Self‐assembled thermosensitive micelles based on poly(L‐lactide‐star block‐N‐isopropylacrylamide) for drug delivery
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A novel seven‐arm star block copolymer poly(L‐lactide‐star block‐N‐isopropylacrylamide) (PLLA‐sb‐PNIPAAm), comprised of a hydrophobic poly(L‐lactide) (PLLA) arm and an average of six hydrophilic poly(N‐isopropylacrylamide) (PNIPAAm) arms, was designed and synthesized. The amphiphilic PLLA‐sb‐PNIPAAm copolymer was capable of self‐assembling into nano‐sized micelle in water, which was confirmed by FT‐IR, 1 H NMR and fluorescence spectroscopy. Transmission electron microscopy images showed that these nano‐sized micelles were regularly spherical in shape. Micelle size determined by size analysis was around 100 nm in diameter. The micelles showed reversible dispersion/aggregation in response to temperature changes through an outer polymer shell of PNIPAAm at around 31°C, observed by optical absorbance measurements. The anticancer drug methotrexate (MTX) as model drug was loaded in the polymeric nano‐sized micelles. In vitro release behavior of MTX was investigated, which showed a drastic thermoresponsive fast/slow switching behavior according to the temperature‐responsive structural changes of a micellar shell structure. The reversible and sensitive thermoresponse of this micelle might provide opportunities to construct a novel drug delivery system in conjunction with localized hyperthermia. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chung, J. E., Yokoyama, M., Yamato, M., Aoyagi, T., Sakurai, Y., & Okano, T. (1999) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00029-2 · Cited by 599
Kohori, F., Sakai, K., Aoyagi, T., Yokoyama, M., Sakurai, Y., & Okano, T. (1998) · Journal of Controlled Release · doi:10.1016/s0168-3659(98)00023-6 · Cited by 273
Cited by
Hydrogel nanoparticles in drug delivery
Hamidi, M., Azadi, A., & Rafiei, P. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.08.002 · Cited by 2,067
Thermoresponsive Polymers for Biomedical Applications
Ward, M. A., & Georgiou, T. K. (2011) · Polymers · doi:10.3390/polym3031215 · Cited by 1,158
Stimuli-Responsive Polymersomes for Programmed Drug Delivery
Meng, F., Zhong, Z., & Feijen, J. (2009) · Biomacromolecules · doi:10.1021/bm801127d · Cited by 1,122
Ren, J. M., McKenzie, T. G., Fu, Q., Wong, E. H. H., Xu, J., An, Z., Shanmugam, S., Davis, T. P., Boyer, C., & Qiao, G. G. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00008 · Cited by 839
Studies on thermoresponsive polymers: Phase behaviour, drug delivery and biomedical applications
Gandhi, A., Paul, A., Sen, S. O., & Sen, K. K. (2015) · Asian Journal of Pharmaceutical Sciences · doi:10.1016/j.ajps.2014.08.010 · Cited by 506
Metadata
- Authors
- Wei, H., Zhang, X., Chen, W., Cheng, S., & Zhuo, R.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-06-21
- Volume
- 83A
- Issue
- 4
- Pages
- 980-989
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1969208731
- Cited by
- 56
- References
- 2
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.