed for the oxidized polystyrene system whereas results with SAM procoagulants suggested a level of chemical specificity over and above the surface energy trend. In particular, it was noted that coagulation activation by SAMs terminated with CO 2 H was much higher than anticipated based on surface wettability whereas NH 3⊕‐terminated SAMs exhibited very low procoagulant activity. SAMs terminated in (CH 2)2(CF 2)7 CF 3 behaved as anticipated based on surface energy with very low procoagulant activity and did not exhibit special properties sometimes attributed to perfluorinated compounds. Quantitative ranking of the inherent coagulation activation properties of procoagulant surfaces was obtained by application of a straightforward phenomenological model expressed in a closed‐form mathematical equation relating coagulation time to procoagulant surface area. Fit of the model with a single adjustable parameter to experimental measurements of porcine platelet‐poor plasma coagulation time was very good, implying that assertions and simplifications of the model adequately simulated reality. Two important propositions of the model were that (1) the number of putative “activating sites” scaled linearly with procoagulant surface area, and (2) contact activation of the plasma coagulation cascade was catalytic in the sense that these activating sites were not consumed or “poisoned” by irreversible or slowly reversible protein adsorption during coagulation. An extension of the coagulation model proposed that procoagulant activation properties scale exponentially with the surface density of polar (acid‐base) sites, which, in turn, was related to procoagulant wettability. © 1995 John Wiley & Sons, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820290813

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Vogler, E. A., Graper, J. C., Harper, G. R., Sugg, H. W., Lander, L. M., & Brittain, W. J.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1995-08
Volume
29
Issue
8
Pages
1005-1016
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2002204070
Cited by
131
References
0
FWCI
3.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.