In vitro evaluation of novel bioactive composites based on Bioglass®‐filled polylactide foams for bone tissue engineering scaffolds

Blaker, J. J., Gough, J. E., Maquet, V., Notingher, I., Boccaccini, A. R.·2003·Journal of Biomedical Materials Research Part A

Abstract

Highly porous poly(DL‐lactic acid) (PDLLA) foams and Bioglass®‐filled PDLLA composite foams were characterized and evaluated in vitro as bone tissue engineering scaffolds. The hypothesis was that the combination of PDLLA with Bioglass® in a porous structure would result in a bioresorbable and bioactive composite, capable of supporting osteoblast adhesion, spreading and viability. Composite and unfilled foams were incubated in simulated body fluid (SBF) at 37°C to study the in vitro degradation of the polymer and to detect hydroxyapatite (HA) formation, which is a measure of the materials'in vitro bioactivity. HA was detected on all the composite samples after incubation in SBF for just 3 days. After 28 days immersion the foams filled with 40 wt % Bioglass® developed a continuous layer of HA. The formation of HA for the 5 wt % Bioglass®‐filled foams was localized to the Bioglass® particles. Cell culture studies using a commercially available (ECACC) human osteosarcoma cell line (MG‐63) were conducted to assess the biocompatibility of the foams and cell attachment to the porous substrates. The osteoblast cell infiltration study showed that the cells were able to migrate through the porous network and colonize the deeper regions within the foam, indicating that the composition of the foams and the pore structures are able to support osteoblast attachment, spreading, and viability. Rapid formation of HA on the composites and the attachment of MG‐63 cells within the porous network of the composite foams confirms the high in vitro bioactivity and biocompatibility of these materials and their potential to be used as scaffolds in bone tissue engineering and repair. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 1401–1411, 2003

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.20055

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 215

Metadata

Authors
Blaker, J. J., Gough, J. E., Maquet, V., Notingher, I., & Boccaccini, A. R.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2003-11-06
Volume
67A
Issue
4
Pages
1401-1411
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2122996284
Cited by
215
References
0
FWCI
7.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vitro evaluation of novel bioactive composites based on Bioglass®‐filled polylactide foams for bone tissue engineering scaffolds. https://app.cochat.ai/papers/10.1002/jbm.a.20055
The paper
Blaker, J. J., Gough, J. E., Maquet, V., Notingher, I., & Boccaccini, A. R. (2003). In vitro evaluation of novel bioactive composites based on Bioglass®‐filled polylactide foams for bone tissue engineering scaffolds. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.20055

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.