CoChat

Evaluation of poly(DTH carbonate), a tyrosine‐derived degradable polymer, for orthopedic applications

Ertel, Sylvie I., Kohn, Joachim, Zimmerman, Mark C., Parsons, J. Russell · 1995 · Journal of Biomedical Materials Research
Cited by 53

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The polymerization of desaminotyrosinetyrosylhexyl ester (DTH) with phosgene gives rise to poly(DTH carbonate), a new pseudopoly(amino acid). To evaluate the performance of this bioabsorbable material in orthopedic applications, the tissue responses elicited by compression‐molded pins of poly(DTH carbonate) and clinically used polydioxanone pins (PDS; Orthosorb®) were compared. The two types of pins were implanted in the paravertebral muscle and in the metaphyseal proximal tibia and distal femur of 10 White New Zealand Rabbits for 1, 2, 4, and 26 weeks. The tissue response was evaluated using histologic staining of softand hard‐tissue sections, fluorescent bone marker incorporation, and backscattered electron imaging. In soft tissue, both poly(DTH carbonate) and PDS elicited a mild inflammatory response resulting in encapsulation. During the disintegration phase, the PDS implants triggered a foreign body response involving the phagocytosis of polymeric debris by histiocytes and giant cells. No such response was observed for poly(DTH carbonate). In hard tissue, close bone apposition was observed throughout the 26‐week test period for poly(DTH carbonate) implants. At the 26‐week time point, the poly(DTH carbonate) implants exhibited surface erosion and were penetrated by new bone. In contrast, an intervening fibrous tissue layer was always present between the PDS pins and the bone. At 26 weeks, the PDS implants had partially resorbed and a foreign body response characterized by infiltration of inflammatory cells, and bone resorption was observed in several of the implantation sites. This study indicates that poly(DTH carbonate) and PDS exhibit fundamentally different interactions with hard tissue, and that poly(DTH carbonate) is a promising orthopedic implant material. © 1995 John Wiley & Sons, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820291105

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Ertel, S. I., Kohn, J., Zimmerman, M. C., & Parsons, J. R.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1995-11
Volume
29
Issue
11
Pages
1337-1348
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2091157716
Cited by
53
References
2
FWCI
2.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.