Chemical modification of SWNT alters in vitro cell‐SWNT interactions
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Single‐walled carbon nanotubes (SWNT) have been the focus of considerable attention as a material with extraordinary mechanical and electrical properties. SWNT have been proposed in a number of biomedical applications, including neural, bone, and dental tissue engineering. In these applications, it is clear that surrounding tissues will come into surface contact with SWNT composites, and compatibility between SWNT and host cells must be addressed. This investigation describes the gross physical and chemical effects of different SWNT preparations on in vitro cell viability and metabolic activity. Three different SWNT preparations were analyzed: as purchased (AP‐NT), purified (PUR‐NT), and functionalized with glucosamine (GA‐NT), over concentrations of 0.001–1.0% (wt/vol). With the exception of the lowest SWNT concentrations, increasing concentrations of SWNT resulted in a decrease of cell viability, which was dependent on SWNT preparation. The metabolic activity of 3T3 cells was also dependent on SWNT preparation and concentration. These investigations have shown that these SWNT preparations have significant effects on in vitro cellular function that cannot be attributed to one factor alone, but are more likely the result of several unfavorable interactions. Effects, such as destabilizing the cell membrane, soluble toxic contaminants, and limitations in mass transfer as the SWNT coalesce into sheets, may all play a role in these interactions. Using comprehensive purification processes and modifying the NT‐surface chemistry to introduce functional groups or reduce hydrophobicity or both, these interactions can be significantly improved. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O'Brien, J., Wilson, I., Orton, T., & Pognan, F. (2000) · European Journal of Biochemistry · doi:10.1046/j.1432-1327.2000.01606.x · Cited by 3,446
Cited by
Functionalized hexagonal boron nitride nanomaterials: emerging properties and applications
Weng, Q., Wang, X., Wang, X., Bando, Y., & Golberg, D. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00869g · Cited by 1,282
Biomedical applications of functionalised carbon nanotubes
Bianco, A., Kostarelos, K., Partidos, C. D., & Prato, M. (2005) · Chemical Communications · doi:10.1039/b410943k · Cited by 1,086
Carbon nanotube applications for tissue engineering
Harrison, B. S., & Atala, A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.044 · Cited by 1,068
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Direct imaging of single-walled carbon nanotubes in cells
Porter, A. E., Gass, M., Muller, K., Skepper, J. N., Midgley, P. A., & Welland, M. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.347 · Cited by 564
“SWNTs are routinely synthesized using a metal catalyst, which also has the potential to have toxic effects on cell”
Background
Metadata
- Authors
- Nimmagadda, A., Thurston, K., Nollert, M. U., & McFetridge, P. S.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-11-28
- Volume
- 76A
- Issue
- 3
- Pages
- 614-625
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1525131765
- Cited by
- 138
- References
- 1
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.