Biomechanical evaluation of the interfacial strength of a chemically modified sandblasted and acid‐etched titanium surface

Ferguson, S.J., Broggini, N., Wieland, M., de Wild, M., Rupp, F., Geis‐Gerstorfer, J., Cochran, D.L., Buser, D.·2006·Journal of Biomedical Materials Research Part A

Abstract

The functional capacity of osseointegrated dental implants to bear load is largely dependent on the quality of the interface between the bone and implant. Sandblasted and acid‐etched (SLA) surfaces have been previously shown to enhance bone apposition. In this study, the SLA has been compared with a chemically modified SLA (modSLA) surface. The increased wettability of the modSLA surface in a protein solution was verified by dynamic contact angle analysis. Using a well‐established animal model with a split‐mouth experimental design, implant removal torque testing was performed to determine the biomechanical properties of the bone–implant interface. All implants had an identical cylindrical shape with a standard thread configuration. Removal torque testing was performed after 2, 4, and 8 weeks of bone healing (n = 9 animals per healing period, three implants per surface type per animal) to evaluate the interfacial shear strength of each surface type. Results showed that the modSLA surface was more effective in enhancing the interfacial shear strength of implants in comparison with the conventional SLA surface during early stages of bone healing. Removal torque values of the modSLA‐surfaced implants were 8–21% higher than those of the SLA implants (p = 0.003). The mean removal torque values for the modSLA implants were 1.485 N m at 2 weeks, 1.709 N m at 4 weeks, and 1.345 N m at 8 weeks; and correspondingly, 1.231 N m, 1.585 N m, and 1.143 N m for the SLA implants. The bone–implant interfacial stiffness calculated from the torque–rotation curve was on average 9–14% higher for the modSLA implants when compared with the SLA implants (p = 0.038). It can be concluded that the modSLA surface achieves a better bone anchorage during early stages of bone healing than the SLA surface; chemical modification of the standard SLA surface likely enhances bone apposition and this has a beneficial effect on the interfacial shear strength. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.30678

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 202

Metadata

Authors
Ferguson, S. J., Broggini, N., Wieland, M., de Wild, M., Rupp, F., Geis‐Gerstorfer, J., Cochran, D. L., & Buser, D.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2006-04-24
Volume
78A
Issue
2
Pages
291-297
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2060994483
Cited by
202
References
1
FWCI
13.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biomechanical evaluation of the interfacial strength of a chemically modified sandblasted and acid‐etched titanium surface. https://app.cochat.ai/papers/10.1002/jbm.a.30678
The paper
Ferguson, S. J., Broggini, N., Wieland, M., de Wild, M., Rupp, F., Geis‐Gerstorfer, J., Cochran, D. L., & Buser, D. (2006). Biomechanical evaluation of the interfacial strength of a chemically modified sandblasted and acid‐etched titanium surface. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30678

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.