The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Thermoreversible laminin‐functionalized hydrogel for neural tissue engineering
Abstract
Traumatic injury to the central nervous system (CNS) triggers cell death and deafferentation, which may activate a cascade of cellular and network disturbances. These events often result in the formation of irregularly shaped lesions comprised of necrotic tissue and/or a fluid‐filled cavity. Tissue engineering represents a promising treatment strategy for the injured neural tissue. To facilitate minimally invasive delivery of a tissue engineered system, a thermoreversible polymer is an attractive scaffold candidate. We have developed a bioactive scaffold for neural tissue engineering by tethering laminin‐1 (LN) to methylcellulose (MC), a thermoresponsive hydrogel. The base MC chain was oxidized via sodium m‐periodate to increase MC tethering capacity. Protein immobilization was facilitated by a Schiff base reaction between primary amine groups on LN and the carbonyl groups of the oxidized MC chain. Immunoassays demonstrated tethering of LN at 1.6 ± 0.5 ng of LN per milligram of MC. Rheological measurements for different MC–LN constructs indicated MC composition‐ and MC treatment‐dependent effects on solution–gelation transition temperature. Cellular assays with primary rat cortical neurons demonstrated enhanced cell adhesion and viability on LN‐functionalized MC when compared with base and oxidized MC. This bioadhesive thermoresponsive scaffold may provide a robust delivery vehicle to injured CNS tissue for neural cell transplantation strategies. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lutolf, M. P., & Hubbell, J. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1055 · Cited by 4,551
Cited by
Design properties of hydrogel tissue-engineering scaffolds
Zhu, J., & Marchant, R. E. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.27 · Cited by 1,430
Thermoresponsive hydrogels in biomedical applications
Klouda, L., & Mikos, A. G. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.02.025 · Cited by 1,349
Thermoresponsive Polymers for Biomedical Applications
Ward, M. A., & Georgiou, T. K. (2011) · Polymers · doi:10.3390/polym3031215 · Cited by 1,158
3D printing of hydrogels: Rational design strategies and emerging biomedical applications
Li, J., Wu, C., Chu, P. K., & Gelinsky, M. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2020.100543 · Cited by 862
Biodegradable Cellulose-based Hydrogels: Design and Applications
Sannino, A., Demitri, C., & Madaghiele, M. (2009) · Materials · doi:10.3390/ma2020353 · Cited by 845
Metadata
- Authors
- Stabenfeldt, S. E., García, A. J., & LaPlaca, M. C.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2006-03-22
- Volume
- 77A
- Issue
- 4
- Pages
- 718-725
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2119845005
- Cited by
- 217
- References
- 1
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermoreversible laminin‐functionalized hydrogel for neural tissue engineering. https://app.cochat.ai/papers/10.1002/jbm.a.30638
- The paper
- Stabenfeldt, S. E., García, A. J., & LaPlaca, M. C. (2006). Thermoreversible laminin‐functionalized hydrogel for neural tissue engineering. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30638
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.