Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 216

The DOI matches its Crossref record.

Mediation of bone ingrowth in porous hydroxyapatite bone graft substitutes

Open access
Hing, Karin A., Best, Serena M., Tanner, K. Elizabeth, Bonfield, William, Revell, Peter A. · 2004 · Journal of Biomedical Materials Research Part A

Abstract

Previous investigations have shown that both the early biological response and the mechanical properties of a porous hydroxyapatite bone graft substitute are highly sensitive to its pore structure. The objective of this study was to evaluate whether the pore structure continued to influence bone integration in the medium to long term. Two screened batches of porous hydroxyapatite (PHA) designated as batch A and batch B, with porosities of ∼60 and 80%, respectively, were selected for this study and implanted for periods of 5, 13, and 26 weeks into the lower femur of New Zealand White rabbits. Histomorphometric analysis of the absolute volume of bone ingrowth within batch A and B implants from 5 to 26 weeks showed that the absolute volume of bone ingrowth was consistently lower in batch A (10–21%), compared to batch B implants (24–31%). However, when the volume of bone ingrowth was normalised for the available pore space, this difference was reduced (23–47% and 32–42% for batches A and B, respectively). These observations suggest that differences in the volume of bone ingrowth initially depended on pore interconnectivity rather than pore size, whereas the volume or morphology of the PHA influenced the volume and morphology of bone ingrowth at later time points. Compression testing showed that bone ingrowth had a strong reinforcing effect on PHA bone graft substitutes, and a strong correlation was identified between mechanical properties and the absolute volume of ingrowth for both batches A and B. Furthermore, at 13 and 26 weeks, there was no significant variation in the ultimate compressive strength of integrated batch A and B implants. This similarity in ultimate mechanical properties indicated that the absolute volume of ingrowth may be mediated by the PHA structure through its impact on the dynamics of the local biomechanical environment. The results of push‐out testing showed that fixation of PHA bone graft substitutes was independent of density within the range studied, with no significant difference in the interfacial shear stress between batches A and B at each time point throughout the study. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 68A: 187–200, 2004

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.10050

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hing, K. A., Best, S. M., Tanner, K. E., Bonfield, W., & Revell, P. A.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2003-12
Volume
68A
Issue
1
Pages
187-200
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2062019596
Cited by
216
References
0
FWCI
5.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.