The DOI matches its Crossref record.
In vitro evaluation of novel bioactive composites based on Bioglass®‐filled polylactide foams for bone tissue engineering scaffolds
Abstract
Highly porous poly(DL‐lactic acid) (PDLLA) foams and Bioglass®‐filled PDLLA composite foams were characterized and evaluated in vitro as bone tissue engineering scaffolds. The hypothesis was that the combination of PDLLA with Bioglass® in a porous structure would result in a bioresorbable and bioactive composite, capable of supporting osteoblast adhesion, spreading and viability. Composite and unfilled foams were incubated in simulated body fluid (SBF) at 37°C to study the in vitro degradation of the polymer and to detect hydroxyapatite (HA) formation, which is a measure of the materials'in vitro bioactivity. HA was detected on all the composite samples after incubation in SBF for just 3 days. After 28 days immersion the foams filled with 40 wt % Bioglass® developed a continuous layer of HA. The formation of HA for the 5 wt % Bioglass®‐filled foams was localized to the Bioglass® particles. Cell culture studies using a commercially available (ECACC) human osteosarcoma cell line (MG‐63) were conducted to assess the biocompatibility of the foams and cell attachment to the porous substrates. The osteoblast cell infiltration study showed that the cells were able to migrate through the porous network and colonize the deeper regions within the foam, indicating that the composition of the foams and the pore structures are able to support osteoblast attachment, spreading, and viability. Rapid formation of HA on the composites and the attachment of MG‐63 cells within the porous network of the composite foams confirms the high in vitro bioactivity and biocompatibility of these materials and their potential to be used as scaffolds in bone tissue engineering and repair. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 1401–1411, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering
Rezwan, K., Chen, Q. Z., Blaker, J. J., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.039 · Cited by 3,839
Self-citationPolymeric Scaffolds in Tissue Engineering Application: A Review
Dhandayuthapani, B., Yoshida, Y., Maekawa, T., & Kumar, D. S. (2011) · International Journal of Polymer Science · doi:10.1155/2011/290602 · Cited by 1,773
New emerging trends in synthetic biodegradable polymers—Polylactide: A critique
Gupta, A. P., & Kumar, V. (2007) · European Polymer Journal · doi:10.1016/j.eurpolymj.2007.06.045 · Cited by 941
Future Prospects for Scaffolding Methods and Biomaterials in Skin Tissue Engineering: A Review
Chaudhari, A., Vig, K., Baganizi, D., Sahu, R., Dixit, S., Dennis, V., Singh, S., & Pillai, S. (2016) · International Journal of Molecular Sciences · doi:10.3390/ijms17121974 · Cited by 604
Biomaterials for Bone Regenerative Engineering
Yu, X., Tang, X., Gohil, S. V., & Laurencin, C. T. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400760 · Cited by 418
Metadata
- Authors
- Blaker, J. J., Gough, J. E., Maquet, V., Notingher, I., & Boccaccini, A. R.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-11-06
- Volume
- 67A
- Issue
- 4
- Pages
- 1401-1411
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2122996284
- Cited by
- 215
- References
- 0
- FWCI
- 7.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vitro evaluation of novel bioactive composites based on Bioglass®‐filled polylactide foams for bone tissue engineering scaffolds. https://app.cochat.ai/papers/10.1002/jbm.a.20055
- The paper
- Blaker, J. J., Gough, J. E., Maquet, V., Notingher, I., & Boccaccini, A. R. (2003). In vitro evaluation of novel bioactive composites based on Bioglass®‐filled polylactide foams for bone tissue engineering scaffolds. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.20055
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.