Preparation of a macroporous biodegradable polylactide implant for neuronal transplantation
The DOI matches its Crossref record.
Abstract
This article reports the production of a surgical implant meeting several specific requirements such as biocompatibility, biodegradability, macroporosity, and flexibility. Porosity was controlled by an original method consisting of the aggregation of calibrated poly‐D,L‐lactide microparticles. The size of the interstices between the aggregated microspheres was in a direct relationship to the microsphere diameter. A first approach was based on coating the microspheres with poly(vinyl alcohol) followed by chemically crosslinking the coating layers that were in mutual contact. This method was disregarded because of the acute cytotoxicity of glutaraldehyde used as the crosslinking agent, the absence of macroporosity, and the complete lack of flexibility. A physical technique of aggregation was then tested, which relied on the plasticization of poly‐D,L‐lactide microspheres with triethylcitrate to the point where microspheres strongly adhered to each other when they were in contact. This method has proved to be straightforward and definitely superior to the chemical approach, particularly with respect to cytotoxicity, control of macroporosity, and flexibility. A polymer support was thus successfully produced which was biodegradable, macroporous (interconnected pores of 10–100 μm in diameter), and flexible. This potential medical device is presently being used for neuronal transplantation in the central nervous system. © 1995 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Poly(lactic acid) modifications
Rasal, R. M., Janorkar, A. V., & Hirt, D. E. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.12.003 · Cited by 2,204
Chitosan and its derivatives for tissue engineering applications
Kim, I.-Y., Seo, S.-J., Moon, H.-S., Yoo, M.-K., Park, I.-Y., Kim, B.-C., & Cho, C.-S. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2007.07.009 · Cited by 1,433
Synthetic nano-scale fibrous extracellular matrix
Ma, P. X., & Zhang, R. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199907)46:1<60::aid-jbm7>3.0.co;2-h · Cited by 1,049
Taboas, J. M., Maddox, R. D., Krebsbach, P. H., & Hollister, S. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00276-4 · Cited by 691
Preparation of porous scaffolds by using freeze-extraction and freeze-gelation methods
Ho, M.-H., Kuo, P.-Y., Hsieh, H.-J., Hsien, T.-Y., Hou, L.-T., Lai, J.-Y., & Wang, D.-M. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00483-6 · Cited by 484
Ma, P. X., Zhang, R., Xiao, G., & Franceschi, R. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200102)54:2<284::aid-jbm16>3.0.co;2-w · Cited by 429
Reignier, J., & Huneault, M. A. (2006) · Polymer · doi:10.1016/j.polymer.2006.04.029 · Cited by 245
Toughness decrease of PLA‐PHBHHx blend films upon surface‐confined photopolymerization
Rasal, R. M., & Hirt, D. E. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32009 · Cited by 120
Assessment of the Biocompatibility of the PLLA-PLCL Scaffold Obtained by Electrospinning
Oyama, H. T. T., Cortella, L. R. X., Rosa, I. N. S., Filho, L. E. R., Hui, W. S., Cestari, I. N., & Cestari, I. A. (2015) · Procedia Engineering · doi:10.1016/j.proeng.2015.07.021 · Cited by 9
Metadata
- Authors
- Schugens, C., Grandfils, C., Jerome, R., Teyssie, P., Delree, P., Martin, D., Malgrange, B., & Moonen, G.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1995-11
- Volume
- 29
- Issue
- 11
- Pages
- 1349-1362
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2077740489
- Cited by
- 78
- References
- 0
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.