The DOI matches its Crossref record.
Osteochondral repair in the rabbit model utilizing bilayered, degradable oligo(poly(ethylene glycol) fumarate) hydrogel scaffolds
Abstract
In this study, hydrogel scaffolds, based on the polymer oligo(poly(ethylene glycol) fumarate) (OPF), were implanted into osteochondral defects in the rabbit model. Scaffolds consisted of two layers—a bottom, bone forming layer and a top, cartilage forming layer. Three scaffold formulations were implanted to assess how material composition and transforming growth factor‐β1 (TGF‐β1) loading affected osteochondral repair. Critical histological evaluation and scoring of the quantity and quality of tissue in the chondral and subchondral regions of defects was performed at 4 and 14 weeks. At both time points, no evidence of prolonged inflammation was observed, and healthy tissue was seen to infiltrate the defect area. The quality of this tissue improved over time with hyaline cartilage filling the chondral region and a mixture of trabecular and compact bone filling the subchondral region at 14 weeks. A promising degree of Safranin O staining and chondrocyte organization was observed in the newly formed surface tissue, while the underlying subchondral bone was completely integrated with the surrounding bone at 14 weeks. Material composition within the bottom, bone‐forming layer did not appear to affect the rate of scaffold degradation or tissue filling. However, no bone upgrowth into the chondral region was observed with any scaffold formulation. TGF‐β1 loading in the top layer of scaffolds appeared to exert some therapeutic affect on tissue quality, but further studies are necessary for scaffold optimization. Yet, the excellent tissue filling and integration resulting from osteochondral implantation of these OPF‐based scaffolds demonstrates their potential in cartilage repair strategies. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Matrices and scaffolds for delivery of bioactive molecules in bone and cartilage tissue engineering
Lee, S.-H., & Shin, H. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.016 · Cited by 706
Cell-laden hydrogels for osteochondral and cartilage tissue engineering
Yang, J., Zhang, Y. S., Yue, K., & Khademhosseini, A. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.01.036 · Cited by 652
Haines-Butterick, L., Rajagopal, K., Branco, M., Salick, D., Rughani, R., Pilarz, M., Lamm, M. S., Pochan, D. J., & Schneider, J. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0701980104 · Cited by 642
Injectable matrices and scaffolds for drug delivery in tissue engineering
Kretlow, J. D., Klouda, L., & Mikos, A. G. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.013 · Cited by 629
Self-citation
Metadata
- Authors
- Holland, T. A., Bodde, E. W. H., Baggett, L. S., Tabata, Y., Mikos, A. G., & Jansen, J. A.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-07-28
- Volume
- 75A
- Issue
- 1
- Pages
- 156-167
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2083999930
- Cited by
- 186
- References
- 0
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Osteochondral repair in the rabbit model utilizing bilayered, degradable oligo(poly(ethylene glycol) fumarate) hydrogel scaffolds. https://app.cochat.ai/papers/10.1002/jbm.a.30379
- The paper
- Holland, T. A., Bodde, E. W. H., Baggett, L. S., Tabata, Y., Mikos, A. G., & Jansen, J. A. (2005). Osteochondral repair in the rabbit model utilizing bilayered, degradable oligo(poly(ethylene glycol) fumarate) hydrogel scaffolds. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30379
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.