In vitro assessment of bioactive coatings for neural implant applications
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Recent efforts in our laboratory have focused on developing methods for immobilizing bioactive peptides to low cell‐adhesive dextran monolayer coatings and promoting biospecific cell adhesion for biomaterial implant applications. In the current study, this dextran‐based bioactive coating technology was developed for silicon, polyimide, and gold, the base materials utilized to fabricate our prototype neural implants. Chemical composition of all modified surfaces was verified by X‐ray photoelectron spectroscopy (XPS). We observed that surface‐immobilized dextran supported very little cell adhesion in vitro (24‐h incubation with serum‐supplemented medium) on all base materials. Inactive nonadhesion‐promoting Gly‐Arg‐Ala‐Asp‐Ser‐Pro peptides immobilized on dextran‐coated materials promoted adhesion and spreading at low levels not significantly different from dextran‐coated substrates. Arg‐Gly‐Asp (RGD) peptide‐grafted surfaces were observed to promote substantial fibroblast and glial cell adhesion with minimal PC12 (neuronal cell) adhesion. In contrast, dextran‐coated materials with surface‐grafted laminin‐based, neurite‐promoting Ile‐Lys‐Val‐Ala‐Val (IKVAV) peptide promoted substantial neuron cell adhesion and minimal fibroblast and glial cell adhesion. It was concluded that neuron‐selective substrates are feasible using dextran‐based surface chemistry strategies. The chemical surface modifications could be utilized to establish a stable neural tissue–implant interface for long‐term performance of neural prosthetic devices. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 68A: 177–186, 2004
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060
Implantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Cited by
Li, N., Zhang, X., Song, Q., Su, R., Zhang, Q., Kong, T., Liu, L., Jin, G., Tang, M., & Cheng, G. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.08.065 · Cited by 428
Approaches to neural tissue engineering using scaffolds for drug delivery
Willerth, S. M., & Sakiyama-Elbert, S. E. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.014 · Cited by 392
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“(266) This work highlights the specificity of LN peptides for supporting neuronal attachment, and reinvigorated the use of LN-derived strategies for intracortical microelectrode applications.”
Nano-magnetic particles used in biomedicine: Core and coating materials
Karimi, Z., Karimi, L., & Shokrollahi, H. (2013) · Materials Science and Engineering: C · doi:10.1016/j.msec.2013.01.045 · Cited by 276
Bairagi, D., & Mandal, S. (2022) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.09.005 · Cited by 272
Metadata
- Authors
- Massia, S. P., Holecko, M. M., & Ehteshami, G. R.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-12
- Volume
- 68A
- Issue
- 1
- Pages
- 177-186
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2079120232
- Cited by
- 108
- References
- 3
- FWCI
- 1.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.