Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Comparison of aortic valve allograft decellularization techniques in the rat

Meyer, Steven R., Chiu, Brian, Churchill, Thomas A., Zhu, Linfu, Lakey, Jonathan R.T., Ross, David B. · 2006 · Journal of Biomedical Materials Research Part A

Abstract

Rodent models have been essential to understanding the immune‐mediated failure of aortic valve allografts (AVAs). Decellularization has been proposed to reduce the immunogenicity of AVAs. The objective of this study was to determine the most effective method to decellularize AVAs for use in a rat model. Three different decellularization techniques were compared in Lewis aortic valves. Detergent decellularization involved a series of hypotonic and hypertonic Tris buffers at 4°C for 48 h/buffer containing 0.5% Triton X‐100 followed by a 72 h washout in phosphate‐buffered saline. Osmotic decellularization was performed in similar manner to the detergent‐based technique except without the addition of Triton X‐100. Enzymatic decellularization consisted of trypsin/EDTA at 37°C for 48 h. Assessment was performed with light microscopy (H&E, Movat's pentachrome), immunohistochemistry for residual cellular elements, and hydroxyproline assays. Detergent‐based methodology effected near‐complete decellularization of both the leaflets and aortic wall in addition to preservation of the extracellular matrix (ECM). Osmotic lysis was associated with preservation of ECM and moderate decellularization. Enzymatic decellularization resulted in complete decellularization but extensive degeneration and fragmentation of the ECM. When implanted into the infrarenal aorta of allogeneic rats for 1 week, valves decellularized with detergent‐based and osmotic methodology failed to stimulate an allogeneic immune response as evidenced by an absence of T cell infiltrates. Osmotic lysis protocols with low dose detergent appear to be most effective at both removing antigenic cellular elements and preserving ECM. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.30777

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 176

Metadata

Authors
Meyer, S. R., Chiu, B., Churchill, T. A., Zhu, L., Lakey, J. R. T., & Ross, D. B.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2006-06-30
Volume
79A
Issue
2
Pages
254-262
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2111924727
Cited by
176
References
1
FWCI
4.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of aortic valve allograft decellularization techniques in the rat. https://app.cochat.ai/papers/10.1002/jbm.a.30777
The paper
Meyer, S. R., Chiu, B., Churchill, T. A., Zhu, L., Lakey, J. R. T., & Ross, D. B. (2006). Comparison of aortic valve allograft decellularization techniques in the rat. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30777

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.