The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Folic acid‐PEG conjugated superparamagnetic nanoparticles for targeted cellular uptake and detection by MRI
Abstract
We report the development and in vitro study of a nanoconjugate serving as a targeted magnetic resonance imaging (MRI) contrast enhancement agent for detection of cancer cells overexpressing the folate receptor. The nanoconjugate was synthesized by coating superparamagnetic iron oxide nanoparticles with covalently bound bifunctional poly(ethylene glycol) (PEG), followed by conjugation with folic acid (FA). The specificity of the nanoconjugate targeting cancerous cells was demonstrated by comparative intracellular uptake of the nanoconjugate and PEG‐/dextran‐coated nanoparticles by human adenocarcinoma HeLa cells. Preferential targeting to cancerous cells was studied by comparing the uptake of the nanoconjugate by HeLa cells and by non‐FR expressing osteosarcoma MG‐63 cells. Uptake of the nanoconjugate by HeLa cells after 4 h incubation was found to be a 12‐fold higher than that of PEG‐ or dextran‐coated nanoparticles as quantified by inductively coupled plasma spectroscopy. A significant negative contrast enhancement was observed with magnetic resonance (MR) phantom imaging for HeLa cells over MG‐63 cells, when both were cultured with the nanoconjugate. Specificity of the nanoconjugate for folate receptors was also verified with a competitive inhibition assay, in which HeLa cells were incubated with both NP–PEG–FA and free FA. The bifunctional PEG used has amide linkages within the PEG chains that can form interchain hydrogen bonding, leading to improved stability of the PEG coating. Self‐assembled PEG can be controlled at the molecular level and are suitable for nanoscale coatings. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
Gupta, A. K., & Gupta, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.012 · Cited by 6,771
The preparation of magnetic nanoparticles for applications in biomedicine
Tartaj, P., Morales, M. A. D. P., Veintemillas-Verdaguer, S., Gonz lez-Carre o, T., & Serna, C. J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/202 · Cited by 1,943
Targeted drug delivery via the folate receptor
Sudimack, J., & Lee, R. J. (2000) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(99)00062-9 · Cited by 1,474
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Transport of molecules in the tumor interstitium: a review.
Jain, R. K. (1987) · PubMed · Cited by 1,378
Surface modification of superparamagnetic magnetite nanoparticles and their intracellular uptake
Zhang, Y., Kohler, N., & Zhang, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00267-8 · Cited by 1,264
Self-citationJun, Y.-W., Huh, Y.-M., Choi, J.-S., Lee, J.-H., Song, H.-T., Kim, S., Yoon, S., Kim, K.-S., Shin, J.-S., Suh, J.-S., et al. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0422155 · Cited by 1,193
Superparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B., Bacon, B., Compton, C., White, D., Jacobs, P., & Lewis, J. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045
Distribution of the folate receptor GP38 in normal and malignant cell lines and tissues.
Weitman, S. D., Lark, R. H., Coney, L. R., Fort, D. W., Frasca, V., Zurawski, V. R., & Kamen, B. A. (1992) · PubMed · Cited by 1,011
In Vivo Magnetic Resonance Detection of Cancer by Using Multifunctional Magnetic Nanocrystals
Huh, Y.-M., Jun, Y.-W., Song, H.-T., Kim, S., Choi, J.-S., Lee, J.-H., Yoon, S., Kim, K.-S., Shin, J.-S., Suh, J.-S., et al. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052337c · Cited by 859
Delivery of liposomes into cultured KB cells via folate receptor-mediated endocytosis.
Lee, R. J., & Low, P. S. (1994) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)41848-5 · Cited by 692
Wilhelm, C., Billotey, C., Roger, J., Pons, J. N., Bacri, J.-C., & Gazeau, F. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00440-4 · Cited by 675
Characterization of aqueous dispersions of Fe3O4 nanoparticles and their biomedical applications
Cheng, F.-Y., Su, C.-H., Yang, Y.-S., Yeh, C.-S., Tsai, C.-Y., Wu, C.-L., Wu, M.-T., & Shieh, D.-B. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.03.016 · Cited by 668
Immunospecific ferromagnetic iron-dextran reagents for the labeling and magnetic separation of cells
Molday, R. S., & Mackenzie, D. (1982) · Journal of Immunological Methods · doi:10.1016/0022-1759(82)90007-2 · Cited by 616
Nanotechnology for the biologist
McNeil, S. E. (2005) · Journal of Leukocyte Biology · doi:10.1189/jlb.0205074 · Cited by 613
Optical and MRI Multifunctional Nanoprobe for Targeting Gliomas
Veiseh, O., Sun, C., Gunn, J., Kohler, N., Gabikian, P., Lee, D., Bhattarai, N., Ellenbogen, R., Sze, R., Hallahan, A., et al. (2005) · Nano Letters · doi:10.1021/nl0502569 · Cited by 564
Self-citationDelivery of macromolecules into living cells: a method that exploits folate receptor endocytosis.
