CoChat

Use of vascular endothelial cell growth factor gene transfer to enhance implantable sensor function in vivo

Klueh, U., Dorsky, D. I., Kreutzer, D. L. · 2003 · Journal of Biomedical Materials Research Part A
Cited by 26

The DOI matches its Crossref record.

Abstract

In the current study, we developed and validated a simple, rapid and safe in vivo model to test gene transfer and sensor function in vivo. Using the model, we tested the specific hypothesis that in vivo gene transfer of angiogenic factors at sites of biosensor implantation would induce neovascularization surrounding the sensor and thereby enhance biosensor function in vivo. As the in vivo site for testing of our gene transfer cell and biosensor function systems, the developing chorioallantoic membrane (CAM) of the embryo was utilized. Vascular endothelial cell growth factor (VEGF) was used as a prototype for angiogenic factor gene transfer. A helper‐independent retroviral vector derived from Rous sarcoma virus (RSV), designated RCAS, was used for gene transfer of the murine VEGF (mVEGF) gene (mVEGF:RCAS) into the DF‐1 chicken cell line (designated mVEGF:DF‐1). Initially, the ability of VEGF:DF‐1 cells to produce VEGF and RCAS viral vectors containing the mVEGF gene (mVEGF:RCAS) was validated in vitro and in vivo, as was the ability of the mVEGF:DF‐1 cells to induce neovascularization in the ex ova CAM model. Using the system, we determined the ability of mVEGF:DF‐1 cells to enhance acetaminophen senor function in vivo, by inducing neovascularization at sites of sensor implantation in the ex ova CAM model. For these studies, acetaminophen sensors were placed on 8‐day‐old ex ova CAMs, followed by addition of media or cells (mVEGF:DF‐1 cells or GFP:DF‐1 cells) at the sites of biosensor implantation on the CAM. At 4 to 10 days after sensor placement, the biosensor function was determined by measuring sensor response to an intravenous injection of acetaminophen. Sensors implanted on CAMs with buffer or control cells (GFP:DF‐1 cells) displayed no induced neovascularization around the sensor and had minimal/baseline sensor responses to intravenous acetaminophen injection (media, 133.33 ± 27.64 nA; GFP:DF‐1, 187.50 ± 55.43 nA). Alternatively, the sensors implanted with mVEGF:DF‐1 cells displayed massive neovascularization and equally massive sensor response to intravenous injection of acetaminophen (VEGF:DF‐1, 1387.50 ± 276.42 nA). These data clearly demonstrate that enhancing vessel density (i.e., neovascularization) around an implanted sensor dramatically enhances sensor function in vivo. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 1072–1086, 2003

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.20041

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 26

Metadata

Authors
Klueh, U., Dorsky, D. I., & Kreutzer, D. L.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2003-10-27
Volume
67A
Issue
4
Pages
1072-1086
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2078494086
Cited by
26
References
0
FWCI
0.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of vascular endothelial cell growth factor gene transfer to enhance implantable sensor function in vivo. https://app.cochat.ai/papers/10.1002/jbm.a.20041
The paper
Klueh, U., Dorsky, D. I., & Kreutzer, D. L. (2003). Use of vascular endothelial cell growth factor gene transfer to enhance implantable sensor function in vivo. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.20041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.