The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Effect of surface topology on the osseointegration of implant materials in trabecular bone
Abstract
The importance of surface topology and implant material composition on osseointegration in trabecular bone was investigated using three commercially used implant materials and surface‐texturing procedures which included blasting, high temperature acid etching, and hydroxyapatite (HA) coating. Surface roughness and spacing parameters were measured for each implant group with a laser interferometric profilometer. Cylindrical implants were press‐fit into trabecular bone sites in the knee of mature miniature pigs. After 12 weeks in situ, osseointegration was evaluated by (1) mechanical pushout tests to measure bone‐implant interface strength and (2) quantitative morphometric measurements of the percent implant surface covered by bone. We found that HA‐coated implants showed superior osseointegration in terms of both pushout failure load and surface coverage by bone measurements. An excellent correlation (r2 = .90) was found between the average roughness of the implant surface and pushout failure load. New methods for altering the local topologic and/or chemical state of the implant surface (i.e., by acid etching) may provide an important new avenue of research for improving the osseointegrative properties of orthopedic materials. © 1995 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The efficiency of systematic sampling in stereology and its prediction*
Gundersen, H. J. G., & Jensen, E. B. (1987) · Journal of Microscopy · doi:10.1111/j.1365-2818.1987.tb02837.x · Cited by 3,520
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719
Self-citationBrown, W. A. B. (1985) · FEBS Letters · doi:10.1016/0014-5793(85)81367-3 · Cited by 495
SCHMALZRIED, T. P., KWONG, L. M., JASTY, M., SEDLACEK, R. C., HAIRE, T. C., O'CONNOR, D. O., BRAGDON, C. R., KABO, J. M., MALCOLM, A. J., & HARRIS, W. H. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199201000-00009 · Cited by 443
A review of recent advances in stereology for quantifying neural structure
Mayhew, T. M. (1992) · Journal of Neurocytology · doi:10.1007/bf01191700 · Cited by 330
An evaluation of variables influencing implant fixation by direct bone apposition
Thomas, K. A., & Cook, S. D. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190802 · Cited by 313
Doyle, C. (1987) · Clinical Materials · doi:10.1016/0267-6605(87)90038-2 · Cited by 113
Analysis of organic and biological surfaces
Logsdon, D. F. (1985) · Microchemical Journal · doi:10.1016/0026-265x(85)90106-7 · Cited by 69
Cited by
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Understanding and controlling the bone–implant interface
Puleo, D. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00160-x · Cited by 1,342
Eliaz, N., & Metoki, N. (2017) · Materials · doi:10.3390/ma10040334 · Cited by 1,088
Advancing dental implant surface technology – From micron- to nanotopography
Mendonça, G., Mendonça, D. B. S., Aragão, F. J. L., & Cooper, L. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.012 · Cited by 990
Engineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Metadata
- Authors
- Wong, M., Eulenberger, J., Schenk, R., & Hunziker, E.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1995-12
- Volume
- 29
- Issue
- 12
- Pages
- 1567-1575
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2021381535
- Cited by
- 449
- References
- 8
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.