Leamon, C. P., & Low, P. S. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.13.5572 · Cited by 554
Vitamin B12and folate in relation to the development of Alzheimer’s disease
Wang, H.-X., Wahlin, A., Basun, H., Fastbom, J., Winblad, B., & Fratiglioni, L. (2001) · Neurology · doi:10.1212/wnl.56.9.1188 · Cited by 469
Kohler, N., Fryxell, G. E., & Zhang, M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja049195r · Cited by 466
Self-citationProteins and cells on PEG immobilized silicon surfaces
Zhang, M., Desai, T., & Ferrari, M. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00026-x · Cited by 408
Self-citationTat Peptide Directs Enhanced Clearance and Hepatic Permeability of Magnetic Nanoparticles
Wunderbaldinger, P., Josephson, L., & Weissleder, R. (2002) · Bioconjugate Chemistry · doi:10.1021/bc015563u · Cited by 266
Park, E. K., Lee, S. B., & Lee, Y. M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.008 · Cited by 264
Folate-Mediated Targeting of Therapeutic and Imaging Agents to Cancers
Reddy, J. A., & Low, P. S. (1998) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v15.i6.20 · Cited by 219
The effects of iron oxides on proton relaxivity
Josephson, L., Lewis, J., Jacobs, P., Hahn, P. F., & Stark, D. D. (1988) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(88)90088-4 · Cited by 218
Preparation of ultrafine silica- and PEG-coated magnetite particles
Butterworth, M. D., Illum, L., & Davis, S. S. (2001) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/s0927-7757(00)00633-6 · Cited by 169
Kresse, M., Wagner, S., Pfefferer, D., Lawaczeck, R., Elste, V., & Semmler, W. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400209 · Cited by 161
Tiefenauer, L., Kuehne, G., & Andres, R. Y. (1993) · Bioconjugate Chemistry · doi:10.1021/bc00023a007 · Cited by 159
Polyclonal human immunoglobulin G labeled with polymeric iron oxide: antibody MR imaging.
Weissleder, R., Lee, A. S., Fischman, A. J., Reimer, P., Shen, T. T., Wilkinson, R., Callahan, R. J., & Brady, T. J. (1991) · Radiology · doi:10.1148/radiology.181.1.1887040 · Cited by 153
Specific MR imaging of human lymphocytes by monoclonal antibody‐guided dextran‐magnetite particles
Bulte, J. W. M., Hoekstra, Y., Kamman, R. L., Magin, R. L., WEBB, A. G., Briggs, R. W., Go, K. G., Hulstaert, C. E., Miltenyi, S., THE, T. H., et al. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250115 · Cited by 147
Zhang, Y., Sun, C., Kohler, N., & Zhang, M. (2004) · Biomedical Microdevices · doi:10.1023/b:bmmd.0000013363.77466.63 · Cited by 105
Self-citationCerdán, S., Lötscher, H. R., Künnecke, B., & Seelig, J. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910120202 · Cited by 98
Zhang, S. F., Rolfe, P., Wright, G., Lian, W., Milling, A. J., Tanaka, S., & Ishihara, K. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00174-9 · Cited by 93
Preparation and Tumor Cell Uptake of Poly(N-isopropylacrylamide) Folate Conjugates
Dubé, D., Francis, M. F., Leroux, J., & Winnik, F. M. (2002) · Bioconjugate Chemistry · doi:10.1021/bc010084g · Cited by 83
The folate receptor as a potential therapeutic anticancer target
Gruner, B. A., & Weitman, S. D. (1998) · Investigational New Drugs · doi:10.1023/a:1006147932159 · Cited by 61
Drug targeting in magnetic resonance imaging.
Weissleder, R., Bogdanov, A. A., Jr., & Papisov, M. I. (1992) · PubMed · Cited by 39
(1989) · PubMed
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Magnetic nanoparticles in MR imaging and drug delivery
Sun, C., Lee, J. S. H., & Zhang, M. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.018 · Cited by 2,594
Self-citationReddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging
Veiseh, O., Gunn, J. W., & Zhang, M. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.002 · Cited by 1,832
Self-citationSuperparamagnetic iron oxide nanoparticles: magnetic nanoplatforms as drug carriers
Wahajuddin, & Arora (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s30320 · Cited by 1,117
Metadata
- Authors
- Sun, C., Sze, R., & Zhang, M.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2006-05-30
- Volume
- 78A
- Issue
- 3
- Pages
- 550-557
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1990585331
- Cited by
- 373
- References
- 36
- FWCI
- 11.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.